文献速递关节外科

运动学对线全膝关节置换术中的关节线调整改善功能活动但不改善患者满意度

Joint Line Modification in Kinematically Aligned Total Knee Arthroplasty Improves Functional Activity but Not Patient Satisfaction.
PubMed 文献 · J Arthroplasty · 2018-02-13

研究纳入45例运动学对线(KA)全膝关节置换术(TKA)患膝与45例机械对线(MA)TKA对照,术后平均31.6个月评估新KSS 2011、PCS和painDETECT评分。KA-TKA术后功能活动评分显著高于MA-TKA(P=0.047),但患者满意度评分无差异;多因素回归显示标准活动评分和PCS分别正向和负向影响满意度。

要点

  • KA-TKA术后功能活动评分显著高于MA-TKA(P=0.047),高级活动评分亦显著更高(P=0.003)。
  • KA-TKA未能影响患者满意度评分。
  • PCS是负向影响患者满意度的关键因素。

核心结论

  • KA-TKA中的关节线调整改善了功能活动,但未改善患者满意度。
  • PCS是负向影响患者满意度的关键因素。

研究设计与样本

  • 研究纳入45例(45膝)接受KA-TKA的患者,并匹配45例(45膝)接受MA-TKA的患者作为对照。
  • 术后平均31.6个月评估新KSS 2011、PCS和painDETECT评分,并进行组间比较。
  • 将全部90例患者数据合并进行二次多元回归分析,以识别影响患者满意度的术后变量。

主要发现

  • 新KSS 2011评估显示,两种TKA术前无显著差异,但KA-TKA术后功能活动评分显著高于MA-TKA(P=0.047)。
  • 功能活动评分4个类别中,KA-TKA的高级活动评分显著高于MA-TKA(P=0.003)。
  • 5项高级活动中,爬梯子/台阶凳评分在KA-TKA显著更高(P=0.004)。
  • KA-TKA未能影响患者满意度评分。
  • 多元回归分析显示,标准活动评分正向影响患者满意度,PCS负向影响患者满意度。

关键数值与推荐

  • KA-TKA术后功能活动评分显著高于MA-TKA(P=0.047)。
  • KA-TKA术后高级活动评分显著高于MA-TKA(P=0.003)。
  • KA-TKA爬梯子/台阶凳评分显著高于MA-TKA(P=0.004)。
  • KA-TKA与MA-TKA患者满意度评分无显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Joint line modification in kinematically aligned total knee arthroplasty (KA-TKA) is attracting attention in expectation of optimizing patient satisfaction after TKA. This study aimed to examine the effects of joint line modification on Pain Catastrophizing Scale (PCS), painDETECT score, and new Knee Society Score (KSS) 2011, all of which are robustly related to patient satisfaction. METHODS: The study enrolled 45 knees of 45 patients undergoing KA-TKA and a matched group of 45 knees of 45 patients undergoing mechanically aligned (MA) TKA as controls. At a mean of 31.6 months after TKA, new KSS 2011, PCS, and painDETECT score were assessed and compared between KA- and MA-TKA. Data from all 90 patients were pooled into one group for secondary multiple regression analysis to identify postoperative variables affecting patient satisfaction. RESULTS: Assessment with new KSS 2011 showed no significant differences between the 2 TKAs preoperatively, but functional activity score was significantly higher with KA-TKA than with MA-TKA postoperatively (P = .047). Among the 4 categories of functional activity score, advanced activity score was significantly higher with KA-TKA than with MA-TKA (P = .003). Of the 5 advanced activities, the score for climbing ladder/step stool was significantly greater with KA-TKA (P = .004). KA-TKA failed to influence patient satisfaction score. Multiple regression analysis revealed that standard activity score and PCS affected patient satisfaction positively and negatively, respectively. CONCLUSION: Joint line modification in KA-TKA improved functional activity but not patient satisfaction. PCS was a key element negatively affecting patient satisfaction.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Niki Y, Kobayashi S, Nagura T, et al. Joint Line Modification in Kinematically Aligned Total Knee Arthroplasty Improves Functional Activity but Not Patient Satisfaction. J Arthroplasty. 2018. PMID: 29506930. doi:10.1016/j.arth.2018.02.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。