文献速递关节外科

小梁金属垫块重建Paprosky IIIA与IIIB型髋臼骨缺损的多中心研究结果

Results of trabecular metal augments in Paprosky IIIA and IIIB defects: A multicentre study.
PubMed 文献 · Bone Joint J · 2018-01-01

该多中心回顾性研究纳入41例因Paprosky IIIA或IIIB型髋臼骨缺损行翻修全髋关节置换术并使用小梁金属垫块与杯壳的患者,平均随访39.4个月,无翻修失败,末次随访假体存留率为100%,作者认为短期与中期结果令人鼓舞。

要点

  • 41例Paprosky IIIA或IIIB型髋臼骨缺损患者使用小梁金属垫块重建,平均随访39.4个月无失败。
  • 末次随访假体存留率为100%。
  • 作者认为小梁金属垫块用于Paprosky IIIA和IIIB型缺损的短期与中期结果令人鼓舞。

核心结论

  • 作者认为该多中心研究显示小梁金属垫块用于Paprosky IIIA和IIIB型髋臼骨缺损的短期与中期结果令人鼓舞。

研究设计与样本

  • 多中心回顾性研究,于2008年8月至2015年1月在四家中心开展。
  • 纳入使用小梁金属垫块与杯壳重建Paprosky IIIA或IIIB型缺损、无骨盆不连续且行翻修髋关节置换的患者,共41例,至少随访两年,采用意向性治疗分析。

主要发现

  • 36例(87.8%)为Paprosky IIIA型缺损,5例(12.2%)为IIIB型缺损。
  • 平均年龄56.7岁(范围28至94岁),女性21例(51.2%),男性20例(48.8%)。
  • 平均随访39.4个月(范围12至96个月),1例(2%)患者在8年后死亡。
  • 本组无翻修失败,末次随访平均假体存留率为100%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The advent of trabecular metal (TM) augments has revolutionized the management of severe bone defects during acetabular reconstruction. The purpose of this study was to evaluate patients undergoing revision total hip arthroplasty (THA) with the use of TM augments for reconstruction of Paprosky IIIA and IIIB defects. PATIENTS AND METHODS: A retrospective study was conducted at four centres between August 2008 and January 2015. Patients treated with TM augments and TM shell for a Paprosky grade IIIA or IIIB defect, in the absence of pelvic discontinuity, and who underwent revision hip arthroplasty with the use of TM augments were included in the study. A total of 41 patients with minimum follow-up of two years were included and evaluated using intention-to-treat analysis. RESULTS: There were 36 (87.8%) patients with a Paprosky IIIA defect and five (12.2%) patients with a Paprosky IIIB defect. The mean age was 56.7 years (28 to 94). There were 21 (51.2%) women and 20 (48.8%) men. The mean follow-up was 39.4 months (12 to 96). One (2%) patient died after eight years. No failures were noted in the series. The mean survivorship was 100% at the time of latest follow-up. CONCLUSION: The results of this multicentre study showed encouraging short- and mid-term results for the use of TM augments in the management of Paprosky grade IIIA and IIIB defects. Cite this article: Bone Joint J 2018;100-B:903-8.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Eachempati KK, Malhotra R, Pichai S, et al. Results of trabecular metal augments in Paprosky IIIA and IIIB defects: A multicentre study. Bone Joint J. 2018. PMID: 29954197. doi:10.1302/0301-620X.100B7.BJJ-2017-1604.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。