文献速递脊柱外科小儿骨科

儿童脊柱侧凸透视引导下节段性椎弓根螺钉置入术中外科医生与患者的辐射暴露

Radiation Exposure to the Surgeons and Patients in Fluoroscopic-Guided Segmental Pedicle Screw Placement for Pediatric Scoliosis.
PubMed 文献 · Spine (Phila Pa 1976) · 2018-01-01

前瞻性病例系列研究,2016年3月至2017年12月纳入30例儿童脊柱侧凸患者,由两名外科医生(S1和S2)在透视引导下行节段性椎弓根螺钉置入。结果显示外科医生和患者辐射剂量均较低,但外科医生双手剂量远高于其他部位。作者认为可考虑使用防辐射手套并注意保护外科医生双手。

要点

  • 每例平均置入23.2±3.4枚椎弓根螺钉,外科医生和患者辐射暴露均较低。
  • 外科医生双手剂量远高于其他身体部位,S1右手16.87 mrem、左手6.07 mrem,S2右手13.73 mrem、左手11.37 mrem。
  • 作者认为可考虑使用防辐射手套并注意保护外科医生双手。

核心结论

  • 使用透视引导下节段性椎弓根螺钉技术行儿童脊柱侧凸手术,外科医生和患者辐射暴露均较低。
  • 外科医生双手接受的剂量远高于其他身体部位。
  • 作者认为可考虑使用防辐射手套并注意保护外科医生双手。

研究设计与样本

  • 前瞻性病例系列研究,2016年3月至2017年12月纳入30例儿童脊柱侧凸患者,由两名外科医生(S1和S2)在透视引导下行节段性椎弓根螺钉置入,测量外科医生和患者辐射剂量。

主要发现

  • 每例平均置入23.2±3.4枚椎弓根螺钉。
  • 外科医生S1每例平均剂量(mrem):额头0.07、甲状腺护罩外0.07、甲状腺护罩内0.00、右手16.87、左手6.07、背部0.50、铅围裙下耻骨上0.00。
  • 外科医生S2每例平均剂量(mrem):额头0.47、甲状腺护罩外0.37、甲状腺护罩内0.30、右手13.73、左手11.37、背部0.00、铅围裙下耻骨上0.00。
  • 男性患者每例甲状腺平均剂量3.67 mrem、性腺3.83 mrem;女性患者甲状腺14.71 mrem、性腺3.17 mrem。

临床怎么用

  • 作者认为可考虑使用防辐射手套并注意保护外科医生双手。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Prospective case series. OBJECTIVE: To analyze the radiation exposure to the surgeons and patients in fluoroscopic-guided segmental pedicle screw placement for pediatric scoliosis. SUMMARY OF BACKGROUND DATA: Fluoroscopic-guided pedicle screw placement is a safer technique for pedicle screw placement in spinal deformity. However, radiation exposure is a concern, particularly for spine surgeons due to the requirement of multiple pedicle screws in spinal deformity surgery. METHODS: We measured radiation dose to the surgeons and pediatric patients undergoing scoliosis surgery by a team of two surgeons (S1 and S2) from March 2016 to December 2017. Surgery was performed using fluoroscopic-guided segmental pedicle screw placement. The dosimeters were placed at the forehead, inside and outside thyroid shield, both hands, back, and suprapubic under lead apron for each surgeon; and at the thyroid and gonads for patients. RESULTS: Thirty patients were included in the study. The mean numbers of pedicle screws per case were 23.2 ± 3.4. The mean dose (mrem) per case for the two surgeons S1 and S2 was 0.07 and 0.47 at forehead, 0.07 and 0.37 at outside thyroid shield, 0.00 and 0.30 at inside thyroid shield, 16.87 and 13.73 at right hand, 6.07 and 11.37 at left hand, 0.50 and 0.00 at back, and 0.00 and 0.00 at suprapubic under lead apron, respectively. The mean dose (mrem) per case for the male and female patient was 3.67 and 14.71 for thyroid and 3.83 and 3.17 for gonads, respectively. CONCLUSION: The results of this study demonstrated that radiation exposure to the spine surgeons and patients is low using fluoroscopic-guided segmental pedicle screw technique for pediatric scoliosis surgery. Both hands of the surgeons received much higher doses compared to other body areas and, and thus radiation-reducing gloves and careful attention to surgeon's hands need to be considered for this procedure. LEVEL OF EVIDENCE: 2.