文献速递关节外科

全膝关节置换术后僵硬采用流程化翻修改善活动度与临床结局

Protocol-Driven Revision for Stiffness After Total Knee Arthroplasty Improves Motion and Clinical Outcomes.
PubMed 文献 · J Arthroplasty · 2018-05-30

回顾性纳入69例全膝关节置换术后僵硬行翻修手术的连续患者,按假体处理方式分组。翻修术后屈曲挛缩、屈曲度、活动弧及KSS膝评分和功能评分均显著改善;全部假体翻修组活动弧改善幅度最大。

要点

  • 翻修术后平均屈曲挛缩从17°改善至5°,屈曲度从70°改善至92°,活动弧从53°改善至87°(P<.001)。
  • KSS膝评分从42改善至70,功能评分从41改善至68(P<.001)。
  • 全部假体翻修组活动弧改善45°,保留假体组32°,单一假体翻修组29°(P=.046)。

核心结论

  • 翻修手术伴或不伴假体翻修均可改善全膝关节置换术后僵硬患者的活动度与功能。
  • 在适当选择的患者中,全部假体翻修可能在这些结局指标上提供最大改善。

研究设计与样本

  • 回顾性识别连续行翻修全膝关节置换术的患者,纳入仅行清创和聚乙烯衬垫更换、仅翻修股骨或胫骨固定假体之一、或翻修全部假体的患者。
  • 共纳入69膝,平均随访43个月(范围12-205个月)。

主要发现

  • 翻修术前平均屈曲挛缩17°改善至术后5°(P<.001)。
  • 平均屈曲度从70°改善至92°,活动弧从53°改善至87°(P<.001)。
  • 平均KSS膝评分从42改善至70,KSS功能评分从41改善至68(P<.001)。
  • 全部假体翻修组活动弧平均改善45°,保留假体组改善32°,单一假体翻修组改善29°(P=.046)。
  • 上述三组KSS膝评分分别改善34分、25分、28分(P=.049);KSS功能评分分别改善33分、27分、25分(P=.077)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stiffness after revision total knee arthroplasty (TKA) is a difficult problem without a well-defined treatment algorithm. The purpose of this study was to evaluate the results of revision TKA for stiffness within the context of differential component replacement. METHODS: Consecutive patients who underwent revision TKA were retrospectively identified and included those who received debridement and polyethylene liner exchange alone, revision of only one of the femoral or tibial fixed components, or revision of all components. Preoperative and postoperative range of motion and Knee Society score (KSS) were collected. RESULTS: Sixty-nine knees were included in the study group with a mean follow-up of 43 months (range, 12-205 months). The mean prerevision flexion contracture of 17° improved to 5° after surgical intervention (P < .001). Similarly, mean flexion and motion arc improved from 70° to 92° and from 53° to 87°, respectively (P < .001). Mean KSS knee scores improved from 42 to 70 and KSS function scores improved from 41 to 68 (P < .001). Mean arc of motion improved by 45° in patients who underwent complete component revision, 32° with component retention, and 29° with single component revision (P = .046). KSS knee scores improved by 34, 25, and 28 points in these respective groups (P = .049). KSS function scores improved by 33, 27, and 25 points (P = .077). CONCLUSION: Revision surgery with or without component revision can improve motion and function in patients with stiffness after TKA. Complete component revision may offer the largest improvements in these outcome measures in properly selected patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hug KT, Amanatullah DF, Huddleston JI, et al. Protocol-Driven Revision for Stiffness After Total Knee Arthroplasty Improves Motion and Clinical Outcomes. J Arthroplasty. 2018. PMID: 29859726. doi:10.1016/j.arth.2018.05.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。