文献速递关节外科创伤骨科

模块化双动关节界面在翻修髋臼重建中应用的早期报告

An Early Report of the Use of a Modular Dual Mobility Articulation in Revision Acetabular Reconstruction.
PubMed 文献 · J Arthroplasty · 2018-05-09

本研究纳入60例连续接受翻修髋关节手术并置入模块化双动髋臼杯(Stryker)的患者,随访至少24个月,评估临床、影像学和患者报告结局,并检测部分患者血清钴铬离子水平。结果显示总体功能与疼痛缓解良好,平均满意度78分,以翻修为终点的生存率为90%,中位血清铬0.4 µg/L、钴0.42 µg/L。作者认为模块化双动髋臼杯是翻修髋关节手术中高不稳风险患者的优良选择。

要点

  • 60例翻修髋关节手术患者置入模块化双动髋臼杯,随访至少24个月,功能与疼痛缓解良好。
  • 以翻修为终点的生存率为90%,3例因持续不稳翻修,3例因感染翻修。
  • 中位血清铬0.4 µg/L(范围0.1-6.1 µg/L),钴0.42 µg/L(范围0.21-9.42 µg/L)。

核心结论

  • 作者认为,模块化双动髋臼杯是翻修髋关节手术中高不稳风险患者的优良选择,本系列患者报告结局良好且并发症与翻修率低。

研究设计与样本

  • 本研究为早期报告,纳入60例连续接受翻修髋关节手术并置入模块化双动髋臼杯(Stryker,Mahwah,NJ)的患者,随访至少24个月。

主要发现

  • 末次随访时5例死亡,3例因持续不稳接受翻修,3例因感染接受翻修。
  • 总体功能结局:平均WOMAC功能评分76,UCLA评分5.6,平均Oxford评分74.7,SF-12躯体评分41.6、心理评分53.3。
  • 总体疼痛缓解:平均WOMAC疼痛评分78.3;平均满意度评分78分(满分100)。
  • 末次随访中位血清铬0.4 µg/L(范围0.1-6.1 µg/L),中位血清钴0.42 µg/L(范围0.21-9.42 µg/L)。
  • 以翻修为终点的生存率为90%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Instability remains one of the main problems after revision hip surgery. The aim of this study was to review the clinical, radiological, and patient-reported outcomes with the use of modular dual-mobility articulation for revision acetabular reconstruction and investigate the risk of fretting corrosion by measuring serum trace metal ion levels. METHODS: Sixty consecutive patients with a minimum of 24-month follow-up after the insertion of a modular dual-mobility (Stryker, Mahwah, NJ) cup at the time of revision hip surgery were identified. Follow-up included clinical and radiological patient review and functional outcome measures, and a subset of patients had their metal ion (cobalt and chromium) levels checked. RESULTS: At the most recent follow-up, 5 patients had died, 3 patients have been revised because of ongoing instability, and 3 patients have had revision surgery due to infection. Overall functional outcome (mean Western Ontario and McMaster Universities Osteoarthritis Indexfunction 76, University of California, Los Angeles 5.6, mean Oxford 74.7, Short Form-12 physical 41.6/mental 53.3) and overall pain relief (mean Western Ontario and McMaster Universities Osteoarthritis Index pain score 78.3) scores were good. The mean satisfaction score was 78 of 100. The median serum trace metal chromium and cobalt levels at the most recent follow-up were 0.4 µg/L (range 0.1-6.1 µg/L) and 0.42 µg/L (range 0.21-9.42 µg/L), respectively. The survival with revision as the end point was 90%. CONCLUSIONS: Dual-mobility cups with modularity represent an excellent option for the patient having revision hip surgery at high risk of instability. This series presents good patient-reported outcome measures and a low complication and revision rate.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Diamond OJ, Konan S, Greidanus NV, et al. An Early Report of the Use of a Modular Dual Mobility Articulation in Revision Acetabular Reconstruction. J Arthroplasty. 2018. PMID: 29807791. doi:10.1016/j.arth.2018.05.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。