文献速递关节外科

高效空气微粒过滤器在初次全关节置换术中使用强制空气加温器时不影响急性感染率

High Efficiency Particulate Air Filters Do Not Affect Acute Infection Rates During Primary Total Joint Arthroplasty Using Forced Air Warmers.
PubMed 文献 · J Arthroplasty · 2018-02-05

该回顾性研究纳入单医疗系统2013年和2015年连续5405例初次全髋或全膝关节置换术患者,比较使用强制空气加温器(FAW)与带高效空气微粒过滤器的FAW(FAW-HEPA)后90天内感染率。结果显示两组总体感染率、手术部位感染率和假体周围关节感染率均无显著差异,回归模型未显示FAW是感染增加的独立危险因素。

要点

  • FAW组与FAW-HEPA组90天总体感染率分别为1.65%和1.61%,无显著差异(P > .99)。
  • 手术部位感染率FAW组1.18% vs FAW-HEPA组0.84%,无显著差异(P = .27)。
  • 假体周围关节感染率FAW组0.47% vs FAW-HEPA组0.77%,无显著差异(P = .22)。

核心结论

  • 在全关节置换术中,与FAW-HEPA装置相比,FAW与总体感染、手术部位感染或假体周围关节感染风险升高无相关性。

研究设计与样本

  • 单医疗系统回顾性研究,纳入2013年和2015年连续5405例初次全关节置换术患者,其中全髋关节置换术2419例、全膝关节置换术2986例;2013年2792例使用FAW,2015年2613例使用FAW-HEPA。

主要发现

  • FAW组与FAW-HEPA组总体感染率分别为1.65%(n = 46)和1.61%(n = 42),P > .99。
  • FAW组与FAW-HEPA组手术部位感染率分别为1.18%(n = 33)和0.84%(n = 22),P = .27。
  • FAW组与FAW-HEPA组假体周围关节感染率分别为0.47%(n = 13)和0.77%(n = 20),P = .22。
  • 回归模型未显示FAW是总体感染增加的独立危险因素(OR 1.00,95%CI 0.65-1.57,P = .97)。
  • 回归模型未显示FAW是手术部位感染增加的独立危险因素(OR 1.47,95%CI 0.83-2.58,P = .18)。

关键数值与推荐

  • 假体周围关节感染定义为需要关节切开翻修或符合肌肉骨骼感染学会(MSIS)标准。
  • 手术部位感染定义为需要抗生素或冲洗/清创的伤口并发症。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Studies have suggested that forced-air warmers (FAWs) increase contamination of the surgical site. In response, FAWs with high efficiency particulate air filters (FAW-HEPA) were introduced. This study compared infection rates following primary total joint arthroplasty (TJA) using FAW and FAW-HEPA. METHODS: Primary TJA patients at a single healthcare system were retrospectively reviewed. A total of 5405 THA (n = 2419) and TKA (n = 2986) consecutive cases in 2013 and 2015 were identified. Patients in 2013 (n = 2792) had procedures using FAW, while FAW-HEPA was used in 2015 (n = 2613). The primary outcome was overall infection rate within 90-days. Sub-categorization of infections as periprosthetic joint infection (PJI) or surgical site infection (SSI) was also conducted. PJI was defined as reoperation with arthrotomy or meeting Musculoskeletal Infection Society (MSIS) criteria. SSI was defined as wound complications requiring antibiotics or irrigation/debridement. RESULTS: The FAW and FAW-HEPA groups had similar rates of overall infection (1.65% [n = 46] vs 1.61% [n = 42], P > .99), SSI (1.18% [n = 33] vs 0.84% [n = 22], P = .27), and PJI (0.47% [n = 13] vs 0.77% [n = 20], P = .22). Regression models did not show FAW to be an independent risk factor for increased overall infection (odds ratio [OR] 1.00, 95% confidence interval [CI] 0.65-1.57, P = .97), SSI (OR 1.47, 95% CI 0.83-2.58, P = .18), or PJI (OR 0.53, 95% CI 0.25-1.13, P = .09). CONCLUSION: FAW were not correlated with a higher risk of overall infection, SSI, or PJI during TJA when compared to FAW-HEPA devices.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Curtis GL, Faour M, George J, et al. High Efficiency Particulate Air Filters Do Not Affect Acute Infection Rates During Primary Total Joint Arthroplasty Using Forced Air Warmers. J Arthroplasty. 2018. PMID: 29572038. doi:10.1016/j.arth.2018.01.069

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。