使用Kerboull髋臼加强装置翻修全髋关节置换术治疗累及髋臼下缘的Paprosky III型缺损:至少五年随访研究
这项回顾性研究评估了36例(37髋)Paprosky III型髋臼缺损且髋臼下缘破坏的患者,采用Kerboull髋臼加强装置、新鲜冷冻股骨头同种异体骨及髋臼下缘重建行翻修全髋关节置换术。平均随访8.2年,Merle d'Aubigné评分从术前12.5升至16.5(p<0.0001),十年无菌性松动为终点的生存率为95.3%,放射学松动为终点的生存率为76.5%,髋臼假体迁移率为21.6%。
要点
- Paprosky III型缺损伴髋臼下缘破坏者,采用Kerboull髋臼加强装置联合下缘重建,中期临床结果可接受。
- 平均随访8.2年,Merle d'Aubigné评分从术前12.5升至16.5(p<0.0001)。
- 十年生存率:无菌性松动为终点95.3%(95%CI 86.4至100),放射学松动为终点76.5%(95%CI 57.0至95.9);髋臼假体迁移率21.6%。
核心结论
- 使用Kerboull髋臼加强装置联合髋臼下缘重建行翻修全髋关节置换术,在中期随访中临床结果和生存率可接受,但髋臼假体迁移率高达21.6%。
研究设计与样本
- 回顾性研究,纳入36例(37髋)Paprosky III型髋臼缺损且髋臼下缘破坏、采用Kerboull髋臼加强装置、新鲜冷冻股骨头同种异体骨及髋臼下缘重建行翻修全髋关节置换术的患者。
主要发现
- 平均随访8.2年(5至19.3年),平均Merle d'Aubigné评分从术前12.5(5至18)升至16.5(10至18)(p<0.0001)。
- 以无菌性松动为终点的十年生存率为95.3%(标准差4.5;95%CI 86.4至100)。
- 以放射学松动为终点的十年生存率为76.5%(标准差9.9;95%CI 57.0至95.9)。
- 髋臼假体迁移率为21.6%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The purpose of this retrospective study was to evaluate the minimum five-year outcome of revision total hip arthroplasty (THA) using the Kerboull acetabular reinforcement device (KARD) in patients with Paprosky type III acetabular defects and destruction of the inferior margin of the acetabulum. PATIENTS AND METHODS: We identified 36 patients (37 hips) who underwent revision THA under these circumstances using the KARD, fresh frozen allograft femoral heads, and reconstruction of the inferior margin of the acetabulum. The Merle d'Aubigné system was used for clinical assessment. Serial anteroposterior pelvic radiographs were used to assess migration of the acetabular component. RESULTS: At a mean follow-up of 8.2 years (5 to 19.3), the mean Merle d'Aubigné score increased from 12.5 (5 to 18) preoperatively to 16.5 (10 to 18) (p < 0.0001). The survival rate at ten years was 95.3% (sd 4.5; 95% confidence interval (CI) 86.4 to 100) and 76.5% (sd 9.9, 95% CI 57.0 to 95.9) using aseptic loosening and radiological loosening as the endpoints, respectively. CONCLUSION: These results show that the use of the KARD with reconstruction of the inferior margin of the acetabulum in revision THA is associated with acceptable clinical results and survival at mid-term follow-up with, however, a high rate of migration of the acetabular component of 21.6%. Cite this article: Bone Joint J 2018;100-B:725-32.
引用
- Gibon E, Barut N, Courpied JP, et al. Revision total hip arthroplasty using the Kerboull acetabular reinforcement device for Paprosky type III defects involving the inferior margin of the acetabulum: a minimum five-year follow-up study. Bone Joint J. 2018. PMID: 29855248. doi:10.1302/0301-620X.100B6.BJJ-2017-1472.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。