文献速递关节外科

在适当选择的患者中,增加约束度的孤立聚乙烯衬垫更换与组件翻修全膝关节置换术治疗不稳定性相当

Isolated Polyethylene Exchange With Increased Constraint Is Comparable to Component Revision TKA for Instability in Properly Selected Patients.
PubMed 文献 · J Arthroplasty · 2018-05-03

该回顾性研究纳入90例因全膝关节置换术后不稳定性行翻修术的患者,平均随访3.7年。40%符合标准化术前和术中标准的患者接受孤立胫骨聚乙烯衬垫更换(ITPIE)并增加约束度,60%不符合标准者接受一个或两个组件翻修。两组Knee Society评分改善、活动度和失败率无显著差异,但ITPIE组再翻修率显著更低(6.3% vs 30.8%)。作者认为在选定患者中ITPIE不劣于组件翻修,翻修时应尽可能增加约束度。

要点

  • 在符合标准化标准的患者中,增加约束度的孤立聚乙烯衬垫更换与组件翻修的Knee Society评分改善和失败率无显著差异。
  • ITPIE组再翻修率显著低于组件翻修组(6.3% vs 30.8%,OR 0.15,P = .004)。
  • 作者认为翻修治疗不稳定性时应尽可能增加聚乙烯衬垫的约束度。

核心结论

  • 在选定患者中,孤立胫骨聚乙烯衬垫更换(ITPIE)治疗全膝关节置换术后症状性不稳定性不劣于组件翻修。
  • 作者认为翻修手术治疗不稳定性时应尽可能增加约束度。

研究设计与样本

  • 回顾性综述了单中心连续90例因不稳定性行翻修性全膝关节置换术的患者,至少随访2年(平均3.7年)。
  • 平均年龄62.0岁(范围41至83岁),73%为女性。
  • 40%的患者在符合标准化术前和术中标准时接受ITPIE,60%在不符合标准时接受一个或两个组件翻修。

主要发现

  • 患者Knee Society膝关节评分从48.4改善至82.6(P < .001),功能评分从49.0改善至81.0(P < .001)。
  • ITPIE组与组件翻修组在Knee Society膝关节评分改善(38.1 vs 33.1;P = .18)、功能评分改善(36.0 vs 34.0;P = .63)和活动度(5° vs 6°;P = .88)方面无显著差异。
  • 失败率在ITPIE组为19.4%,在组件翻修组为18.5%(比值比1.06;P = .91)。
  • 增加聚乙烯衬垫约束度时再翻修率显著更低(6.3% vs 30.8%;比值比0.15;P = .004)。

临床怎么用

  • 作者认为在选定患者中,ITPIE处理全膝关节置换术后症状性不稳定性不劣于组件翻修。
  • 作者建议翻修手术治疗不稳定性时应尽可能增加约束度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Symptomatic instability following total knee arthroplasty (TKA) is a leading cause of early failure. Most reports recommend component revision as the preferred treatment because of poor outcomes and high failure rates with isolated tibial polyethylene insert exchange (ITPIE). However, these ideas have not been tested in modern implant systems that allow insert constraint to be increased. METHODS: We retrospectively reviewed 90 consecutive patients with minimum 2-year (mean 3.7 years) follow-up who underwent revision TKA for instability at a single institution. Mean age was 62.0 years (range, 41 to 83 years), and 73% of patients were women. Forty percent of patients were treated with ITPIE when standardized preoperative and intraoperative criteria were met; 60% underwent revision of one or both components when these criteria were not met. RESULTS: Patients experienced significant improvements in Knee Society (KS) knee (48.4 to 82.6; P < .001) and function (49.0 to 81.0; P < .001) scores. There were no significant differences in improvements in KS knee scores (38.1 vs 33.1; P = .18), KS function scores (36.0 vs 34.0; P = .63), or arc of motion (5° vs 6°; P = .88) between those treated with ITPIE and component revision. Failure rates were 19.4% in the ITPIE group vs 18.5% in the component revision group (odds ratio, 1.06; P = .91). Re-revision rates were significantly lower (6.3% vs 30.8%; odds ratio, 0.15; P = .004) when polyethylene insert constraint was increased. CONCLUSION: In selected patients, ITPIE is not inferior to component revision at addressing symptomatic instability following TKA. Degree of constraint should be increased whenever possible during revision surgery for instability.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Cooper HJ, Moya-Angeler J, Bas-Aguilar MA, et al. Isolated Polyethylene Exchange With Increased Constraint Is Comparable to Component Revision TKA for Instability in Properly Selected Patients. J Arthroplasty. 2018. PMID: 29805104. doi:10.1016/j.arth.2018.04.042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。