文献速递关节外科

体力活动与金属对金属全髋关节置换及表面置换髋关节置换患者的铬离子水平相关,但与假瘤大小变化无关

Physical Activity Is Associated With the Level of Chromium but Not With Changes in Pseudotumor Size in Patients With Metal-on-Metal Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-04-30

前瞻性队列研究纳入111例患者共148个髋关节(77个金属对金属全髋/表面置换髋关节,71个金属对聚乙烯全髋关节),在1年随访期内进行5次横断面分析,监测每日体力活动、铬和钴离子水平及假瘤大小。结果发现金属对金属髋关节患者每日体力活动与铬离子水平在所有随访点均呈统计学显著相关(P≤.03),但与假瘤大小变化无关(P>.30)。

要点

  • 金属对金属全髋/表面置换髋关节患者每日体力活动与铬离子水平在所有随访点均呈统计学显著相关(P≤.03)。
  • 金属对聚乙烯全髋关节患者每日体力活动与铬离子水平无统计学显著相关(P>.35)。
  • 每日体力活动与假瘤大小变化在所有随访点均无统计学显著相关(P>.30);金属对金属组26个假瘤中10个(38%)、金属对聚乙烯组29个中8个(28%)按Anderson分级发生分类变化,无假瘤外观转变或解剖位置改变。

核心结论

  • 金属对金属全髋/表面置换髋关节患者的每日体力活动与铬离子水平相关,但与假瘤大小变化无关。
  • 作者认为这一新知识可能有助于髋关节外科医生对活跃的金属对金属全髋/表面置换髋关节患者进行体力活动后果的推荐和监测。

研究设计与样本

  • 前瞻性队列研究,纳入111例患者共148个髋关节,其中金属对金属全髋/表面置换髋关节77个、金属对聚乙烯全髋关节71个。
  • 在1年随访期内进行5次横断面分析;基线随访时间为术后平均7.1年(范围0.2-21.5年)。
  • 基线和之后每3个月,在2周期间使用三轴加速度计监测每日体力活动,并完成金属伪影减少序列磁共振成像、铬和钴离子测量及哥本哈根髋和腹股沟结局评分问卷。

主要发现

  • 金属对金属全髋/表面置换髋关节患者每日体力活动与铬离子水平在所有随访点均呈统计学显著相关(P≤.03)。
  • 金属对聚乙烯全髋关节患者每日体力活动与铬离子水平无统计学显著相关(P>.35)。
  • 每日体力活动与假瘤大小变化在所有随访点均无统计学显著相关(P>.30)。
  • 金属对金属全髋/表面置换髋关节组26个假瘤中10个(38%)按Anderson分级发生分类变化,金属对聚乙烯全髋关节组29个假瘤中8个(28%)发生分类变化。
  • 无假瘤外观转变或解剖位置改变。

临床怎么用

  • 作者认为每日体力活动与铬离子水平相关而与假瘤大小变化无关这一新知识,可能有助于髋关节外科医生对活跃的金属对金属全髋/表面置换髋关节患者进行体力活动后果的推荐和监测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA) were previously considered an excellent option for young and physically active patients. However, the relationship between MoM THA/RHA patients' daily physical activity (PA), metal ion measurements of chromium and cobalt, and pseudotumor dynamic is insufficiently explored. METHODS: One hundred eleven patients with 148 hip articulations, 77 MoM THA/RHA and 71 MoP THA, participated in a prospective cohort study, with 5 cross-sectional analyses during a 1-year follow-up. Baseline follow-up was at mean 7.1 (range: 0.2-21.5) years postoperative. At baseline and every 3 months thereafter, patients' daily PA was monitored during a 2-week period using a triaxial accelerometer, and next metal artifact reducing sequence magnetic resonance imaging scans, metal ion measurements of chromium and cobalt, and the Copenhagen Hip and Groin Outcome Score questionnaire were completed. RESULTS: We found a statistically significant relationship between daily PA and metal ion measurements of chromium at all follow-ups in MoM THA/RHA patients (P ≤ .03) but not in MoP THA patients (P > .35). Patients' daily PA was not related to changes in pseudotumor size at any follow-up (P > .30). Ten of 26 (38%) pseudotumors in MoM THA/RHA and 8 of 29 (28%) pseudotumors in MoP THA changed classification according to the Anderson grading. No pseudotumors transformed in appearance or changed anatomical location. CONCLUSION: The daily PA of MoM THA/RHA patients is associated with metal ion measurements of chromium but not with changes in pseudotumor size. This is new and important knowledge, which may be useful for hip surgeons in recommendation and monitoration of the consequences of PA in active patients with MoM THA/RHA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hjorth MH, Mechlenburg I, Soballe K, et al. Physical Activity Is Associated With the Level of Chromium but Not With Changes in Pseudotumor Size in Patients With Metal-on-Metal Hip Arthroplasty. J Arthroplasty. 2018. PMID: 29807790. doi:10.1016/j.arth.2018.04.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。