文献速递骨质疏松与代谢性骨病创伤骨科

脉冲电磁场通过促进骨合成代谢保护1型糖尿病兔骨架构与力学性能并刺激多孔植入物骨整合

Pulsed electromagnetic fields preserve bone architecture and mechanical properties and stimulate porous implant osseointegration by promoting bone anabolism in type 1 diabetic rabbits.
PubMed 文献 · Osteoporos Int · 2018-03-09

研究在四氧嘧啶诱导的1型糖尿病兔中观察脉冲电磁场(PEMF)对骨架构、力学性能及多孔钛(pTi)骨整合的影响。8周PEMF刺激减轻了松质骨与皮质骨架构及组织水平力学强度的恶化,促进pTi骨整合与骨长入,并减轻骨形成减少,但对骨吸收无影响。PEMF激活成骨细胞相关的Wnt/β-catenin信号,未改变破骨细胞相关的RANKL/RANK信号表达。

要点

  • 8周PEMF刺激减轻1型糖尿病兔松质骨与皮质骨架构及组织水平力学强度的恶化。
  • PEMF促进1型糖尿病长骨缺损中多孔钛的骨整合与骨长入。
  • PEMF减轻1型糖尿病相关的骨形成减少,对骨吸收无影响。

核心结论

  • PEMF通过经典Wnt/β-catenin信号相关机制促进骨合成代谢,改善骨架构、力学性能和多孔钛骨整合。
  • 研究为1型糖尿病相关骨量减少/骨质疏松和骨缺损提供了新的治疗选择思路。

研究设计与样本

  • 研究在四氧嘧啶诱导的1型糖尿病兔中评估PEMF刺激对骨架构、力学性能、骨转换及潜在分子机制的影响。
  • 研究开发了弹性模量更接近天然骨的无毒Ti2448多孔钛植入物,并观察PEMF对其骨整合的影响。

主要发现

  • 8周PEMF刺激减轻了松质骨和皮质骨架构及组织水平力学强度的恶化。
  • PEMF促进骨整合并刺激更多骨长入多孔钛孔隙。
  • PEMF显著减轻1型糖尿病相关的骨形成减少,但对骨吸收无影响。
  • PEMF激活1型糖尿病骨骼中成骨细胞相关的Wnt/β-catenin信号,未改变破骨细胞相关的RANKL/RANK信号基因表达。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: The effects of exogenous pulsed electromagnetic field (PEMF) stimulation on T1DM-associated osteopathy were investigated in alloxan-treated rabbits. We found that PEMF improved bone architecture, mechanical properties, and porous titanium (pTi) osseointegration by promoting bone anabolism through a canonical Wnt/β-catenin signaling-associated mechanism, and revealed the clinical potential of PEMF stimulation for the treatment of T1DM-associated bone complications. INTRODUCTION: Type 1 diabetes mellitus (T1DM) is associated with deteriorated bone architecture and impaired osseous healing potential; nonetheless, effective methods for resisting T1DM-associated osteopenia/osteoporosis and promoting bone defect/fracture healing are still lacking. PEMF, as a safe and noninvasive method, have proven to be effective for promoting osteogenesis, whereas the potential effects of PEMF on T1DM osteopathy remain poorly understood. METHODS: We herein investigated the effects of PEMF stimulation on bone architecture, mechanical properties, bone turnover, and its potential molecular mechanisms in alloxan-treated diabetic rabbits. We also developed novel nontoxic Ti2448 pTi implants with closer elastic modulus with natural bone and investigated the impacts of PEMF on pTi osseointegration for T1DM bone-defect repair. RESULTS: The deteriorations of cancellous and cortical bone architecture and tissue-level mechanical strength were attenuated by 8-week PEMF stimulation. PEMF also promoted osseointegration and stimulated more adequate bone ingrowths into the pore spaces of pTi in T1DM long-bone defects. Moreover, T1DM-associated reduction of bone formation was significantly attenuated by PEMF, whereas PEMF exerted no impacts on bone resorption. We also found PEMF-induced activation of osteoblastogenesis-related Wnt/β-catenin signaling in T1DM skeletons, but PEMF did not alter osteoclastogenesis-associated RANKL/RANK signaling gene expression. CONCLUSION: We reveal that PEMF improved bone architecture, mechanical properties, and pTi osseointegration by promoting bone anabolism through a canonical Wnt/β-catenin signaling-associated mechanism. This study enriches our basic knowledge for understanding skeletal sensitivity in response to external electromagnetic signals, and also opens new treatment alternatives for T1DM-associated osteopenia/osteoporosis and osseous defects in an easy and highly efficient manner.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Cai J, Li W, Sun T, et al. Pulsed electromagnetic fields preserve bone architecture and mechanical properties and stimulate porous implant osseointegration by promoting bone anabolism in type 1 diabetic rabbits. Osteoporos Int. 2018. PMID: 29523929. doi:10.1007/s00198-018-4392-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。