单髁膝关节置换翻修为全膝关节置换:单髁假体(金属背托型与全聚乙烯型)是否影响全膝关节置换?
回顾性研究比较金属背托(MB)与全聚乙烯(AP)胫骨假体单髁置换后翻修成全膝关节置换的假体需求、结局与再翻修。MB组骨关节炎进展为最常见失败模式(P=0.03),AP组为不明原因疼痛(P=0.011)且翻修更早(4.8±3.2 vs 8.2±4.5年,P=0.012)。MB组更少使用无垫块无柄的标准后交叉韧带保留型全膝关节置换(12/38[32%] vs 10/14[71%],P=0.013),更多使用胫骨柄(P=0.04)和后交叉韧带替代型聚乙烯(P=0.05),但7年全膝关节置换生存率无显著差异(70.3 vs 87.5,P=0.191)。
要点
- MB单髁翻修更常需胫骨柄和后交叉韧带替代型聚乙烯,AP翻修更早且多因疼痛失败。
- MB组使用无垫块无柄标准后交叉韧带保留型全膝关节置换的比例低于AP组(32% vs 71%,P=0.013)。
- 两组7年全膝关节置换生存率无显著差异(70.3 vs 87.5,P=0.191)。
核心结论
- 金属背托单髁假体增加复杂翻修需胫骨柄和后交叉韧带替代的概率,但较全聚乙烯假体降低早期翻修概率,后者常因疼痛早期失败。
研究设计与样本
- 回顾性研究纳入55例患者共60例单髁置换翻修为全膝关节置换,平均植入后7.3年(0.1至17年)翻修,平均年龄64岁(49-83岁),44%男性;金属背托44例,全聚乙烯16例。
主要发现
- 金属背托组骨关节炎进展为最常见失败模式(P=0.03),全聚乙烯组不明原因疼痛为最常见失败模式(P=0.011),且全聚乙烯组翻修更早(4.8±3.2 vs 8.2±4.5年,P=0.012)。
- 60例中56例(93%)使用非限制性全膝关节置换假体。
- 金属背托组使用无垫块无柄标准后交叉韧带保留型全膝关节置换的比例低于全聚乙烯组(12/38[32%] vs 10/14[71%],P=0.013)。
- 金属背托假体与更多胫骨柄使用相关(P=0.04),与更多后交叉韧带替代型聚乙烯使用相关(P=0.05);限制性假体使用无差异。
- 多因素分析显示胫骨截骨深度预测胫骨柄需求;7例再翻修,7年全膝关节置换生存率金属背托组70.3(95%CI 47.0至93.6),全聚乙烯组87.5(95%CI 64.6至100),P=0.191。
关键数值与推荐
- 金属背托组骨关节炎进展为最常见失败模式(P=0.03),全聚乙烯组不明原因疼痛为最常见失败模式(P=0.011)。
- 全聚乙烯组翻修时间4.8±3.2年 vs 金属背托组8.2±4.5年(P=0.012)。
- 金属背托组使用无垫块无柄标准后交叉韧带保留型全膝关节置换12/38(32%) vs 全聚乙烯组10/14(71%)(P=0.013)。
- 金属背托组7年全膝关节置换生存率70.3(95%CI 47.0至93.6) vs 全聚乙烯组87.5(95%CI 64.6至100)(P=0.191)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study is to investigate differences in implant requirement, outcomes, and re-revision when total knee arthroplasty (TKA) was performed following unicompartmental knee arthroplasties (UKAs) with metal-backed (MB) compared to all-polyethylene (AP) tibial components. METHODS: Retrospective study of 60 UKAs converted to 60 TKAs at mean 7.3 years (0.1 to 17) after implantation in 55 patients (mean age, 64 [49-83]; 44% male): 44 MB and 16 AP. TKA implant requirement was investigated in addition to mode of failure, Oxford Knee Score, and TKA survival at mean 5.4 years (0.5 to 17). RESULTS: Progression of osteoarthritis was the commonest mode of failure in MB UKAs (P = .03) and unexplained pain in AP (P = .011) where revisions were performed earlier (4.8 ± 3.2 vs 8.2 ± 4.5, P = .012). In 56 of 60 (93%) cases, unconstrained TKA implants were used. The use of standard cruciate-retaining TKAs without augments or stems was less likely following MB UKA compared to AP (12 of 38 [32%] vs 10/14 [71%], P = .013). Specifically MB UKA implants were associated with more tibial stem use (P = .04) and more use of cruciate-substituting polyethylene (P = .05). There was no difference in the use of constrained implants. Multivariate analysis showed tibial resection depth to predict stem requirement. Seven were re-revised giving 7-year TKA survival: from MB UKA 70.3 (95% CI, 47.0 to 93.6) and from AP UKA 87.5 (95% CI, 64.6 to 100; P = .191). CONCLUSION: MB UKA implants increase the chances of a complex revision requiring tibial stems and cruciate substitution but reduce the chances of early revision compared to AP UKA which often fail early with pain.
引用
- Scott CEH, Powell-Bowns MFR, MacDonald DJ, et al. Revision of Unicompartmental to Total Knee Arthroplasty: Does the Unicompartmental Implant (Metal-Backed vs All-Polyethylene) Impact the Total Knee Arthroplasty? J Arthroplasty. 2018. PMID: 29525342. doi:10.1016/j.arth.2018.02.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。