文献速递关节外科

全膝关节置换术后康复中三种电刺激技术的系统评价

Systematic Review of Three Electrical Stimulation Techniques for Rehabilitation After Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-02-06

该系统评价纳入17项随机对照试验共1285例手术,定性分析显示神经肌肉电刺激(NMES)与股四头肌力量和功能恢复改善相关,经皮电神经刺激(TENS)和电针(EA)可提供术后镇痛,最大获益取决于优化的参数和干预方案。

要点

  • NMES与全膝关节置换术后更高的股四头肌力量和功能恢复相关,每日1-2次、持续4-6周、强度100-120 mA、频率30-100 Hz时恢复获益最大。
  • TENS在强度15-40 mA、频率70-150 Hz时提供全膝关节置换术后有效镇痛。
  • EA在强度2 mA、频率2 Hz时也可能提供全膝关节置换术后镇痛。

核心结论

  • 作为辅助手段,NMES和TENS可有效改善全膝关节置换术后康复且不引发显著不耐受,最大获益取决于优化的参数和干预方案。
  • EA可能是全膝关节置换术后镇痛的有效辅助手段。

研究设计与样本

  • 系统评价,检索PubMed、OVID和ScienceDirect数据库,按照PRISMA推荐选择和分析研究,对多项结局进行数据提取和定性综合。
  • 共分析17项随机对照试验、1285例手术:8项NMES研究(608例手术)、7项TENS研究(560例手术)、2项EA研究(117例手术)。

主要发现

  • 定性分析提示NMES与全膝关节置换术后更高的股四头肌力量和功能恢复相关。
  • 当刺激为每日1次或2次、持续4-6周、强度100-120 mA、频率30-100 Hz时恢复获益最大。
  • 电极应足够大(100-200 cm2)以减少不适。
  • TENS在强度15-40 mA、频率70-150 Hz时提供全膝关节置换术后有效镇痛。
  • EA在强度2 mA、频率2 Hz时也可能提供全膝关节置换术后镇痛。

关键数值与推荐

  • NMES优化参数:每日1次或2次,持续4-6周,强度100-120 mA,频率30-100 Hz,电极面积100-200 cm2。
  • TENS参数:强度15-40 mA,频率70-150 Hz。
  • EA参数:强度2 mA,频率2 Hz。

临床怎么用

  • 原文结论认为NMES和TENS作为辅助手段可有效改善全膝关节置换术后康复且不引发显著不耐受。
  • 原文结论认为EA可能是全膝关节置换术后镇痛的有效辅助手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The comparative effectiveness of neuromuscular electrical stimulation (NMES), transcutaneous electrical nerve stimulation (TENS), and electroacupuncture (EA) for improving patient rehabilitation following total knee arthroplasty (TKA) is controversial. Therefore we conducted this systematic review to assess the available evidence. METHODS: The PubMed, OVID, and ScienceDirect databases were comprehensively searched and studies were selected and analyzed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations. Data were extracted and qualitatively synthesized for several outcomes. RESULTS: Data were analyzed from 17 randomized controlled trials involving 1285 procedures: 8 NMES studies (608 procedures), 7 TENS studies (560 procedures), and 2 EA studies (117 procedures). Qualitative analysis suggested that NMES was associated with higher quadriceps strength and functional recovery after TKA. Recovery benefits were maximal when the stimulation was performed once or twice a day for 4-6 weeks at an intensity of 100-120 mA and frequency of 30-100 Hz. The electrode should be sufficiently large (100-200 cm2) to reduce discomfort. TENS at an intensity of 15-40 mA and frequency of 70-150 Hz provided effective analgesia after TKA. EA at an intensity of 2 mA and frequency of 2 Hz may also provide postoperative analgesia of TKA. CONCLUSION: As adjunct modalities, NMES and TENS can effectively improve rehabilitation after TKA without triggering significant intolerance, and maximal benefits depend on optimized parameters and intervention protocols. EA may be an effective adjunct modality for analgesia after TKA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Yue C, Zhang X, Zhu Y, et al. Systematic Review of Three Electrical Stimulation Techniques for Rehabilitation After Total Knee Arthroplasty. J Arthroplasty. 2018. PMID: 29530519. doi:10.1016/j.arth.2018.01.070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。