术前血糖控制可预测全关节置换术患者围手术期血糖水平
该回顾性研究纳入773例接受全关节置换术的糖尿病患者,通过约登指数分析确定术后血糖>200 mg/dL的A1c阈值为7.45%,并按A1c<7%、7.0-8.0%、>8.0%分组。术后平均血糖随A1c升高而增加(167 vs 240 vs 276 mg/dL,P<.0001),但假体周围关节感染率无统计学差异(2.25%、1.99%、4.55%,P=.4319)。作者推荐以A1c 7.45%作为阈值,并建议对A1c升高患者谨慎处理。
要点
- A1c>7.45%时术后血糖>200 mg/dL的可能性更大。
- 术后平均血糖随A1c分组升高:<7%组167 mg/dL,7.0-8.0%组240 mg/dL,>8.0%组276 mg/dL(P<.0001)。
- 假体周围关节感染率三组分别为2.25%、1.99%、4.55%,无统计学差异(P=.4319)。
核心结论
- 术前血红蛋白A1c水平与术后血糖水平相关。
- 作者推荐全关节置换术患者采用A1c 7.45%作为截断值,并建议对A1c升高的患者谨慎处理。
研究设计与样本
- 回顾性综述,纳入773例接受全关节置换术的糖尿病患者。
- 采用约登J计算分析确定术后血糖>200 mg/dL可能性更大的A1c值,并将患者分为A1c<7%、7.0-8.0%、>8.0%三组。
主要发现
- A1c>7.45%时术后高血糖>200 mg/dL的可能性更大。
- 术后平均血清血糖随A1c升高而增加:A1c<7%组167 mg/dL,A1c 7.0-8.0%组240 mg/dL,A1c>8.0%组276 mg/dL(P<.0001)。
- 假体周围关节感染率三组分别为2.25%、1.99%、4.55%,无统计学差异(P=.4319)。
关键数值与推荐
- A1c阈值为7.45%,高于此值时术后血糖>200 mg/dL可能性更大。
- 术后平均血糖:A1c<7%组167 mg/dL,A1c 7.0-8.0%组240 mg/dL,A1c>8.0%组276 mg/dL(P<.0001)。
- 假体周围关节感染率:A1c<7%组2.25%,A1c 7.0-8.0%组1.99%,A1c>8.0%组4.55%(P=.4319)。
临床怎么用
- 作者推荐全关节置换术患者使用A1c 7.45%作为截断值。
- 作者建议对A1c水平升高的全关节置换术患者谨慎处理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Diabetic patients undergoing total joint arthroplasty (TJA) with postoperative hyperglycemia >200 mg/dL have increased the risk of prosthetic joint infection (PJI). We investigated the correlation between preoperative hemoglobin A1c (A1c) and postoperative hyperglycemia in diabetic patients undergoing TJA. METHODS: A retrospective review of 773 diabetic patients undergoing TJA was conducted. A Youden's J computational analysis determined the A1c where postoperative glucose levels >200 mg/dL were statistically more likely. Patients were then stratified into 3 groups: A1c <7%, A1c 7.0-8.0%, and A1c >8.0%. Outcomes included the highest postoperative in-hospital serum glucose level and PJI. RESULTS: We determined an A1c >7.45% resulted in a greater chance of postoperative hyperglycemia >200 mg/dL. Average postoperative serum glucose increased with A1c (A1c < 7 = 167 mg/dL, A1c 7.0-8.0 = 240 mg/dL, and A1c > 8 = 276 mg/dL, P < .0001). PJI did not statistically increase with A1c (2.25%, 1.99%, and 4.55%, respectively, P = .4319). CONCLUSION: Preoperative hemoglobin A1c levels correlate with postoperative glucose levels. We recommend using an A1c cutoff of 7.45% for patients undergoing TJA and suggest that caution should be exercised in patients with elevated A1c levels undergoing TJA.
引用
- Godshaw BM, Ojard CA, Adams TM, et al. Preoperative Glycemic Control Predicts Perioperative Serum Glucose Levels in Patients Undergoing Total Joint Arthroplasty. J Arthroplasty. 2018. PMID: 29576485. doi:10.1016/j.arth.2018.02.071
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。