文献速递关节外科

离心可能改变白细胞酯酶试纸法诊断假体周围关节感染的结果

Centrifugation May Change the Results of Leukocyte Esterase Strip Testing in the Diagnosis of Periprosthetic Joint Infection.
PubMed 文献 · J Arthroplasty · 2018-04-19

研究纳入2016年4月至2017年10月的133例患者(53例感染、80例非感染),对比离心前后白细胞酯酶试纸结果。离心后几乎所有样本颜色变浅,感染组18.6%(8/43)和非感染组17.9%(12/67)的病例结果降级。作者建议未离心时以++为阳性阈值,离心后阈值应降至++和+。

要点

  • 离心后几乎所有滑液样本白细胞酯酶试纸颜色变浅,部分病例结果降级。
  • 未离心时以++为阳性阈值,敏感度97.7%、特异度100%。
  • 离心后以++和+为阳性阈值,敏感度92.5%、特异度100%。

核心结论

  • 解读白细胞酯酶试纸结果时应考虑离心的影响。
  • 作者建议未离心病例以++为阳性阈值,离心病例阈值应降至++和+。

研究设计与样本

  • 2016年4月至2017年10月纳入133例患者,其中感染53例、非感染80例。
  • 110例在离心前后各取一滴滑液进行白细胞酯酶试纸检测,另23例因血液污染颜色干扰无法在未离心时判读。
  • 约3分钟后按比色卡记录不同颜色等级,包括3级(++)、2级(+)和1级(其他)。

主要发现

  • 离心后几乎所有样本颜色较离心前变浅。
  • 感染组18.6%(8/43)和非感染组17.9%(12/67)的病例结果降级。
  • 未离心时以3级(++)为阳性阈值,敏感度97.7%(86.2%-99.9%),特异度100%(94.3%-100%)。
  • 离心后以2级和3级(+和++)为阳性阈值,敏感度92.5%(80.9%-97.6%),特异度100%(94.3%-100%)。

关键数值与推荐

  • 未离心时以3级(++)为阳性阈值,敏感度97.7%(86.2%-99.9%),特异度100%(94.3%-100%)。
  • 离心后以2级和3级(+和++)为阳性阈值,敏感度92.5%(80.9%-97.6%),特异度100%(94.3%-100%)。

临床怎么用

  • 作者建议未离心病例以++为阳性阈值,离心病例阈值应降至++和+。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Centrifugation is used to remove the color interference by erythrocytes in blood-synovial fluid samples before leukocyte esterase (LE) strip testing. However, the impact of centrifugation requires further study. METHODS: From April 2016 to October 2017, 133 (53 infected and 80 noninfected) patients were included in this study. One drop of synovial fluid was applied to LE strips before and after centrifugation in 110 cases. The other 23 cases could not be read without centrifugation due to the color disturbance caused by blood contamination. The results were recorded after approximately 3 minutes according to different color grades on a color chart, including grade 3 (++), grade 2 (+), and grade 1 (others). RESULTS: After centrifugation, almost every sample was lighter in color than before. Although most results changed inconspicuously and remained in the same grade, 18.6% (8/43) and 17.9% (12/67) of cases were downgraded in the periprosthetic joint infection and non-periprosthetic joint infection groups, respectively. Before centrifugation, when grade 3 (++) was used as the positive threshold, the sensitivity and specificity were 97.7% (86.2%-99.9%) and 100% (94.3%-100%), respectively. After centrifugation, when grades 2 and 3 (+ and ++, respectively) were used as the positive threshold, the sensitivity and specificity were 92.5% (80.9%-97.6%) and 100% (94.3%-100%), respectively. CONCLUSIONS: The influence of centrifugation should be considered when interpreting the LE strip test results. For cases without centrifugation, we recommended using ++ as the positive threshold, while for cases using centrifugation, the threshold should be reduced to both ++ and +.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Li R, Lu Q, Zhou YG, et al. Centrifugation May Change the Results of Leukocyte Esterase Strip Testing in the Diagnosis of Periprosthetic Joint Infection. J Arthroplasty. 2018. PMID: 29752029. doi:10.1016/j.arth.2018.04.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。