疼痛变化多少才有意义?全关节置换术后疼痛视觉模拟量表最小临床重要差异的界定

How Much Pain Is Significant? Defining the Minimal Clinically Important Difference for the Visual Analog Scale for Pain After Total Joint Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-02-22

该研究纳入139例全髋关节置换术(THA)和165例全膝关节置换术(TKA)患者,住院期间同步采集疼痛视觉模拟量表(VAS-P)与疼痛变化Likert评分,采用线性混合模型计算与Likert评分相关的前后VAS-P均值差,以界定最小临床重要差异(MCID)。结果显示THA和TKA疼痛改善的MCID分别为-18.6 mm和-22.6 mm,疼痛加重的MCID分别为23.6 mm和29.1 mm。作者结论认为VAS-P的MCID取决于手术类型及疼痛是改善还是加重。

要点

  • THA疼痛改善的MCID为-18.6 mm,疼痛加重的MCID为23.6 mm。
  • TKA疼痛改善的MCID为-22.6 mm,疼痛加重的MCID为29.1 mm。
  • THA最小可检测变化为14.9 mm,TKA为16.1 mm。

核心结论

  • 在术后全关节置换术人群中,VAS-P的MCID变化取决于手术干预类型以及疼痛是改善还是加重。
  • THA和TKA患者疼痛改善的VAS-P变化分别为-18.6 mm和-22.6 mm,达到统计学显著,作者认为该阈值具有高特异性,可用于识别有临床意义的疼痛干预。

研究设计与样本

  • 研究收集了139例全髋关节置换术(THA)和165例全膝关节置换术(TKA)患者的术后疼痛评分。
  • 住院期间对每例患者同步测量VAS-P并记录疼痛变化的Likert评分。
  • 采用线性混合模型计算前一次与当前VAS-P的平均差值,并与Likert评分进行相关性分析,当患者报告至少轻微改善或加重时界定为MCID。
  • 使用报告「无变化」患者的VAS-P均值标准误计算最小可检测变化。

主要发现

  • THA的总体平均VAS-P为35.0 mm,平均最高VAS-P为50.4 mm。
  • TKA的总体平均VAS-P为42.6 mm,平均最高VAS-P为61.1 mm。
  • THA的VAS-P最小可检测变化为14.9 mm,TKA为16.1 mm。
  • THA和TKA疼痛改善的MCID分别为-18.6 mm和-22.6 mm,疼痛加重的MCID分别为23.6 mm和29.1 mm。

关键数值与推荐

  • THA疼痛改善的MCID为-18.6 mm,疼痛加重的MCID为23.6 mm。
  • TKA疼痛改善的MCID为-22.6 mm,疼痛加重的MCID为29.1 mm。
  • THA的VAS-P最小可检测变化为14.9 mm,TKA为16.1 mm。
  • THA总体平均VAS-P为35.0 mm,平均最高VAS-P为50.4 mm;TKA总体平均VAS-P为42.6 mm,平均最高VAS-P为61.1 mm。

临床怎么用

  • 作者认为,THA和TKA患者疼痛改善的VAS-P变化分别为-18.6 mm和-22.6 mm,达到统计学显著,该阈值具有高特异性,可用于识别有临床意义的疼痛干预。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The ability to detect changes in patient-perceived pain after total joint arthroplasty (TJA) is critical to manage postoperative pain. The minimal clinically important difference (MCID) for visual analog scale for pain (VAS-P) has not been investigated in this population. This study investigated the MCID for VAS-P in the TJA population. METHODS: Postoperative pain scores were collected on 139 total hip arthroplasty (THA) and 165 total knee arthroplasty (TKA) patients. VAS-P was measured and Likert scores for changes in pain recorded together throughout the hospitalization per patient. Using a linear mixed model, the mean difference between preceding and current VAS-P was calculated and correlated with Likert score, when the patient reported at least slight improvement or worsening in pain, defining the MCID. Minimal detectable change was calculated using the VAS-P standard error of the means for patients reporting "no change." RESULTS: For THA, the overall mean and average highest VAS-P were 35.0 mm and 50.4 mm, respectively. For TKA, the overall mean and average highest VAS-P were 42.6 mm and 61.1 mm, respectively. The minimal detectable change in VAS-P was 14.9 mm for THA and 16.1 mm for TKA. The MCID for THA and TKA pain improvement was -18.6 mm and -22.6 mm, respectively, and for worsening was 23.6 mm and 29.1 mm, respectively. CONCLUSION: In the postoperative TJA population, VAS-P MCID changes depend on the type of surgical intervention, and whether pain is improving or worsening. Statistically significant VAS-P, improving -18.6 mm and -22.6 mm for THA and TKA patients, respectively, sets a reasonable threshold to identify clinically meaningful pain intervention with high specificity.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Danoff JR, Goel R, Sutton R, et al. How Much Pain Is Significant? Defining the Minimal Clinically Important Difference for the Visual Analog Scale for Pain After Total Joint Arthroplasty. J Arthroplasty. 2018. PMID: 29567002. doi:10.1016/j.arth.2018.02.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。