文献速递关节外科创伤骨科

细胞计数分析在假体周围关节感染诊断中的可靠性如何?

How Reliable Is the Cell Count Analysis in the Diagnosis of Prosthetic Joint Infection?
PubMed 文献 · J Arthroplasty · 2018-05-17

该单中心回顾性分析纳入524例术前关节穿刺(255髋、269膝),评估白细胞计数与多形核细胞百分比诊断假体周围关节感染的准确性。337例(64.3%)可测得细胞计数,全体最佳阈值为2582个白细胞/μL(敏感度80.6%、特异度85.2%)和PMN% 66.1%(敏感度80.6%、特异度83.3%),全膝关节与全髋关节置换的阈值存在差异。作者认为细胞计数和PMN%是敏感方法,但现行国际指南和诊断标准需修订。

要点

  • 全体患者诊断PJI的最佳阈值为2582个白细胞/μL(敏感度80.6%、特异度85.2%)。
  • 全膝关节置换的阈值为1630个白细胞/μL(敏感度83.6%、特异度82.2%),PMN% 60.5%(敏感度80.3%、特异度77.1%)。
  • 全髋关节置换的阈值为3063个白细胞/μL(敏感度78.1%、特异度80.0%),PMN% 66.1%(敏感度82.2%、特异度82.4%)。

核心结论

  • 细胞计数和多形核细胞百分比是诊断全髋和全膝关节置换术后假体周围关节感染的敏感方法。
  • 膝关节与髋关节之间的阈值存在差异。
  • 国际指南和诊断标准需要针对这些参数进行修订。

研究设计与样本

  • 单中心回顾性分析,纳入524例术前关节穿刺(255髋、269膝)的临床数据。
  • 检测滑液的白细胞酯酶活性、白细胞计数和多形核细胞百分比,并送需氧和厌氧细菌培养。
  • 依据肌肉骨骼感染学会假体周围关节感染标准,203例因无菌性翻修入院,134例因感染性翻修入院。

主要发现

  • 337例(占研究患者的64.3%)能够测得细胞计数。
  • 全体患者诊断PJI的最佳阈值为2582个白细胞/μL(敏感度80.6%、特异度85.2%)和PMN% 66.1%(敏感度80.6%、特异度83.3%)。
  • 全膝关节置换的阈值为1630个白细胞/μL(敏感度83.6%、特异度82.2%)和PMN% 60.5%(敏感度80.3%、特异度77.1%)。
  • 全髋关节置换的阈值为3063个白细胞/μL(敏感度78.1%、特异度80.0%)和PMN% 66.1%(敏感度82.2%、特异度82.4%)。

关键数值与推荐

  • 全体患者PJI诊断阈值:白细胞计数2582个/μL(敏感度80.6%、特异度85.2%),PMN% 66.1%(敏感度80.6%、特异度83.3%)。
  • 全膝关节置换PJI诊断阈值:白细胞计数1630个/μL(敏感度83.6%、特异度82.2%),PMN% 60.5%(敏感度80.3%、特异度77.1%)。
  • 全髋关节置换PJI诊断阈值:白细胞计数3063个/μL(敏感度78.1%、特异度80.0%),PMN% 66.1%(敏感度82.2%、特异度82.4%)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Synovial analysis of joint aspirates is a key diagnostic tool; all major diagnostic algorithms include cell count (CC) and polymorphonuclear percentage (PMN%) as important criteria to make the diagnosis. In this context, we conducted this study to analyze the overall accuracy of CC and PMN%. METHODS: A single-center retrospective analysis was performed with clinical data of included patients, with a total of 524 preoperative joint aspirations (255 hips, 269 knees). From the aspirated synovial fluid, we tested the leukocyte esterase activity, leukocyte CC, and PMN%, and sent specimens for aerobic and anaerobic bacterial culture. Depending on the clinical results in accordance with the Musculoskeletal Infection Society criteria for prosthetic joint infection (PJI), 203 patients were then admitted for aseptic revision and 134 patients for septic exchange. RESULTS: In 337 cases (64.3% of the study patients), it was possible to measure the CC. The best cutoff level for PJI of all study patients was 2582 leukocytes/μL (sensitivity [SE] 80.6%, specificity [SP] 85.2%) and a PMN% of 66.1% (SE 80.6%, SP 83.3%). The chosen cutoff levels for PJI of total knee and total hip arthroplasty were 1630 leukocytes/μL (SE 83.6%, SP 82.2%) and a PMN% of 60.5% (SE 80.3%, SP 77.1%) and 3063 leukocytes/μL (SE 78.1%, SP 80.0%) and a PMN% of 66.1% (SE 82.2%, SP 82.4%), respectively. CONCLUSIONS: CC and PMN% are sensitive methods for diagnosing PJI of total hip and total knee arthroplasty. However, there are differences in cutoff levels between knees and hips. International guidelines and diagnostic criteria need revisions in terms of these parameters.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Zahar A, Lausmann C, Cavalheiro C, et al. How Reliable Is the Cell Count Analysis in the Diagnosis of Prosthetic Joint Infection? J Arthroplasty. 2018. PMID: 29887359. doi:10.1016/j.arth.2018.05.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。