文献速递运动医学关节外科

前交叉韧带胫骨足迹磁共振成像测量能否可靠预测实际大小

Anterior Cruciate Ligament Tibial Footprint Size as Measured on Magnetic Resonance Imaging: Does It Reliably Predict Actual Size?
PubMed 文献 · Am J Sports Med · 2018-05-08

本研究纳入164例平均年龄67.3岁的患者,在全膝关节置换术中实际测量前交叉韧带胫骨足迹,并与MRI测量值比较。MRI测量长度和宽度与实际值强相关(ρ=0.904和ρ=0.808),但存在差异(长度12.4 mm vs 13.8 mm,宽度8.8 mm vs 7.2 mm,P<.001)。基于MRI测量和性别建立的预测方程显示良好的一致性相关系数(R²=0.83和R²=0.75)。

要点

  • MRI测量前交叉韧带胫骨足迹长度和宽度与实际值强相关(ρ=0.904和ρ=0.808)。
  • MRI测量与实际测量存在差异:长度12.4 mm vs 13.8 mm,宽度8.8 mm vs 7.2 mm(P<.001)。
  • 基于MRI测量和性别的预测方程可提高预测实际大小的准确性(R²=0.83和R²=0.75)。

核心结论

  • MRI测量前交叉韧带胫骨足迹大小与实际大小强相关,预测方程显示良好的一致性相关系数。

研究设计与样本

  • 队列研究(诊断性),证据等级2,纳入164例评估正常且MRI可视前交叉韧带的患者,平均年龄67.3±8.3岁,在全膝关节置换术中解剖并测量前交叉韧带胫骨足迹。

主要发现

  • MRI测量长度与实际长度强相关(ρ=0.904),MRI测量宽度与实际宽度强相关(ρ=0.808)。
  • MRI测量长度12.4 mm(范围9.7-15.3 mm) vs 实际长度13.8 mm(范围10.6-17.8 mm),P<.001。
  • MRI测量宽度8.8 mm(范围7.0-12.1 mm) vs 实际宽度7.2 mm(范围5.8-10.4 mm),P<.001。
  • 男性MRI长度12.6 mm(范围10.9-15.3 mm) vs 实际14.2 mm(范围12.3-17.8 mm);女性MRI长度12.4 mm(范围9.7-14.5 mm) vs 实际13.7 mm(范围10.6-15.8 mm);男性MRI宽度9.3 mm(范围8.0-12.1 mm) vs 实际7.6 mm(范围5.8-10.4 mm);女性MRI宽度8.7 mm(范围7.0-10.4 mm) vs 实际7.2 mm(范围5.8-9.7 mm),P<.001。
  • 实际长度可由MRI长度和性别预测(R²=0.83,P<.001);实际宽度可由MRI宽度和性别预测(R²=0.75,P<.001)。

临床怎么用

  • 作者认为基于MRI测量和性别的预测方程可提高预测前交叉韧带胫骨足迹实际大小的准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Measuring the size of the anterior cruciate ligament (ACL) tibial footprint on magnetic resonance image (MRI) is common for preoperative planning of ACL reconstruction. However, the accuracy of such measurement has not been well documented. PURPOSE: To investigate whether the actual size of the ACL tibial footprint could be predicted by its measurement on MRI and to develop equations to improve the accuracy of predicting the actual size based on MRI measurement. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: A total of 164 patients with normal visualized ACL in gross evaluation and MRI were included (mean ± SD age, 67.3 ± 8.3 years). Cases with ACL tear, severe mucoid degeneration, osteophyte around the ACL tibial insertion, or intervals >12 months between MRI and actual measurement were excluded. The ACL tibial footprint was carefully dissected and measured during total knee arthroplasty. The length of the ACL tibial footprint on MRI was measured on a sagittal image, while the width was measured on an oblique coronal image. For the ACL tibial footprint, the association between measurement on MRI and actual measurement of length and width was analyzed via univariable and multivariable regression analyses. Reliability of measurements on MRI was also evaluated. RESULTS: The length and width of the ACL tibial footprint as measured on MRI showed strong correlation with the actual length and width (coefficients: ρ = 0.904 and ρ = 0.808, respectively). There were differences between ACL size on MRI and its actual size: length, 12.4 mm (range, 9.7-15.3 mm) vs 13.8 (10.6-17.8) ( P < .001); width, 8.8 mm (range, 7.0-12.1 mm) vs 7.2 (5.8-10.4) ( P < .001). Based on sex, there were also differences between the size per MRI and the actual size ( P < .001 for all): length in men, 12.6 mm (range, 10.9-15.3 mm) vs 14.2 (12.3-17.8); length in women, 12.4 mm (range, 9.7-14.5 mm) vs 13.7 (10.6-15.8); width in men, 9.3 mm (range, 8.0-12.1 mm) vs 7.6 (5.8-10.4); width in women, 8.7 mm (range, 7.0-10.4 mm) vs 7.2 (5.8-9.7). The actual length of the ACL tibial footprint could be predicted by its length on MRI and sex ( R2 = 0.83, P < .001). Similarly, actual width could be predicted by the width on MRI and sex ( R2 = 0.75, P < .001). All intraclass correlation coefficients were >0.8, indicating good reliability. CONCLUSION: Measurements of the size of the ACL tibial footprint on MRI showed strong correlation with its actual size. Prediction equations showed good concordance correlation coefficients.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Kim SH, Lee HJ, Park YB, et al. Anterior Cruciate Ligament Tibial Footprint Size as Measured on Magnetic Resonance Imaging: Does It Reliably Predict Actual Size? Am J Sports Med. 2018. PMID: 29738676. doi:10.1177/0363546518767874

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。