增强现实技术在全髋关节置换术髋臼杯置入中应用的初步研究

A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-02-05

该前瞻性初步研究在54例患者56髋初次全髋关节置换术中,随机顺序使用量角器和AR-HIP系统测量髋臼杯置入角度,并与术后3个月CT测量比较。AR-HIP在影像学前倾角上比量角器更准确(2.7° vs 6.8°,平均差4.1°,95%CI 3.0-5.2,P<.0001),影像学外展角无统计学显著差异。作者认为AR-HIP提供更准确的置入角度信息,但需进一步研究确认其作为导航工具的效用。

要点

  • AR-HIP系统通过智能手机将髋臼杯图像叠加于手术野并显示置入角度。
  • 影像学前倾角测量误差AR-HIP为2.7° vs 量角器6.8°,平均差4.1°(95%CI 3.0-5.2,P<.0001)。
  • 影像学外展角测量误差AR-HIP为2.1° vs 量角器2.6°,平均差0.5°(95%CI -1.1至0.1,P=.13),无统计学显著差异。

核心结论

  • 在此初步研究中,AR-HIP系统在髋臼杯置入角度方面提供的信息比传统方法更准确。
  • 需要进一步研究以确认AR-HIP系统作为导航工具的效用。

研究设计与样本

  • 前瞻性初步研究,纳入54例患者56髋初次全髋关节置换术。
  • 术中随机顺序使用量角器和AR-HIP系统测量置入角度,术后3个月通过CT图像测量髋臼杯置入角度。
  • 主要结局为术中与术后CT测量值之差的绝对值。

主要发现

  • 影像学前倾角测量误差AR-HIP为2.7° vs 量角器6.8°,平均差4.1°(95%CI 3.0-5.2,P<.0001),AR-HIP更准确。
  • 影像学外展角测量误差AR-HIP为2.1° vs 量角器2.6°,平均差0.5°(95%CI -1.1至0.1,P=.13),无统计学显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需要进一步研究以确认AR-HIP系统作为导航工具的效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). METHODS: We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. RESULTS: The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). CONCLUSION: In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool.

来源:J Arthroplasty,查看原文。版权归原作者所有。