文献速递关节外科

无转子下截骨一期全髋关节置换术使用非骨水泥定制股骨柄治疗Crowe III和IV型髋关节脱位的最小10年结局

Minimum 10-Year Outcome of One-Stage Total Hip Arthroplasty Without Subtrochanteric Osteotomy Using a Cementless Custom Stem for Crowe III and IV Hip Dislocation.
PubMed 文献 · J Arthroplasty · 2018-02-21

本研究评估了98例连续无转子下截骨一期全髋关节置换术中的26例高位脱位髋(Crowe III型12髋、IV型14髋),平均随访16年(10-22年)。末次随访平均Harris髋关节评分86分,平均下肢不等长7±5毫米,6髋(23.1%)需翻修,15年假体无菌性松动生存率股骨柄87.5%、髋臼假体96.1%。作者认为定制柄可避免附加手术且中长期生存率令人鼓舞。

要点

  • 26例高位脱位髋行无转子下截骨一期全髋关节置换术,平均随访16年。
  • 末次随访平均Harris髋关节评分86分,平均下肢不等长7±5毫米。
  • 6髋(23.1%)翻修,15年股骨柄无菌性松动生存率87.5%,髋臼假体96.1%。

核心结论

  • 定制股骨柄提供的髓内匹配及髓外偏心距和前倾适应可避免高位发育性髋关节发育不良全髋关节置换术的附加手术。
  • 本组高脱位全髋关节置换术的临床功能和长期生存率令人鼓舞。

研究设计与样本

  • 98例连续无转子下截骨全髋关节置换术使用非骨水泥定制股骨柄,必要时联合序贯肌腱切断术和/或大转子截骨。
  • 其中26例高位脱位髋(Crowe III型12髋、IV型14髋)平均随访16年(10-22年)进行评估。

主要发现

  • 末次随访平均Harris髋关节评分86分(37-100)。
  • 平均下肢不等长7±5毫米(0-17)。
  • 发生2例(7.7%)暂时性神经麻痹(1例坐骨神经、1例股神经)。
  • 6髋(23.1%)需翻修。
  • 15年股骨柄因无菌性松动的Kaplan-Meier生存率为87.5%(95%CI 76.5-99.1),同期髋臼假体因无菌性松动免于翻修的生存率为96.1%(95%CI 92.7-99.9)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Options for total hip arthroplasty (THA) in high dislocated hips include subtrochanteric osteotomy (STO), high hip center positioning, and 2-stage surgery with progressive lowering using an external fixator before THA. We described the long-term results of 1-stage THA performed without STO, using a cementless customized stem associated if necessary with sequential tenotomies and/or greater trochanteric osteotomy. METHODS: Ninety-eight consecutive THA without STO were performed using this technique. Of those 98 hips, 26 hips with high dislocation (12 class III and 14 class IV according to the Crowe classification) were evaluated at an average follow-up of 16 (10-22) years. RESULTS: At the time of last follow-up, the mean Harris Hip Score was 86 points (37-100). The mean leg-length discrepancy was 7 ± 5 mm (0-17). Two transient (7.7%) nerve palsies (1 sciatic and 1 femoral) were notified. A revision was required for 6 hips (23.1%). Kaplan-Meier survivorship analysis at 15 years regarding aseptic loosening of the femoral component was 87.5% (95% confidence interval, 76.5-99.1). During the same period, acetabular implant survivorship free from revision for aseptic loosening was 96.1% (95% confidence interval, 92.7-99.9). CONCLUSION: The combination of intramedullary fit and extramedullary adaptation for offset and anteversion provided by the custom stem can avoid additional procedures associated to THA in high developmental dysplasia of the hip. The clinical function and long-term survival reported in this series is encouraging for THA performed in case of high hip dislocation.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hitz OF, Flecher X, Parratte S, et al. Minimum 10-Year Outcome of One-Stage Total Hip Arthroplasty Without Subtrochanteric Osteotomy Using a Cementless Custom Stem for Crowe III and IV Hip Dislocation. J Arthroplasty. 2018. PMID: 29573918. doi:10.1016/j.arth.2018.02.055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。