关节镜下肩袖修复联合三维生物胶原补片增强治疗中大型撕裂:一项随机对照研究
前瞻性随机对照研究纳入112例50至85岁中大型肩袖撕裂患者,比较单纯缝线桥技术与联合三维胶原增强的疗效。随访28.2个月,增强组再撕裂率13.7%显著低于对照组34.0%(P=0.02),但末次随访时两组UCLA和Constant评分无显著差异。
要点
- 三维胶原增强组再撕裂率13.7%,显著低于单纯缝线桥组的34.0%(P=0.02)。
- 术后12个月增强组UCLA评分28.1±1.9优于对照组26.9±2.1(P=0.002)。
- 末次随访两组UCLA评分(30.0±1.6 vs 29.4±1.9,P=0.052)无显著差异。
核心结论
- 三维胶原增强可为中大型肩袖撕裂提供有效治疗,带来显著功能改善,并可能降低再撕裂率。
- 该技术还可能促进新的腱骨形成,从而对腱骨愈合发挥显著作用。
研究设计与样本
- 前瞻性随机对照研究,证据等级2级。
- 连续纳入112例50至85岁接受肩袖修复的患者,对照组58例采用缝线桥技术,研究组54例采用缝线桥技术联合三维胶原增强。
- 所有患者随访28.2个月(范围24至36个月),最终104例完成末次随访。
主要发现
- 术后12个月,研究组UCLA肩关节评分28.1±1.9显著优于对照组26.9±2.1(P=0.002)。
- 术后12个月,研究组Constant评分87.1±3.2显著优于对照组84.9±4.2(P=0.003)。
- 末次随访时,两组UCLA肩关节评分无显著差异(对照组29.4±1.9 vs 研究组30.0±1.6,P=0.052)。
- 末次随访时,两组Constant评分无显著差异(对照组89.9±3.2 vs 研究组90.8±3.5,P=0.18)。
- 研究组再撕裂率13.7%,对照组34.0%,研究组显著低于对照组(P=0.02)。
关键数值与推荐
- 结构完整性方面,研究组获得良好I型再撕裂分级者18/51,对照组10/53(P=0.06)。
- 6例患者的腱骨界面活检显示,研究组较对照组有更多骨形成和更多排列整齐、直径更大的纤维。
- 两组均未观察到术中或术后并发症。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Due to the highly organized tissue and avascular nature of the rotator cuff, rotator cuff tears have limited ability to heal after the tendon is reinserted directly on the greater tubercle of the humerus. Consequently, retears are among the most common complications after rotator cuff repair. Augmentation of rotator cuff repairs with patches has been an active area of research in recent years to reduce retear rate. HYPOTHESIS: Graft augmentation with 3D collagen could prevent retears of the repaired tendon and improve tendon-bone healing in moderate to large rotator cuff tears. STUDY DESIGN: Randomized controlled study; Level of evidence, 2. METHODS: A prospective, randomized controlled study was performed in a consecutive series of 112 patients age 50 to 85 years who underwent rotator cuff repair with the suture-bridge technique (58 patients, control group) or the suture-bridge technique augmented with 3-dimensional (3D) collagen (54 patients, study group). All patients were followed for 28.2 months (range, 24-36 months). Visual analog scale score for pain, University of California Los Angeles (UCLA) shoulder score, and Constant score were determined. Magnetic resonance imaging was performed pre- and postoperatively (at a minimum of 24 months) to evaluate the integrity of the rotator cuff and the retear rate of the repaired tendon. Three patients in each group had biopsies at nearly 24 months after surgery with histological assessment and transmission electron microscopy. RESULTS: A total of 104 patients completed the final follow-up. At the 12-month follow-up, the UCLA shoulder score was 28.1 ± 1.9 in the study group, which was significantly better than that in the control group (26.9 ± 2.1, P = .002). The Constant score was also significantly better in the study group (87.1 ± 3.2) than in the control group (84.9 ± 4.2, P = .003). However, at the final follow-up, no significant differences were found in the UCLA shoulder scores (29.4 ± 1.9 in the control group and 30.0 ± 1.6 in the study group, P = .052) or Constant scores (89.9 ± 3.2 in the control group and 90.8 ± 3.5 in the study group, P = .18). In terms of structural integrity, more patients in the study group had a favorable type I retear grade (18/51) than in the control group (10/53) ( P = .06). The postoperative retear rate was 34.0% in the control group and 13.7% in the study group, thus indicating a significantly lower retear rate in the study group ( P = .02). Biopsy specimens of the tendon-bone interface in 6 patients revealed more bone formation and more aligned fibers with larger diameters in the study group than in the control group. No intraoperative or postoperative complications were noted in either group. CONCLUSION: 3D collagen augmentation could provide effective treatment of moderate to large rotator cuff tears, providing substantial functional improvement, and could reduce the retear rate. This technique could also promote new tendon-bone formation, thus exerting a prominent effect on tendon-bone healing.
引用
- Cai YZ, Zhang C, Jin RL, et al. Arthroscopic Rotator Cuff Repair With Graft Augmentation of 3-Dimensional Biological Collagen for Moderate to Large Tears: A Randomized Controlled Study. Am J Sports Med. 2018. PMID: 29533674. doi:10.1177/0363546518756978
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。