文献速递关节外科

钴/铬比值与低钴阈值在预测金属对金属髋关节置换患者不良局部组织反应中具有相似的诊断价值

The Cobalt/Chromium Ratio Provides Similar Diagnostic Value to a Low Cobalt Threshold in Predicting Adverse Local Tissue Reactions in Patients With Metal-on-Metal Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-04-09

该研究纳入310例单侧金属对金属髋关节置换患者,均行金属伪影减少序列磁共振成像检测不良局部组织反应(ALTR)并测量血钴、铬水平。金属对金属全髋关节置换患者的钴/铬比值高于金属对金属髋关节表面置换患者(1.7 vs 0.9,P < .001)。钴/铬比值与血钴水平对ALTR具有相似预测价值,最敏感的钴/铬比值临界值为1.4(灵敏度80.0%,特异度48.7%),血钴临界值为2.4 ppb(灵敏度77.8%,特异度46.2%)。

要点

  • 金属对金属全髋关节置换患者的钴/铬比值高于表面置换患者(1.7 vs 0.9,P < .001)。
  • 连续钴/铬比值、连续血钴及血钴≥7 ppb均可预测ALTR。
  • 最敏感的ALTR临界值:钴/铬比值1.4(灵敏度80.0%,特异度48.7%),血钴2.4 ppb(灵敏度77.8%,特异度46.2%)。

核心结论

  • 血金属离子是金属对金属髋关节置换患者ALTR的强预测因素,但并不完美。
  • 较高的钴/铬比值与金属对金属全髋关节置换患者ALTR风险增加相关。
  • 单独血钴水平预测ALTR的能力与钴/铬比值相当。
  • 最敏感的ALTR临界值低于既往文献报道。

研究设计与样本

  • 研究纳入310例单侧金属对金属髋关节置换患者,包括髋关节表面置换和全髋关节置换。
  • 所有患者接受金属伪影减少序列磁共振成像检测ALTR,并测量血钴和铬水平。

主要发现

  • 金属对金属全髋关节置换患者的钴/铬比值高于金属对金属髋关节表面置换患者(1.7,四分位距1.2-3.1 vs 0.9,四分位距0.7-1.3,P < .001)。
  • 连续钴/铬比值、连续血钴及血钴≥7 ppb在受试者工作特征分析中可预测ALTR。
  • 最敏感且特异的临界值:钴/铬比值1.4(灵敏度80.0%,特异度48.7%),血钴2.4 ppb(灵敏度77.8%,特异度46.2%)。
  • 多变量分析中,连续血钴、血钴≥7 ppb及受试者工作特征分析生成的临界值与ALTR患病率相关。

关键数值与推荐

  • 钴/铬比值临界值1.4:灵敏度80.0%,特异度48.7%。
  • 血钴临界值2.4 ppb:灵敏度77.8%,特异度46.2%。
  • 血钴≥7 ppb可预测ALTR。
  • 金属对金属全髋关节置换患者钴/铬比值中位数1.7(四分位距1.2-3.1),表面置换患者0.9(四分位距0.7-1.3),P < .001。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A higher cobalt/chromium (Co/Cr) ratio is thought to be associated with corrosion of the trunnion and increased adverse local tissue reaction (ALTR) risk in patients treated with metal-on-metal (MoM) hip arthroplasty. The main aim of this study was to investigate the diagnostic value of Co/Cr ratio in identifying ALTR in patients treated with MoM hip resurfacing arthroplasty and total hip arthroplasty (THA). METHODS: A total of 310 unilateral patients were included. All patients received a metal artifact reduction sequence magnetic resonance imaging to detect ALTR. Blood Co and Cr levels were measured. RESULTS: MoM THA patients had a higher Co/Cr ratio than MoM hip resurfacing arthroplasty patients (1.7, interquartile range 1.2-3.1 vs 0.9, interquartile range 0.7-1.3, P < .001). The continuous Co/Cr ratio, continuous Co, and Co ≥ 7 ppb were predictive of ALTR when tested in receiver-operating characteristic analyses. The most sensitive and specific cutoffs were found to be 1.4 for Co/Cr ratio (sensitivity = 80.0%; specificity = 48.7%) and 2.4 ppb for Co (sensitivity = 77.8%; specificity = 46.2%). In multivariate analysis, continuous Co, Co ≥ 7 ppb, and the receiver-operating characteristic analysis-generated cutoffs were associated with ALTR prevalence. CONCLUSION: Blood metal ions are strong, but not perfect, predictors of ALTR in patients with MoM hip arthroplasty. Higher Co/Cr ratios are associated with increased risk for ALTR in MoM THA. However, blood Co levels alone are as good a predictor of ALTR as the Co/Cr ratio. The most ALTR-sensitive cutoffs are lower than previously reported in the literature.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Laaksonen I, Galea VP, Donahue GS, et al. The Cobalt/Chromium Ratio Provides Similar Diagnostic Value to a Low Cobalt Threshold in Predicting Adverse Local Tissue Reactions in Patients With Metal-on-Metal Hip Arthroplasty. J Arthroplasty. 2018. PMID: 29716769. doi:10.1016/j.arth.2018.03.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。