文献速递关节外科

固定平台内侧骨水泥型单髁膝关节置换术的疗效:460例生存分析与功能评分

Outcomes of a Fixed-Bearing, Medial, Cemented Unicondylar Knee Arthroplasty Design: Survival Analysis and Functional Score of 460 Cases.
PubMed 文献 · J Arthroplasty · 2018-04-24

这项回顾性研究纳入2005至2013年单中心连续460例接受固定平台内侧单髁膝关节置换术的患者,平均随访5.5年,Oxford膝关节评分平均43.3分,94.6%患者获优或良,翻修11例(2.4%),5年和10年生存率分别为97.2%和94.2%。作者认为固定平台单髁膝关节置换术是内侧终末期骨关节炎的良好治疗选择。

要点

  • 平均随访5.5年,Oxford膝关节评分平均43.3分,94.6%患者为优或良。
  • 翻修11例(2.4%),5年生存率97.2%(95%CI 96.2%-99.2%),10年94.2%(95%CI 86.8%-97.5%)。
  • 翻修原因包括感染4例(0.9%)、外侧间室过载疼痛2例(0.4%)等,无因松动、不稳、磨损或假体周围骨折翻修。

核心结论

  • 作者认为固定平台单髁膝关节置换术系统是内侧终末期骨关节炎的良好治疗选择,功能结果满意且并发症和翻修发生率低。

研究设计与样本

  • 回顾性研究,2005至2013年在一家中心连续纳入460例接受固定平台内侧单髁膝关节置换术的患者。
  • 术前及术后6周和1年进行临床和影像学评估,2016年2月至4月使用Oxford膝关节评分复评。

主要发现

  • 平均随访5.5年(范围2-11年),Oxford膝关节评分平均43.3分(范围7-48),94.6%患者为优或良。
  • 翻修11例(2.4%),以任何原因任何假体部件翻修为终点,5年生存率97.2%(95%CI 96.2%-99.2%),10年生存率94.2%(95%CI 86.8%-97.5%)。
  • 翻修原因:感染4例(0.9%)、外侧间室过载致外侧疼痛2例(0.4%)、外侧间室骨关节炎进展2例(0.4%)、髌骨疼痛伴髌骨软骨病2例(0.4%)、严重滑膜炎1例(0.2%)。
  • 无因假体部件松动、不稳、假体磨损或假体周围骨折而再次手术或翻修。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Unicompartmental knee arthroplasty (UKA) is an alternative to total knee arthroplasty in isolated medial osteoarthritis (OA). However, despite satisfactory reports on the clinical performance, UKA revision rates are still concerning. This retrospective study reports on the long-term survivorship, functional outcomes, and reasons for revision in fixed-bearing UKA implant. METHODS: Between 2005 and 2013, 460 consecutive patients were treated with medial UKA in one center using a fixed-bearing UKA system. All patients were evaluated clinically and radiographically before surgery, and postoperatively at 6 weeks and 1 year. Between February and April 2016, all patients were reevaluated using the Oxford Knee Score. RESULTS: Mean follow-up was 5.5 (range, 2-11) years. The mean Oxford Knee Score was 43.3 (7-48), with 94.6% patients showing excellent or good outcomes. Eleven revisions (2.4%) occurred. The survivorship was 97.2% (95% confidence interval, 96.2%-99.2%) and 94.2% (95% confidence interval, 86.8%-97.5%) at 5 and 10 years, respectively, with revision of any implant component for any reason as the end point. The causes for revision were infection (4 cases, 0.9%); lateral pain due to overload (2 cases, 0.4%); progression of OA in the lateral compartment (2 cases, 0.4%); patellar pain with patellar chondropathy (2 cases, 0.4%); and severe synovitis (1 cases, 0.2%). There were no reoperations or revisions for component loosening, instability, component wear, or periprosthetic fracture. CONCLUSION: A fixed-bearing UKA system is a good treatment option for medial end-stage OA. Satisfactory functional results were achieved with low incidence of complications and revisions.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Winnock de Grave P, Barbier J, Luyckx T, et al. Outcomes of a Fixed-Bearing, Medial, Cemented Unicondylar Knee Arthroplasty Design: Survival Analysis and Functional Score of 460 Cases. J Arthroplasty. 2018. PMID: 29776853. doi:10.1016/j.arth.2018.04.031