该队列研究纳入疑似慢性髋关节假体周围感染(PJI)的疼痛性髋关节置换术后患者,分别采用超声引导16G细针穿刺(2012-2013年,16例)或手术室粗针穿刺(2013-2016年,29例)获取组织样本培养,以翻修手术组织活检为金标准。手术室粗针穿刺组织活检的敏感性、特异性、阳性预测值、阴性预测值分别为82%、100%、100%、90%,优于超声引导细针穿刺的33%、85%、33%、85%。

要点

  • 手术室粗针组织活检诊断慢性髋PJI的敏感性82%、特异性100%,超声引导细针活检分别为33%、85%。
  • 粗针组织活检联合滑液培养较单用滑液培养多诊断9%的PJI。
  • 无菌环境下获取多份优质组织活检有助于慢性髋PJI的诊断。

核心结论

  • 在无菌环境下获取多份优质组织活检有助于慢性髋PJI的诊断,其诊断准确性高于超声引导细针活检,也高于单用滑液培养。

研究设计与样本

  • 队列研究,纳入疑似慢性髋PJI的疼痛性髋关节置换术后患者,超声引导16G细针穿刺组16例(2012-2013年),手术室粗针穿刺组29例(2013-2016年),以翻修手术组织活检为金标准。

主要发现

  • 共31%(n=14)最终诊断为PJI。
  • 粗针组织活检联合滑液培养较单用滑液培养多诊断9%的PJI。
  • 超声引导细针活检组的敏感性33%、特异性85%、阳性预测值33%、阴性预测值85%、阳性似然比2.2、阴性似然比0.8。
  • 手术室粗针活检组的敏感性82%、特异性100%、阳性预测值100%、阴性预测值90%、阳性似然比无穷大、阴性似然比0.2。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Diagnosing a chronic prosthetic joint infection (PJI) can be challenging. We hypothesized that obtaining preoperative tissue samples for culture in hip arthroplasty will increase the likelihood of diagnosing an infection before revision surgery. The aim of this cohort study was to determine the diagnostic accuracy of 2 tissue acquiring biopsy strategies to diagnose a PJI. METHODS: Patients with a painful hip arthroplasty, in which a chronic PJI was suspected, were included. Tissue samples were obtained either by ultrasound guidance with a 16-Gauge needle (2012-2013) or in the operating room with a thick-bore needle (2013-2016). Revision surgery tissue biopsies were used as the gold standard. Sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were calculated. RESULTS: A total of 16 patients in the ultrasound cohort and 29 patients in the surgical cohort were included. Thirty-one percent (n = 14) were finally diagnosed with a PJI. The addition of thick bore needle tissue biopsies resulted in 9% more diagnosed PJIs compared with synovial fluid alone. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio was 33%, 85%, 33%, 85%, 2.2, and 0.8, respectively, for the ultrasound-guided biopsy cohort and 82%, 100%, 100%, 90%, infinite, and 0.2, respectively, for the surgical biopsy cohort. CONCLUSION: Obtaining multiple good quality tissue biopsies in a sterile environment will contribute to the diagnosis of a chronic PJI of the hip, with a higher diagnostic accuracy compared with ultrasound-guided thin needle biopsies and compared with synovial fluid culture alone.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Ottink KD, Wouthuyzen-Bakker M, Kampinga GA, et al. Puncture Protocol in the Diagnostic Work-Up of a Suspected Chronic Prosthetic Joint Infection of the Hip. J Arthroplasty. 2018. PMID: 29530521. doi:10.1016/j.arth.2018.01.072