第四代氧化铝陶瓷对陶瓷全髋关节置换术的临床结局与轴承特异性并发症:单外科医生749髋至少5年随访系列
回顾性分析单外科医生使用第四代氧化铝陶瓷轴承的667例(749髋)初次全髋关节置换术,平均随访6.5年。Harris髋关节评分从术前45.6分改善至末次随访91.3分,6.5年因任何原因翻修生存率为98.6%(95%CI 97.7-99.5)。发现2例(0.3%)陶瓷内衬碎裂和48髋(6.4%)可闻及噪音,无陶瓷头碎裂。
要点
- 平均随访6.5年,Harris髋关节评分从45.6分改善至91.3分。
- 6.5年因任何原因翻修生存率为98.6%(95%CI 97.7-99.5)。
- 陶瓷内衬碎裂2例(0.3%),可闻及噪音48髋(6.4%),无陶瓷头碎裂。
核心结论
- Delta陶瓷对陶瓷全髋关节置换术在6.5年随访时具有高生存率,无影像学骨溶解证据。
- 但发现0.3%陶瓷内衬碎裂和6.4%可闻及噪音与Delta陶瓷使用相关。
研究设计与样本
- 回顾性分析667例(749髋)由单外科医生使用第四代氧化铝陶瓷轴承行初次全髋关节置换术的患者。
- 315例男性,352例女性,平均年龄54.2岁。
- 所有髋均使用同一设计的非骨水泥假体和BIOLOX Delta陶瓷,472髋(63%)使用36-mm头,227髋使用32-mm头。
- 平均随访6.5年(范围5至8年)。
主要发现
- 平均Harris髋关节评分从术前45.6分改善至末次随访91.3分。
- 除1个髋臼杯外所有髋臼杯及所有股骨柄均固定良好,末次随访无影像学骨溶解证据。
- 陶瓷内衬碎裂2例(0.3%),无陶瓷头碎裂。
- 48髋(6.4%)出现可闻及噪音(29例咔哒声和19例吱吱声),无患者需翻修。
- 其他并发症包括1例脱位、1例深部感染、3例髂腰肌腱炎和6例股骨假体周围骨折。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The purpose of this study is to evaluate the minimum 5-year outcomes and bearing-specific complications in a single surgeon series of fourth-generation alumina ceramic-on-ceramic total hip arthroplasties (THAs). METHODS: We retrospectively analyzed 667 patients (749 hips) who underwent primary THAs by a single surgeon using fourth-generation alumina ceramic bearings. There were 315 men and 352 women with a mean age of 54.2 years. The surgeon used cementless prostheses with an identical design and BIOLOX Delta ceramics in all hips, using a 36-mm head in 472 hips (63%) and a 32-mm head in 227. The mean follow-up duration was 6.5 years (range, 5 to 8 years). RESULTS: The mean Harris hip score improved from 45.6 points preoperatively to 91.3 points at final follow-up. All but 1 acetabular cup and all femoral stems were well fixed. No radiographic evidence of osteolysis was identified at final follow-up. There were 2 (0.3%) ceramic liner fractures and no ceramic head fractures. A total of 48 hips (6.4%) exhibited audible noise (29 clickings and 19 squeakings), but no patient required revision. Other complications were 1 dislocation, 1 deep infection, 3 iliopsoas tendonitis, and 6 periprosthetic femoral fractures. Kaplan-Meier survivorship for revision for any reason was 98.6% (95% confidence interval, 97.7-99.5) at 6.5 years. CONCLUSION: Delta ceramic-on-ceramic THAs had a high rate of survivorship without radiographic evidence of osteolysis at 6.5-year follow-up. However, we found 0.3% ceramic liner fractures and 6.4% audible noises associated with the use of Delta ceramics.
引用
- Lim SJ, Ryu HG, Eun HJ, et al. Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up. J Arthroplasty. 2018. PMID: 29599034. doi:10.1016/j.arth.2018.02.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。