全髋关节置换翻修术治疗假体周围髋部骨折时模块化凹槽锥形柄下沉的危险因素
本研究回顾了61例Vancouver B2和B3型假体周围髋部骨折,采用非骨水泥模块化凹槽锥形柄治疗。5年无再手术生存率为89%,无假体翻修生存率为93%。8例(13%)发生柄下沉,平均18±8毫米;下沉与Dorr C型股骨(50% vs 7%,95%CI 9%-72%,P=0.007)和支撑植骨(50% vs 9%,95%CI 6%-70%,P=0.01)相关,但所有下沉均稳定无需翻修,且未导致更差临床结局。
要点
- 5年无再手术生存率89%,无假体翻修生存率93%。
- 8例(13%)出现柄下沉,平均18±8毫米,均稳定无需翻修。
- Dorr C型股骨和支撑植骨与柄下沉相关,但下沉未影响临床结局。
核心结论
- 模块化凹槽锥形柄用于治疗Vancouver B2和B3型假体周围股骨骨折时,无再手术和无假体翻修生存率优良。
- 骨形态差和使用支撑植骨(两者均提示骨储备受损和远端骨折模式)与柄下沉相关。
- 所有下沉的柄均稳定,且所观察到的下沉并未预示更差的临床结局。
研究设计与样本
- 回顾性队列研究(证据等级III),纳入61例Vancouver B2和B3型假体周围髋部骨折,采用非骨水泥模块化凹槽锥形柄治疗。
- 手术时平均年龄72岁,平均体重指数30,平均随访4.5年(范围2-10年)。
主要发现
- 5年无再手术生存率为89%,无假体翻修生存率为93%。
- 8例(13%)柄下沉,平均距离18±8毫米(范围8-28毫米)。
- 柄下沉与年龄、性别、Vancouver骨折分类、柄跨越、柄长度或柄直径无相关性。
- 柄下沉与Dorr C型股骨相关(50% vs 7%,95%CI 9%-72%;P=0.007),与支撑植骨相关(50% vs 9%,95%CI 6%-70%;P=0.01)。
- 所有下沉病例均稳定无需翻修;下沉与骨不连、再手术、翻修或临床结局无相关性。
关键数值与推荐
- 5年无再手术生存率89%,无假体翻修生存率93%。
- 柄下沉发生率13%(8/61),平均下沉距离18±8毫米(范围8-28毫米)。
- Dorr C型股骨组下沉率50% vs 非Dorr C型组7%(95%CI 9%-72%;P=0.007)。
- 支撑植骨组下沉率50% vs 未支撑植骨组9%(95%CI 6%-70%;P=0.01)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The objective of this study was to review Vancouver B2 and B3 periprosthetic hip fractures treated with uncemented modular fluted tapered stems to analyze survivorship, risk factors for stem subsidence, and clinical outcomes. METHODS: We identified 61 Vancouver B2 and B3 periprosthetic hip fractures treated with modular fluted tapered implants. Survivorship, radiographic outcomes, and clinical outcomes were assessed. The mean age at the time of surgery was 72 years, mean body mass index was 30, and mean follow-up was 4.5 years (range, 2-10 years). RESULTS: Survivorship free of reoperation or implant revision at 5 years was 89% and 93%, respectively. Eight (13%) stems subsided a mean distance of 18 ± 8 mm (range, 8-28 mm). Stem subsidence was not correlated with age, gender, Vancouver fracture classification, stem bypass, stem length, or stem diameter. Subsidence was correlated with Dorr C type femora (50% vs 7%, 95% confidence interval 9%-72%; P = .007) and strut grafting (50% vs 9%, 95% confidence interval 6%-70%; P = .01). All cases of subsidence stabilized without revision. Subsidence was not correlated with nonunion, reoperation, revision, or a clinical outcome. CONCLUSIONS: Modular fluted tapered stems had excellent survivorship free of reoperation and implant revision when used for the treatment of Vancouver B2 and B3 periprosthetic femur fractures. Poor bone morphology and the use of strut grafts, both proxies for compromised bone stock and distal fracture patterns, were correlated with stem subsidence. All subsided stems stabilized, and noted subsidence did not portend a worse clinical outcome. LEVEL OF EVIDENCE: Level III, retrospective cohort.
引用
- Parry JA, Hernandez NM, Berry DJ, et al. Risk Factors for Subsidence of Modular Fluted Tapered Stems Used During Revision Total Hip Arthroplasty for Periprosthetic Hip Fractures. J Arthroplasty. 2018. PMID: 29859724. doi:10.1016/j.arth.2018.05.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。