文献速递关节外科

2017年Chitranjan S. Ranawat奖:膝关节置换术中计算机导航能否改善年轻患者的功能结局?一项随机研究

2017 Chitranjan S. Ranawat Award: Does Computer Navigation in Knee Arthroplasty Improve Functional Outcomes in Young Patients? A Randomized Study.
PubMed 文献 · Clin Orthop Relat Res · 2018-01-01

该随机试验纳入296例同期双侧全膝关节置换术(TKA)患者,一侧膝使用导航、另一侧不使用,平均随访15年时282例(95%)可获得数据。结果显示导航侧与非导航侧在膝关节协会评分、WOMAC评分、活动度、影像学对线及假体生存率(两组均为99%)方面均无显著差异;导航组出现11膝(4%)股骨前侧切迹而常规组无。作者不推荐广泛使用计算机导航。

要点

  • 平均随访15年时,导航侧与非导航侧在疼痛、功能、活动度及假体生存率(两组均为99%)上无显著差异。
  • 导航组股骨前侧切迹11膝(4%),常规组无(p=0.046)。
  • 作者不推荐广泛使用计算机导航,理由是其风险(本组观察到股骨切迹,他人观察到钉道骨折)和相关成本。

核心结论

  • 在这项随机试验中,至少14年随访数据显示,计算机导航在TKA中对疼痛、功能或生存率均无益处。
  • 除非其他长期随访研究确定导航在生存率、疼痛和功能方面有优势,否则作者不推荐广泛使用计算机导航,理由是其风险(本组观察到股骨切迹,他人观察到钉道骨折)和相关成本。

研究设计与样本

  • 随机试验,2000年10月至2002年10月期间纳入所有296例同期双侧TKA患者,一侧膝使用导航、另一侧不使用。
  • 平均随访15年(范围14-16年)时282例(95%)可获得数据;79%(223/282)为女性,初次置换时平均年龄59±7岁(范围48-64岁)。
  • 评估者与患者对治疗分组设盲。

主要发现

  • 15年随访时,膝关节协会膝关节评分导航侧92±8分 vs 非导航侧93±7分(95%CI 92-98;p=0.461),功能评分两组均为80±11分(95%CI 73-87;p=1.000),均无显著差异。
  • WOMAC评分导航侧14±7分 vs 非导航侧15±8分(95%CI 14-18;p=0.991),膝关节活动度导航侧128°±9° vs 非导航侧127°±10°(95%CI 100-140;p=0.780),UCLA活动评分两组均为6分(95%CI 4-8;p=1.000),均无显著差异。
  • 影像学(X线或CT)对线参数两组间无差异;无菌性松动频率两组无差异(p=0.918)。
  • 以翻修或无菌性松动为终点,Kaplan-Meier假体生存率15年时两组均为99%(95%CI 93-100;p=0.982)。
  • 股骨前侧切迹在计算机导航TKA组观察到11膝(4%),常规TKA组无(p=0.046)。

关键数值与推荐

  • 无菌性松动定义为任何假体周围完整透亮线宽度>1 mm或任何假体移位。
  • 膝关节协会膝关节评分导航侧92±8分 vs 非导航侧93±7分(95%CI 92-98;p=0.461)。
  • WOMAC评分导航侧14±7分 vs 非导航侧15±8分(95%CI 14-18;p=0.991)。
  • 假体生存率15年时两组均为99%(95%CI 93-100;p=0.982)。
  • 股骨前侧切迹导航组11膝(4%) vs 常规组无(p=0.046)。

临床怎么用

  • 作者不推荐广泛使用计算机导航TKA,因为其风险(本系列观察到股骨切迹;他人观察到钉道骨折)和相关成本。
  • 除非其他长期随访研究确定导航在生存率、疼痛和功能方面有优势。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Proponents of computer-assisted TKA suggest that better alignment of the TKAs will lead to improved long-term patient functional outcome and survivorship of the implants. However, there is little evidence about whether the improved position and alignment of the knee components obtained using computer navigation improve patient function and the longevity of the TKA. QUESTIONS/PURPOSES: The purpose of this study was to determine whether (1) clinical results; (2) radiographic and CT scan results; and (3) the survival rate of TKA components would be better in patients having computer-assisted TKA than results of patients having TKA without computer-assisted TKA. In addition, we determined whether (4) complication rates would be less in the patients with computer-assisted TKA than those in patients with conventional TKA. METHODS: We performed a randomized trial between October 2000 and October 2002 in patients undergoing same-day bilateral TKA; in this trial, one knee was operated on using navigation, and the other knee was operated on without navigation. All 296 patients who underwent same-day bilateral TKA during that period were enrolled. Of those, 282 patients (95%) were accounted for at a mean of 15 years (range, 14-16 years). A total of 79% (223 of 282) were women and the mean age of the patients at the time of index arthroplasty was 59 ± 7 years (range, 48-64 years). Knee Society knee score, WOMAC score, and UCLA activity score were obtained preoperatively and at latest followup. Radiographic measurements were performed including femorotibial angle, position of femoral and tibial components, level of joint line, and posterior condylar offset. Aseptic loosening was defined as a complete radiolucent line > 1 mm in width around any component or migration of any component. Assessors and patients were blind to treatment assignment. RESULTS: The Knee Society knee (92 ± 8 versus 93 ± 7 points; 95% confidence interval [CI], 92-98; p = 0.461) and function scores (80 ± 11 versus 80 ± 11 points; 95% CI, 73-87; p = 1.000), WOMAC score (14 ± 7 versus 15 ± 8 points; 95% CI, 14-18; p = 0.991), range of knee motion (128° ± 9° versus 127° ± 10°; 95% CI, 100-140; p = 0.780), and UCLA patient activity score (6 versus 6 points; 95% CI, 4-8; p = 1.000) were not different between the two groups at 15 years followup. There were no differences in any radiographic parameters of alignment (on radiography or CT scan) between the two groups. The frequency of aseptic loosening was not different between the two groups (p = 0.918). Kaplan-Meier survivorship of the TKA components was 99% in both groups (95% CI, 93-100) at 15 years as the endpoint of revision or aseptic loosening (p = 0.982). Anterior femoral notching was observed in 11 knees (4%) in the computer-assisted TKA group and none in the conventional TKA group (p = 0.046). CONCLUSIONS: In this randomized trial, with data presented at a minimum of 14 years of followup, we found no benefit to computer navigation in TKA in terms of pain, function, or survivorship. Unless another study at long-term followup identifies an advantage to survivorship, pain, and function, we do not recommend the widespread use of computer navigation in TKA because of its risks (in this series, we observed femoral notching; others have observed pin site fractures) and attendant costs. LEVEL OF EVIDENCE: Level I, therapeutic study.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Kim YH, Park JW, Kim JS, et al. 2017 Chitranjan S. Ranawat Award: Does Computer Navigation in Knee Arthroplasty Improve Functional Outcomes in Young Patients? A Randomized Study. Clin Orthop Relat Res. 2018. PMID: 29389753. doi:10.1007/s11999.0000000000000000

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。