「较厚」聚乙烯垫片与初次全膝关节置换术较高失败率无关
该回顾性研究分析2003至2014年单中心数据库6698例初次全膝关节置换术,按聚乙烯垫片厚度≤14 mm与>14 mm分为薄垫片组与厚垫片组,比较临床结局、翻修需求与假体生存率。厚垫片组术后膝关节协会临床与疼痛评分更优,两组再手术率及10年免翻修生存率相似,厚垫片组无因无菌性松动或不稳导致的失败。
要点
- 厚垫片组术前膝关节协会临床评分显著更低(P<.01),冠状面畸形更明显。
- 厚垫片组术后膝关节协会临床与疼痛评分更优,功能评分与加州大学洛杉矶分校活动评分相似。
- 两组再手术率与10年免翻修生存率相似,薄垫片组术后需麻醉下手法松解的可能性是厚垫片组的两倍(P=.02)。
核心结论
- 厚聚乙烯垫片组在多项临床结局与生存率方面表现与薄垫片组相似或更优。
研究设计与样本
- 回顾性研究,纳入2003至2014年单中心数据库的初次全膝关节置换术患者,按制造商聚乙烯垫片尺寸≤14 mm与>14 mm分为薄垫片组与厚垫片组,共6698例,其中96.5%使用薄垫片。
- 评估患者临床结局、翻修手术需求及总体假体生存率。
主要发现
- 术前厚垫片组膝关节协会临床评分显著更低(P<.01),功能评分有更低趋势(P=.06),冠状面畸形更明显。
- 术后厚垫片组膝关节协会临床与疼痛评分更优,功能评分与加州大学洛杉矶分校活动评分相似。
- 总体再手术率厚垫片组1.7% vs 薄垫片组2.3%,10年免翻修生存率厚垫片组98.2% vs 薄垫片组96.1%,两组相似。
- 薄垫片组术后需麻醉下手法松解的可能性是厚垫片组的两倍(P=.02)。
- 厚垫片组无因无菌性松动或不稳导致的失败。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Despite improvements in polyethylene bearing surface properties, only 1 previous study has examined the results of larger thickness bearings. The purpose of this study was to determine whether polyethylene thickness influenced patient outcomes and implant survival following modular total knee arthroplasty. METHODS: A retrospective review was performed of patients undergoing primary total knee arthroplasty from 2003 to 2014 in a single practice database. Patients were separated into "thin" and "thick" polyethylene groups based on manufacturer polyethylene bearing sizes of 14 mm or less compared to those greater than 14 mm, respectively. Patient clinical outcomes, need for revision surgery, and overall implant survival rates were evaluated. RESULTS: A total of 6698 primary knee arthroplasties were included, and a thin bearing was used in 96.5% of these cases. Preoperatively, patients with a thick bearing had significantly lower Knee Society clinical scores (P < .01), a trend toward lower functional scores (P = .06), and more significant coronal plane deformity. Postoperatively, patients with thick bearings exhibited better Knee Society clinical and pain scores as well as similar functional scores and University of California at Los Angeles activity scores. The overall reoperation rate and 10-year survivorship free of revision were similar between thick and thin bearings (1.7% vs 2.3%; 98.2% vs 96.1%). Patients with thin bearings were twice as likely to require a manipulation under anesthesia postoperatively (P = .02), while there were no failures in the thick bearing group due to aseptic loosening or instability. CONCLUSION: Patients with thick polyethylene bearings performed similarly or better in multiple clinical outcomes and survivorship compared to those with thin bearings.
引用
- Greco NJ, Crawford DA, Berend KR, et al. "Thicker" Polyethylene Bearings Are Not Associated With Higher Failure Rates in Primary Total Knee Arthroplasty. J Arthroplasty. 2018. PMID: 29773277. doi:10.1016/j.arth.2018.04.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。