平衡型全膝关节置换术中屈膝中期不稳定的计算机模型研究

A Computer Model of Mid-Flexion Instability in a Balanced Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-02-21

本研究通过计算分析模拟后稳定型(PS)与保留交叉韧带型(CR)全膝关节置换术(TKA)的膝关节屈曲过程,发现胫股关节更偏近端及股骨更偏前的位置可显著降低屈膝15°-75°中期的胫股韧带总负荷(P < .001),而假体尺寸无显著影响(P > .1)。结论认为PS与CR TKA可在0°和90°屈膝时获得良好平衡,但在屈膝中期存在不稳定。

要点

  • 胫股关节更偏近端及股骨更偏前的位置使屈膝中期胫股韧带总负荷显著降低(P < .001)。
  • 假体尺寸对胫股韧带负荷无显著影响(P > .1)。
  • PS与CR TKA可在0°和90°屈膝时平衡良好,但屈膝中期存在不稳定。

核心结论

  • PS与CR TKA可在0°和90°屈膝时获得良好平衡,但在屈膝中期存在不稳定。
  • 抬高关节线并使股骨前移可导致膝关节在屈膝中期过松。

研究设计与样本

  • 计算分析模拟PS与CR TKA设计的膝关节屈曲过程。
  • 通过调整胫股近端-远端位置、股骨前后位置及假体尺寸模拟偏离理想假体位置的情况。

主要发现

  • 胫股关节更偏近端及股骨更偏前的位置使胫股韧带总负荷显著降低(P < .001)。
  • 假体尺寸对胫股韧带负荷无显著影响(P > .1)。
  • 假体设计与膝关节屈曲显著影响胫股韧带总负荷(P < .001),但与假体近端-远端位置的交互作用不显著(P > .2)。
  • 假体近端-远端位置在15°-75°屈膝范围内对PS与CR两种假体设计的影响相似。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Some patients have mid-flexion instability despite stability at 0° and 90° of flexion. This study aims to determine the effects of total knee arthroplasty (TKA) stability while changing femur implant size and position. METHODS: A computational analysis was performed simulating knee flexion of posterior stabilized (PS) and cruciate retaining (CR) TKA designs. Deviations from the ideal TKA implant position were simulated by adjusting tibiofemoral proximal-distal position and femur anterior-posterior position as well as implant size. Forces in ligaments connecting the femur and tibia were collected. Total tibiofemoral ligament load for mid-knee flexion of 15°-75° was analyzed vs proximal-distal implant position, implant size, implant design, and knee flexion for PS and CR knees. Posterior cruciate ligament load was also analyzed for CR knees. RESULTS: Total tibiofemoral ligament load was significantly reduced by a more proximal tibiofemoral and anterior femur position (P < .001). Implant size did not have a significant effect on tibiofemoral ligament load (P > .1). Implant design and knee flexion significantly influenced total tibiofemoral ligament load (P < .001), but the interactions with implant proximal-distal position were not significant (P > .2), indicating that implant proximal-distal position had a similar effect across the 15°-75° knee flexion range for both studied PS and CR implant designs. CONCLUSION: PS and CR TKA can be well-balanced at 0° and 90° knee flexion and have instability in mid-flexion. Elevating the joint line and shifting the femur anteriorly can cause the knee to be too loose in mid-flexion.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Evangelista PJ, Laster SK, Lenz NM, et al. A Computer Model of Mid-Flexion Instability in a Balanced Total Knee Arthroplasty. J Arthroplasty. 2018. PMID: 29567003. doi:10.1016/j.arth.2018.02.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。