文献速递脊柱外科小儿骨科

脑瘫儿童脊柱侧凸骨盆固定的三种方法:5年随访差异

Three Methods of Pelvic Fixation for Scoliosis in Children With Cerebral Palsy: Differences at 5-year Follow-Up.
PubMed 文献 · Spine (Phila Pa 1976) · 2019-01-01

多中心回顾性研究纳入70例脑瘫脊柱侧凸患儿,比较单元棒(9例)、骶-翼-髂螺钉(19例)与髂螺钉(42例)骨盆固定术后及5年随访的骨盆倾斜与主弯矫正,发现三组术后骨盆倾斜均显著改善并维持至5年,但髂螺钉组5年骨盆倾斜(12°)显著高于单元棒组(4°)和骶-翼-髂螺钉组(6°),且植入物相关并发症最多。

要点

  • 单元棒、骶-翼-髂螺钉和髂螺钉三种骨盆固定术后骨盆倾斜均显著改善并维持至5年。
  • 5年随访时髂螺钉组骨盆倾斜12°显著高于单元棒组4°(P=0.001)和骶-翼-髂螺钉组6°(P=0.006)。
  • 髂螺钉组植入物相关并发症6例,包括3例棒与髂螺钉连接丢失、2例螺钉突出和1例螺钉松动。

核心结论

  • 单元棒、骶-翼-髂螺钉和髂螺钉均可实现脑瘫相关脊柱侧凸患儿术后骨盆倾斜矫正。
  • 植入物相关并发症和再手术在髂螺钉组最常见。
  • 5年随访时髂螺钉组出现主弯矫正丢失,且骨盆倾斜矫正不如单元棒组和骶-翼-髂螺钉组。

研究设计与样本

  • 回顾性综述。
  • 多中心回顾纳入70例脑瘫脊柱侧凸患儿,行后路脊柱融合骨盆固定,单元棒组9例、骶-翼-髂螺钉组19例、髂螺钉组42例。
  • 纳入标准为年龄小于18岁且随访5年。
  • 比较术前、术后(首次直立)和5年随访X线片的骨盆倾斜和主冠状弯测量,记录植入物相关并发症,Alpha=0.05。

主要发现

  • 所有组术前与术后骨盆倾斜差异显著,并维持至5年。
  • 5年随访时骨盆倾斜髂螺钉组12°显著高于单元棒组4°(P=0.001)和骶-翼-髂螺钉组6°(P=0.006)。
  • 植入物相关并发症:单元棒组1例(再手术),骶-翼-髂螺钉组无,髂螺钉组6例,包括3例棒与髂螺钉连接丢失、2例螺钉突出和1例螺钉松动。

关键数值与推荐

  • 5年随访骨盆倾斜:单元棒组4°,骶-翼-髂螺钉组6°,髂螺钉组12°。
  • 5年随访骨盆倾斜髂螺钉组 vs 单元棒组 P=0.001,髂螺钉组 vs 骶-翼-髂螺钉组 P=0.006。
  • 植入物相关并发症例数:单元棒组1例,骶-翼-髂螺钉组0例,髂螺钉组6例。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: A retrospective review. OBJECTIVE: The aim of this study was to assess correction of pelvic obliquity in children with cerebral palsy (CP) scoliosis postoperatively and 5 years after posterior spinal fusion with pelvic fixation using unit rods, sacral-alar-iliac (SAI) screws, or iliac screws. SUMMARY OF BACKGROUND DATA: There are multiple options for pelvic fixation in children with scoliosis secondary to CP. The long-term differences in outcomes between these fixation methods are still unclear. METHODS: A multicenter review identified records of 70 children with CP who underwent posterior spinal fusion for scoliosis using unit rods (n = 9), SAI screws (n = 19), or iliac screws (n = 42). Patients younger than 18 years with 5-year follow-up were included. Pelvic obliquity and major coronal curve measurements were compared using preoperative, (first erect) postoperative, and 5-year follow-up radiographs. Implant-related complications were noted. Alpha = 0.05. RESULTS: For all groups, there was a significant difference between preoperative and postoperative pelvic obliquity that was maintained at 5 years. At 5-year follow-up, pelvic obliquity was significantly higher in the IS group (12°) compared with the unit rod group (4°, P = 0.001) and SAI screw group (6°) (P = 0.006). Implant-related complications were as follows: unit rod group, one patient (reoperation); SAI screw group, none; iliac screw group, six patients, including three cases of loss of connection between the rod and the iliac screw, two prominent screws, and one loose screw. CONCLUSION: Correction of pelvic obliquity for children with CP-related scoliosis was achieved postoperatively using unit rods, SAI screws, and iliac screws. Implant-related complications and reoperations were most common in the iliac screw group. At 5-year follow-up, the iliac screw group had loss of major curve correction and less correction of pelvic obliquity than the unit rod and SAI screw groups. LEVEL OF EVIDENCE: 3.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Abousamra O, Sullivan BT, Samdani AF, et al. Three Methods of Pelvic Fixation for Scoliosis in Children With Cerebral Palsy: Differences at 5-year Follow-Up. Spine (Phila Pa 1976). 2019. PMID: 29939974. doi:10.1097/BRS.0000000000002761