非骨水泥全髋关节置换术治疗Crowe III和IV型发育性髋关节发育不良:高位髋中心与模块化颈
本研究评估了84例Crowe III和IV型发育性髋关节发育不良(DDH)患者接受高位髋中心与模块化颈非骨水泥全髋关节置换术(THA)的长期效果。末次随访平均15.1年,临床评分良好,15年总体生存率为90.5%,仅2例无菌性松动。结论认为高位髋杯放置伴轻度内移是DDH患者的有效技术。
要点
- 84例Crowe III和IV型DDH患者行非骨水泥THA,平均随访15.1年,80例获得末次随访。
- 临床评分良好,15年总体生存率90.5%,仅2例无菌性松动。
- 平均旋转中心高度33±8 mm,内移30±5 mm,2例坐骨神经损伤(1例完全恢复)。
核心结论
- 高位髋杯放置伴轻度内移是DDH患者的有效技术。
- 良好的偏心距恢复、陶瓷对陶瓷界面和多孔髋臼杯可能提供持久结果,克服高位髋杯放置相关的关节反作用力增加效应。
研究设计与样本
- 评估84例Crowe III和IV型DDH的THA,最终随访15.1年。
- 所有患者接受相同非骨水泥植入物(模块化颈和陶瓷对陶瓷界面)和相同入路(高位髋杯放置伴轻度内移)。
- 临床评估采用Harris髋关节评分和Merle d'Aubigne and Postel评分,并进行影像学评估分析髋杯方位。
主要发现
- 末次随访时80例患者可获得,临床评分良好。
- 发生2例坐骨神经损伤,其中1例完全恢复。
- 15年总体生存率为90.5%,仅报告2例无菌性松动。
- 平均旋转中心高度为33±8 mm,内移为30±5 mm。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total hip arthroplasty (THA) in severe developmental dysplasia of the hip (DDH) is a challenging procedure. The most used techniques involve anatomic cup positioning, augmentation femoral osteotomy. However, anatomic cup positioning is not always feasible in severe DDH and osteotomy nonunion may ensue. The purpose of the study was to assess the survivorship, the hip score results, the radiological parameters (fixation, loosening, component position) of a large cohort of patients with Crowe III and IV DDH, treated with high hip center and modular necks THAs. METHODS: Eighty-four THAs in Crowe III and IV DDH were evaluated, achieving a final follow-up of 15.1 years. All the patients were treated with the same cementless implant (modular necks and ceramic-on-ceramic coupling) and the same approach (high cup placement with slight medialization). The patients were clinically evaluated (Harris Hip score and Merle d'Aubigne and Postel score). A radiographic evaluation was performed, analyzing the orientation of the cup. RESULTS: Eighty patients were available at the last follow-up. The clinical scores were good at the final follow-up. Two sciatic lesions occurred: one patient fully recovered. The overall survivorship was 90.5% at 15 years: only 2 cases of aseptic loosening were reported. The mean center of rotation height was 33 ± 8 mm and the medialization was 30 ± 5 mm. CONCLUSION: A high cup placement with slight medialization is a valid technique in DDH patients. A good restoration of the offset, ceramic-on-ceramic coupling and a porous socket may provide durable results, overcoming the effects of increasing joint reaction forces related to high cup placement.
引用
- Montalti M, Castagnini F, Giardina F, et al. Cementless Total Hip Arthroplasty in Crowe III and IV Dysplasia: High Hip Center and Modular Necks. J Arthroplasty. 2018. PMID: 29500091. doi:10.1016/j.arth.2018.01.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。