胸部CT与DXA诊断椎体畸形对比常规侧位胸椎X线
本研究纳入87例受试者(平均年龄65岁,男性50例,COPD患者57例),比较X线、胸部CT与DXA诊断T4至L1椎体畸形的一致性。三种方法测高可重复性均优,受试者水平上CT和DXA的诊断性能提示可用于COPD患者椎体畸形的机会性筛查。
要点
- 三种影像测椎体高度可重复性优(ICC>0.94),观察者内一致性良好至优(kappa 0.64-0.77)。
- 椎体水平AUROC:CCT对比X线0.85,DXA对比X线0.74,DXA对比CCT 0.77。
- 受试者水平CT的PPV 79-82%、NPV 90-93%,DXA略低(PPV 73-77%、NPV 80-89%)。
核心结论
- 三种影像测椎体高度可重复性均优,受试者水平CT(PPV 79-82%;NPV 90-93%)和略低的DXA(PPV 73-77%;NPV 80-89%)提示可用于COPD患者椎体畸形的机会性筛查。
研究设计与样本
- 纳入87例受试者(平均年龄65岁;男性50例;COPD患者57例),均行X线、胸部CT(CCT)和DXA检查。
- 用SpineAnalyzer™软件对可评估椎体评分两次,计算ICC和kappa评估观察者内变异性。
- 计算敏感度、特异度、PPV、NPV和AUROC比较不同影像对T4至L1椎体畸形的诊断。
主要发现
- 高度测量ICC均>0.94,kappa 0.64-0.77。
- 椎体水平AUROC:CCT对比X线0.85,DXA对比X线0.74,DXA对比CCT 0.77。
- 敏感度51%-73%,PPV 57%-70%,特异度和NPV均≥96%。
- 受试者水平AUROC值与椎体水平相当。
关键数值与推荐
- 受试者水平CT:PPV 79-82%,NPV 90-93%。
- 受试者水平DXA:PPV 73-77%,NPV 80-89%。
- 椎体水平敏感度51%-73%,PPV 57%-70%,特异度和NPV≥96%。
临床怎么用
- 原文结论提示CT和DXA可用于COPD患者椎体畸形的机会性筛查,作者表述为「could be used」。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: X-ray, CT and DXA enable diagnosis of vertebral deformities. For this study, level of agreement of vertebral deformity diagnosis was analysed. We showed that especially on subject level, these imaging techniques could be used for opportunistic screening of vertebral deformities in COPD patients. INTRODUCTION: X-ray and CT are frequently used for pulmonary evaluation in patients with chronic obstructive pulmonary disease (COPD) and also enable to diagnose vertebral deformities together with dual-energy X-ray absorptiometry (DXA) imaging. The aim of this research was to study the level of agreement of these imaging modalities for diagnosis of vertebral deformities from T4 to L1. METHODS: Eighty-seven subjects (mean age of 65; 50 males; 57 COPD patients) who had X-ray, chest CT (CCT) and DXA were included. Evaluable vertebrae were scored twice using SpineAnalyzer™ software. ICCs and kappas were calculated to examine intra-observer variability. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the receiver operating characteristic curve (AUROC) were calculated to compare vertebral deformities diagnosed on the different imaging modalities. RESULTS: ICCs for height measurements were excellent (> 0.94). Kappas were good to excellent (0.64-0.77). At vertebral level, the AUROC was 0.85 for CCT vs. X-ray, 0.74 for DXA vs. X-ray and 0.77 for DXA vs. CCT. Sensitivity (51%-73%) and PPV (57%-70%) were fair to good; specificity and NPV were excellent (≥ 96%). At subject level, the AUROC values were comparable. CONCLUSIONS: Reproducibility of height measurements of vertebrae is excellent with all three imaging modalities. On subject level, diagnostic performance of CT (PPV 79-82%; NPV 90-93%), and to a slightly lesser extend of DXA (PPV 73-77%; NPV 80-89%), indicates that these imaging techniques could be used for opportunistic screening of vertebral deformities in COPD patients.
引用
- van Dort MJ, Romme EAPM, Smeenk FWJM, et al. Diagnosis of vertebral deformities on chest CT and DXA compared to routine lateral thoracic spine X-ray. Osteoporos Int. 2018. PMID: 29435620. doi:10.1007/s00198-018-4412-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。