文献速递运动医学关节外科创伤骨科

膝关节前外侧关节外稳定结构:前外侧韧带与远端髂胫束Kaplan纤维的机器人切断研究

Anterolateral Knee Extra-articular Stabilizers: A Robotic Sectioning Study of the Anterolateral Ligament and Distal Iliotibial Band Kaplan Fibers.
PubMed 文献 · Am J Sports Med · 2018-03-20

在10对新鲜冷冻尸体膝关节(n=20)中,用6自由度机器人测试系统比较前交叉韧带(ACL)损伤膝中前外侧韧带(ALL)与Kaplan纤维切断对胫骨内旋、前胫骨平移和轴移的影响;两种结构均限制内旋,高屈曲角度(60°-90°)下切断Kaplan纤维较切断ALL导致更大内旋。

要点

  • ACL损伤膝中,ALL和Kaplan纤维均限制胫骨内旋。
  • 高屈曲角度(60°-90°)下,切断Kaplan纤维较切断ALL导致显著更大胫骨内旋。
  • 模拟轴移测试中,ALL和Kaplan纤维均限制内旋和前胫骨平移。

核心结论

  • ALL和Kaplan纤维在ACL损伤膝中限制内旋;高屈曲角度(60°-90°)下切断Kaplan纤维较切断ALL导致更大胫骨内旋;两者均参与限制轴移和前胫骨平移。

研究设计与样本

  • 控制性实验室研究,使用10对新鲜冷冻尸体膝关节(n=20),在ACL切断后随机切断ALL或Kaplan纤维,用6自由度机器人测试系统评估膝关节运动学。

主要发现

  • ACL切断较完整状态显著增加胫骨内旋(0°至90°)和前胫骨平移(30°和90°)。
  • 进一步切断ALL(15°-90°)和Kaplan纤维(15°、60°-90°)均显著增加内旋。
  • 高屈曲角度(60°-90°)下,切断Kaplan纤维较切断ALL导致显著更大内旋。
  • 模拟轴移测试中,切断ALL在15°和30°显著增加内旋和前平移;切断Kaplan纤维在15°和30°显著增加内旋、在15°显著增加前平移。
  • 模拟轴移测试或孤立前胫骨载荷下,ACL/ALL缺损与ACL/Kaplan纤维缺损状态间前胫骨平移无显著差异。

关键数值与推荐

  • 内旋扭矩5 N·m(0°-90°,每15°递增);模拟轴移为10 N·m外翻和5 N·m内旋扭矩(15°和30°);前胫骨载荷88 N(30°和90°)。

临床怎么用

  • 作者指出这些结果证明合并ACL与前外侧关节外膝关节损伤时旋转性膝关节松弛增加,并可能使外科医生优化对此类损伤模式患者的诊疗。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The individual kinematic roles of the anterolateral ligament (ALL) and the distal iliotibial band Kaplan fibers in the setting of anterior cruciate ligament (ACL) deficiency require further clarification. This will improve understanding of their potential contribution to residual anterolateral rotational laxity after ACL reconstruction and may influence selection of an anterolateral extra-articular reconstruction technique, which is currently a matter of debate. Hypothesis/Purpose: To compare the role of the ALL and the Kaplan fibers in stabilizing the knee against tibial internal rotation, anterior tibial translation, and the pivot shift in ACL-deficient knees. We hypothesized that the Kaplan fibers would provide greater tibial internal rotation restraint than the ALL in ACL-deficient knees and that both structures would provide restraint against internal rotation during a simulated pivot-shift test. STUDY DESIGN: Controlled laboratory study. METHODS: Ten paired fresh-frozen cadaveric knees (n = 20) were used to investigate the effect of sectioning the ALL and the Kaplan fibers in ACL-deficient knees with a 6 degrees of freedom robotic testing system. After ACL sectioning, sectioning was randomly performed for the ALL and the Kaplan fibers. An established robotic testing protocol was utilized to assess knee kinematics when the specimens were subjected to a 5-N·m internal rotation torque (0°-90° at 15° increments), a simulated pivot shift with 10-N·m valgus and 5-N·m internal rotation torque (15° and 30°), and an 88-N anterior tibial load (30° and 90°). RESULTS: Sectioning of the ACL led to significantly increased tibial internal rotation (from 0° to 90°) and anterior tibial translation (30° and 90°) as compared with the intact state. Significantly increased internal rotation occurred with further sectioning of the ALL (15°-90°) and Kaplan fibers (15°, 60°-90°). At higher flexion angles (60°-90°), sectioning the Kaplan fibers led to significantly greater internal rotation when compared with ALL sectioning. On simulated pivot-shift testing, ALL sectioning led to significantly increased internal rotation and anterior translation at 15° and 30°; sectioning of the Kaplan fibers led to significantly increased tibial internal rotation at 15° and 30° and anterior translation at 15°. No significant difference was found when anterior tibial translation was compared between the ACL/ALL- and ACL/Kaplan fiber-deficient states on simulated pivot-shift testing or isolated anterior tibial load. CONCLUSION: The ALL and Kaplan fibers restrain internal rotation in the ACL-deficient knee. Sectioning the Kaplan fibers led to greater tibial internal rotation at higher flexion angles (60°-90°) as compared with ALL sectioning. Additionally, the ALL and Kaplan fibers contribute to restraint of the pivot shift and anterior tibial translation in the ACL-deficient knee. CLINICAL RELEVANCE: This study reports that the ALL and distal iliotibial band Kaplan fibers restrain anterior tibial translation, internal rotation, and pivot shift in the ACL-deficient knee. Furthermore, sectioning the Kaplan fibers led to significantly greater tibial internal rotation when compared with ALL sectioning at high flexion angles. These results demonstrate increased rotational knee laxity with combined ACL and anterolateral extra-articular knee injuries and may allow surgeons to optimize the care of patients with this injury pattern.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Geeslin AG, Chahla J, Moatshe G, et al. Anterolateral Knee Extra-articular Stabilizers: A Robotic Sectioning Study of the Anterolateral Ligament and Distal Iliotibial Band Kaplan Fibers. Am J Sports Med. 2018. PMID: 29558208. doi:10.1177/0363546518759053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。