文献速递运动医学关节外科

用于前交叉韧带重建的跟腱同种异体移植物变异性如何?一项生物力学研究

How Variable Are Achilles Allografts Used for Anterior Cruciate Ligament Reconstruction? A Biomechanical Study.
PubMed 文献 · Am J Sports Med · 2018-05-09

研究从单家医院前交叉韧带重建术中使用的全跟腱同种异体移植物残留物中采集15例完整外侧三分之一跟腱标本,均来自单一组织库并接受低剂量伽马辐照(1.5-2.5 Mrad)灭菌。生物力学测试显示最大应力12.2±4.1 MPa、最大应变21.0%±6.3%、弹性模量95.5±30.8 MPa,对应变异系数分别为34%、30%、32%;循环测试中肌腱伸长平均1.4%±1.6%,变异系数118%。供者年龄和失败位置与材料属性无显著相关。

要点

  • 跟腱同种异体移植物在循环载荷下伸长变异系数达118%,材料属性变异系数30%-34%。
  • 最大应力12.2±4.1 MPa、最大应变21.0%±6.3%、弹性模量95.5±30.8 MPa。
  • 供者年龄与移植物循环伸长或失败测试材料属性无相关性。

核心结论

  • 用于前交叉韧带重建的跟腱同种异体移植物在循环载荷下的移植物伸长和材料属性变异范围落在文献报道的其他前交叉韧带重建同种异体移植物属性范围内。
  • 材料属性不因供者年龄或失败测试中观察到的移植物失败位置而不同。

研究设计与样本

  • 描述性实验室研究,共采集15例完整的外侧三分之一跟腱同种异体移植物标本,来自单家医院术中前交叉韧带重建使用的全跟腱同种异体移植物残留物。
  • 所有移植物来自单一组织库,接受专有消毒和低剂量伽马辐照(1.5-2.5 Mrad)。
  • 进行生物力学测试测量肌腱伸长、拉伸测试中的失败位置、最大应力、最大应变和弹性模量,计算各指标的均值和标准差,用变异系数(CV)计算标本间变异性,用线性回归检验供者年龄对移植物材料属性的影响,用单因素方差分析比较不同失败位置间的力学属性差异。

主要发现

  • 循环测试中肌腱伸长平均1.4%±1.6%,变异系数118%。
  • 失败测试中最大应力平均12.2±4.1 MPa,最大应变平均21.0%±6.3%,弹性模量平均95.5±30.8 MPa。
  • 最大应力、最大应变和弹性模量的变异系数分别为34%、30%和32%。
  • 10条肌腱在中段失败,5条在肌腱-骨附着处失败。
  • 中段失败与附着处失败的移植物之间力学属性无差异。

临床怎么用

  • 作者指出,外科医生应意识到用于前交叉韧带重建的跟腱同种异体移植物力学属性存在相当大的变异。
  • 作者指出,这种变异难以通过组织库筛查或治疗外科医生的检查发现,并可能 contribute 于同种异体移植物前交叉韧带重建结局的异质性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Allograft tendon used in anterior cruciate ligament reconstruction (ACLR) requires sterilization before implantation. Low-dose gamma irradiation is a means of sterilization that may minimize tissue damage. PURPOSE: To quantify the variability in mechanical properties between low-dose irradiated Achilles tendon allografts used for ACLR. STUDY DESIGN: Descriptive laboratory study. METHODS: A total of 15 intact outer-third Achilles tendon allograft specimens were collected from the remains of full Achilles allografts used for intraoperative ACLR at a single hospital. All grafts were obtained from a single tissue bank and underwent proprietary disinfection and low-dose gamma irradiation (1.5-2.5 Mrad). Biomechanical testing was carried out to measure tendon elongation, failure location during tensile testing, maximum stress, maximum strain, and modulus of elasticity. The mean and standard deviation were calculated for each outcome measure, and the variability between specimens was calculated by the coefficient of variation (CV). The effect of donor age on graft material properties was examined by use of linear regression. One-way analysis of variance was performed to compare differences in the mechanical properties across failure locations. RESULTS: During cyclic testing, tendon elongation averaged 1.4% ± 1.6% with a CV of 118%. During failure testing, the maximum stress averaged 12.2 ± 4.1 MPa, maximum strain averaged 21.0% ± 6.3%, and modulus of elasticity averaged 95.5 ± 30.8 MPa. The CVs for maximum stress, maximum strain, and modulus of elasticity were 34%, 30%, and 32%, respectively. Ten tendons failed in the midsubstance and 5 failed at the tendon-bone enthesis. No differences were noted in mechanical properties between grafts that failed in the midsubstance versus those that failed at the enthesis. Donor age did not correlate with allograft elongation during cyclic load or any of the material property measures during failure testing. CONCLUSION: The variabilities in the material properties and graft elongation during cyclic loading of Achilles tendon allografts used in ACLR fall within the range of properties reported in the literature for other ACLR allografts. Material properties do not differ by donor age or graft failure location observed during failure testing. CLINICAL RELEVANCE: Surgeons should be aware that there exists considerable variation in the mechanical properties of Achilles allograft tendons used for ACLR. This variability is difficult to detect by tissue bank screening or the treating surgeon's inspection and may contribute to the heterogeneity in outcomes of allograft ACLR.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Weber AE, Mayer EN, Nathani A, et al. How Variable Are Achilles Allografts Used for Anterior Cruciate Ligament Reconstruction? A Biomechanical Study. Am J Sports Med. 2018. PMID: 29741921. doi:10.1177/0363546518768780

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。