文献速递关节外科

常规膝关节X线片评估假体位置是否足够可靠

Is Regular Knee Radiograph Reliable Enough to Assess the Knee Prosthesis Position?
PubMed 文献 · J Arthroplasty · 2018-05-30

该回顾性横断面研究纳入88例患者共100张膝关节假体X线片,比较常规站立膝关节X线片(RR)与3英尺站立全长X线片(LR)评估冠状面假体位置的准确性。RR较LR高估股骨假体角1.3°、胫股角1.4°,胫骨假体角无显著差异;作者认为RR高估幅度小,可作为LR的可接受替代。

要点

  • RR较LR高估股骨假体角1.3°(95%CI 0.9°-1.6°,P<.001)。
  • RR较LR高估胫股角1.4°(95%CI 1.0°-1.9°,P<.001)。
  • 胫骨假体角两技术相似,平均差0.2°(95%CI 0°-0.4°,P=.11)。

核心结论

  • RR对股骨假体角和胫股角的高估幅度小,提示RR可作为LR的可接受替代。

研究设计与样本

  • 回顾性横断面研究,纳入88例膝关节假体患者的100张膝关节X线片。
  • 使用图像存档与通信系统制作数字化X线片并测量角度,将LR图像裁剪至与RR相同尺寸以消除旋转误差。
  • 测量股骨假体角、胫骨假体角和胫股角,采用Student t检验分析,Pearson相关系数评估观察者间和观察者内信度。

主要发现

  • RR较LR股骨假体角平均增加1.3°(95%CI 0.9°-1.6°,P<.001)。
  • RR较LR胫股角平均增加1.4°(95%CI 1.0°-1.9°,P<.001)。
  • 胫骨假体角两技术相似,平均差0.2°(95%CI 0°-0.4°,P=.11)。
  • RR对股骨假体角和胫骨假体角提供很强的观察者内可重复性,但观察者间信度仅为强;LR对所有角度提供很强相关性。

临床怎么用

  • 作者认为RR可作为LR的可接受替代。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Proper knee alignment and prosthesis position may theoretically provide better surgical results and increase longevity of total knee arthroplasty. The 3-feet standing long radiograph (LR) is the gold standard for assessment of these parameters. However, the conventional standing regular knee radiograph (RR) is still being used because of convenience and lower cost. We conducted a study to investigate the accuracy of RR compared to LR in assessing the coronal plane prosthesis position. METHODS: We conducted a retrospective cross-sectional study in 100 knee radiographs in 88 patients with knee prostheses. The picture archiving and communications system was used to produce digitized radiographs and perform the angle measurements. LR images were cropped to the same size as the RRs to eradicate rotation error. The femoral component angle (FCA), tibial component angle (TCA), and tibiofemoral angle (TFA) were measured and analyzed by Student t-test. Pearson's correlation coefficient was used to assess interobserver and intraobserver reliability. RESULTS: The RR measurements resulted in a mean increment of 1.3° (95% confidence interval [CI], 0.9°-1.6°; P < .001) for FCA and 1.4° (95% CI, 1.0°-1.9°; P < .001) for TFA compared to LR. The TCAs were similar between 2 techniques (0.2° mean difference; 95% CI, 0°-0.4°; P = .11). RR provided very strong intraobserver reproducibility but only strong interobserver reliability for FCA and TCA while LR provided very strong correlation for all angles. CONCLUSION: RR overestimation of FCA and TFAs in a valgus alignment was minimal, suggesting RR could be an acceptable alternative to LR.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tammachote N, Kriengburapha N, Chaiwuttisak A, et al. Is Regular Knee Radiograph Reliable Enough to Assess the Knee Prosthesis Position? J Arthroplasty. 2018. PMID: 29859725. doi:10.1016/j.arth.2018.05.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。