含碘伏切口膜减少髋部手术手术部位污染:一项前瞻性随机试验
该前瞻性随机试验纳入101例接受髋关节开放保关节手术的患者,比较切口前使用含碘伏黏性切口膜与不使用切口膜对切口部位细菌污染率和菌落数的影响。结果显示,手术结束时使用切口膜组12.0%的切口细菌培养阳性,不使用切口膜组为27.4%;控制术前定植等因素后,不使用切口膜的患者在皮肤闭合时及所有采样时间点细菌存在的可能性显著更高。
要点
- 手术结束时使用含碘伏黏性切口膜组切口细菌定植率为12.0%,不使用切口膜组为27.4%。
- 控制术前定植等因素后,不使用切口膜的患者在皮肤闭合时及所有采样时间点细菌存在的可能性显著更高。
- 部分不使用切口膜的患者皮肤细菌计数极高,作者提出若植入假体可能发生手术部位感染或假体周围关节感染。
主要发现
- 手术结束时,使用黏性切口膜组12.0%的切口细菌定植阳性,不使用黏性切口膜组27.4%阳性。
- 控制术前定植和其他因素后,不使用黏性切口膜的患者在皮肤闭合时及所有采样时间点细菌存在的可能性显著更高。
- 部分不使用黏性切口膜的患者皮肤细菌计数极高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Iodophor-impregnated adhesive incise drapes are widely used during surgeries for reducing surgical site contamination. There is little evidence to support the latter belief. This study evaluated the efficacy of iodophor-impregnated adhesive drapes for reducing bacterial contamination and counts at the incision site during hip surgery. METHODS: In this prospective, randomized clinical trial, we enrolled 101 patients undergoing open joint preservation procedure of the hip. Half the patients had the adhesive drape applied to the skin prior to incision, while the remainder underwent the same surgery without a drape. Culture swabs were taken from the surgical site at 5 points (preskin preparation, after skin preparation, postincision, before subcutaneous closure, prior to dressing application) and sent for culture and colony counts. Mixed-effects logistic regressions were used to estimate effects of time and drape application on contamination rate. RESULTS: At the conclusion of surgery, 12.0% of incisions with adhesive drapes and 27.4% without adhesive drapes were positive for bacterial colonization. When controlling for preoperative colonization and other factors, patients without adhesive drapes were significantly more likely to have bacteria present at the time of skin closure, and at all time points when swab cultures were taken. CONCLUSION: It appears that the iodophor-impregnated adhesive draping significantly reduces bacterial colonization of the incision. Bacterial count at the skin was extremely high in some patients in whom adhesive drapes were not used, raising the possibility that a subsequent surgical site infection or periprosthetic joint infection could arise had an implant been utilized.
引用
- Rezapoor M, Tan TL, Maltenfort MG, et al. Incise Draping Reduces the Rate of Contamination of the Surgical Site During Hip Surgery: A Prospective, Randomized Trial. J Arthroplasty. 2018. PMID: 29525345. doi:10.1016/j.arth.2018.01.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。