运动学对线与机械对线全膝关节置换术中股骨前髁截骨的形态学模式
研究将60例全膝关节置换候选者的CT重建为3D模型,用3°、5°、7°前翼屈曲角虚拟截骨,比较机械对线与运动学对线及内外旋3°时的AC/BC比值。标准机械对线各角度比值为0.57、0.60、0.63,标准运动学对线为0.73、0.74、0.76;旋转不良平面的比值与两者均有显著差异(P<.01)。作者认为术者可辅助使用该量化方法确保股骨截骨旋转对线。
要点
- 前翼屈曲角3°、5°、7°时,标准机械对线AC/BC比值为0.57、0.60、0.63。
- 相同角度下标准运动学对线AC/BC比值为0.73、0.74、0.76。
- 旋转不良平面的AC/BC比值与标准机械及运动学对线均显著不同(P<.01)。
核心结论
- 术者可辅助使用该量化方法在术中确保机械对线和运动学对线全膝关节置换术中股骨截骨的旋转对线正确。
研究设计与样本
- 研究为影像学虚拟截骨研究,将60例全膝关节置换候选者的CT扫描重建为3D模型。
- 用3D成像程序以3°、5°、7°前翼屈曲角虚拟截骨,机械对线组截骨平行于外科上髁轴并相对其外旋和内旋3°,运动学对线组截骨平行于圆柱轴并相对其外旋和内旋3°。
- AC/BC比值定义为股骨远端截骨前缘至股骨前髁截骨内外侧髁最近端峰点的垂直距离之比。
主要发现
- 标准机械对线法前翼屈曲角3°、5°、7°时,AC/BC比值分别为0.57、0.60、0.63。
- 标准运动学对线法前翼屈曲角3°、5°、7°时,AC/BC比值分别为0.73、0.74、0.76。
- 旋转不良平面的AC/BC比值与标准机械对线和标准运动学对线均显著不同(P值<.01)。
临床怎么用
- 作者认为术者可辅助使用该量化方法在术中确保机械对线和运动学对线全膝关节置换术中股骨截骨的旋转对线正确。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: "Grand-piano sign" has been used as a popular benchmark to facilitate correct rotational alignment during total knee arthroplasty (TKA). The purpose was to quantitatively determine morphological patterns on anterior femoral resection in mechanically aligned (MA) and kinematically aligned (KA) TKA. METHODS: Computed tomography scans of 60 TKA candidates were reconstructed into 3D models. Femurs were virtually cut with a 3D imaging program using various anterior flange flexion angles (AFFAs) of 3°, 5°, and 7°. The anterior femoral resection was performed parallel to the surgical epicondylar axis, at an external rotation and internal rotation of 3° relative to surgical epicondylar axis for MA-TKA, and parallel to the cylindrical axis, at an external rotation and internal rotation of 3° to cylindrical axis for KA-TKA. The ratio of vertical distance from the anterior margin of distal femoral resection to the most proximal peak of each medial and lateral condyle of anterior femoral resection was defined as AC/BC ratio. RESULTS: The mean ratios of AC/BC were 0.57, 0.60, and 0.63 respectively, according to 3°, 5°, and 7° of AFFA with standard MA-TKA method and were 0.73, 0.74, and 0.76, respectively, according to 3°, 5°, and 7° of AFFA with standard KA-TKA method. The AC/BC ratios of malrotated planes were significantly different from those of both standard MA- and KA-TKAs (P-values < .01). CONCLUSION: Surgeons can accessorily use the quantifying method for anterior femoral resection intraoperatively to ensure correct rotational alignment of femoral resection in both mechanically and kinematically aligned TKA.
引用
- Kim JT, Han J, Shen QH, et al. Morphological Patterns of Anterior Femoral Condylar Resection in Kinematically and Mechanically Aligned Total Knee Arthroplasty. J Arthroplasty. 2018. PMID: 29739631. doi:10.1016/j.arth.2018.03.063
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。