大型金属股骨头与高交联聚乙烯在5至13年随访中磨损低且并发症少
本研究评估107髋(93例,平均年龄76岁)采用非骨水泥髋臼假体、36或40毫米金属股骨头及电子束100千戈瑞辐照熔融高交联聚乙烯(XLPE)的磨损与并发症,平均随访8年(范围5-13年)。全队列中位线性磨损率为0.041毫米/年(95%CI 0.031-0.057),中位体积磨损率为34.6立方毫米/年(95%CI 31.4-53.5);36与40毫米头之间磨损无差异。3髋(2%)出现小型无症状骨溶解,3例(3%)脱位(2例早期、1例晚期)但均未翻修,无因松动翻修、无内衬断裂、无症状性桁端腐蚀。作者推荐更长期临床随访,并谨慎在其他更年轻人群中常规使用大型金属股骨头。
要点
- 全队列中位线性磨损率0.041毫米/年(95%CI 0.031-0.057),中位体积磨损率34.6立方毫米/年(95%CI 31.4-53.5)。
- 36与40毫米头之间线性或体积磨损无差异。
- 3髋(2%)出现小型无症状骨溶解,3例(3%)脱位但均未翻修,无内衬断裂、无松动翻修、无症状性桁端腐蚀。
核心结论
- 该髋臼假体与XLPE配合大型金属股骨头具有低线性与体积磨损率,大型金属股骨头未导致内衬断裂、松动或症状性桁端腐蚀,但作者推荐更长期临床随访研究并谨慎在其他更年轻人群中常规使用大型金属股骨头。
研究设计与样本
- 评估107髋(93例,平均年龄76岁)采用一种设计的非骨水泥髋臼假体、36毫米(90髋)或40毫米(17髋)金属股骨头及一种电子束100千戈瑞辐照熔融XLPE,平均随访8年(范围5-13年)。
- 线性与体积磨损由一家经验丰富实验室采用Martell法测量,并采用首末次法分析;标准X线片加Judet位用于检测假体周围骨溶解;临床记录用于确定脱位、内衬断裂和疼痛性桁端腐蚀等并发症。
- 股骨头尺寸选择基于包括感知脱位风险、髋臼假体外径尺寸和内衬可用性在内的若干因素。
主要发现
- 全队列中位线性磨损率为0.041毫米/年(95%CI 0.031-0.057),中位体积磨损率为34.6立方毫米/年(95%CI 31.4-53.5)。
- 在可用样本量下,36与40毫米头尺寸之间线性或体积磨损无差异。
- 3髋(2%)发现小型无症状骨溶解性病变。
- 3例(3%)患者发生脱位(2例早期和1例晚期),但均未行翻修。
- 无因松动翻修、无内衬断裂、无患者出现症状性桁端腐蚀。
关键数值与推荐
- 全队列中位线性磨损率0.041毫米/年(95%CI 0.031-0.057)。
- 全队列中位体积磨损率34.6立方毫米/年(95%CI 31.4-53.5)。
- 36与40毫米头尺寸之间线性或体积磨损无差异(原文未报告具体数值)。
- 小型无症状骨溶解性病变3髋(2%)。
- 脱位3例(3%),其中早期2例、晚期1例,均未翻修。
临床怎么用
- 作者推荐更长期临床随访研究。
- 作者建议在其他更年轻人群中谨慎常规使用大型金属股骨头。
局限性
- 原文未报告局限性;但作者在结论中推荐更长期临床随访研究,并 caution(谨慎)在其他更年轻人群中常规使用大型金属股骨头。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Highly cross-linked polyethylene (XLPE) is reported to have low rates of linear and volumetric wear at 10-14 years. In a prior study, larger (36 and 40 mm) femoral heads were associated with more volumetric wear, but there were only 12 hips with these heads. METHODS: We evaluated 107 hips (93 patients, with a mean age of 76 years) with one design of uncemented acetabular component, a 36 (90 hips) or 40 mm (17 hips) metal femoral head, and one electron beam 100 kGy irradiated and remelted XLPE at a mean follow-up of 8 years (range 5-13 years). Selection of these femoral heads was based on several factors, including the perceived risk of dislocation, the outer diameter size of the acetabular component, and liner availability. Measurements of linear and volumetric wear were performed in one experienced laboratory by the Martell method and analyzed using the first-to-last method. Standard radiographs, with additional Judet views, were used to detect periprosthetic osteolysis. Clinical records were used to determine the complications of dislocation, liner fracture, and painful trunnion corrosion. RESULTS: For the entire cohort, the median linear wear rate was 0.041 mm/y (95% confidence interval, 0.031-0.057) and the median volumetric wear rate was 34.6 mm3/y (95% confidence interval, 31.4-53.5). With the numbers available, there was no difference in linear or volumetric wear between the 36 and 40 mm head sizes. Small, asymptomatic osteolytic lesions were noted in 3 hips (2%). There were 3 patients (3%) with dislocation (2 early and 1 late), but these have not had a revision. There were no revisions for loosening, no liner fracture, and no patient with symptomatic trunnion corrosion. CONCLUSION: This acetabular component and XLPE with large metal heads had low rates of linear and volumetric wear. Large metal femoral heads did not lead to liner fracture, loosening, or symptomatic trunnion corrosion in this patient population. However, we recommend longer clinical follow-up studies and caution in the routine use of larger metal femoral heads in other, younger patient populations.
引用
- Lachiewicz PF, O'Dell JA, Martell JM, et al. Large Metal Heads and Highly Cross-Linked Polyethylene Provide Low Wear and Complications at 5-13 Years. J Arthroplasty. 2018. PMID: 29588121. doi:10.1016/j.arth.2018.02.063
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。