全髋关节置换术中负重面材料对假体周围关节感染风险的影响:系统综述与Meta分析
该系统综述与Meta分析检索了Medline、Embase、Cochrane图书馆、Web of Science及CINAHL等数据库,纳入17项比较不同负重面材料全髋关节置换术后假体周围关节感染(PJI)发生率的对照研究(11项随机对照试验和6项观察性研究)。所有研究中PJI总体累积发生率为0.78%(1514/193378),MoP为0.85%(1353/158430)、CoP为0.38%(67/17489)、CoC为0.53%(94/17459)。Meta分析显示三种负重面组合之间PJI风险无显著差异,现有临床研究无证据表明负重面选择影响PJI风险。
要点
- 所有研究中全髋关节置换术后PJI总体累积发生率为0.78%(1514/193378)。
- MoP的PJI发生率为0.85%(1353/158430),CoP为0.38%(67/17489),CoC为0.53%(94/17459)。
- Meta分析显示三种负重面组合之间PJI风险无显著差异,无证据表明负重面选择影响PJI风险。
核心结论
- 基于现有临床研究,无证据表明负重面选择影响全髋关节置换术后PJI风险。
- 未来研究包括基础科学研究和大样本、充分对照的登记研究,可能有助于确定植入物材料是否在关节置换术后PJI风险中起作用。
研究设计与样本
- 系统综述与Meta分析,检索Medline、Embase、Cochrane图书馆、Web of Science和Cumulative Index of Nursing and Allied Health Literature数据库,纳入报告不同负重面PJI发生率的对照随机和观察性研究。
- 共检索到2272项研究,17项符合纳入标准并进行分析,包括11项随机对照试验和6项观察性研究。
- 两名研究者独立审查研究资格、评估偏倚风险并进行数据提取,采用Mantel-Haenszel法和随机效应模型按Cochrane协作组方法进行Meta分析。
主要发现
- 纳入研究总体质量高,但观察性研究因对混杂因素调整不充分而存在高偏倚风险。
- 所有研究中PJI总体累积发生率为0.78%(1514/193378)。
- MoP的PJI总体发生率为0.85%(1353/158430),CoP为0.38%(67/17489),CoC为0.53%(94/17459)。
- Meta分析显示三种负重面组合之间PJI风险无显著差异。
局限性
- 观察性研究因对混杂因素调整不充分而存在高偏倚风险。
- 未来研究包括基础科学研究和大样本、充分对照的登记研究,可能有助于确定植入物材料是否在关节置换术后PJI风险中起作用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Periprosthetic joint infection (PJI) is a serious complication of total hip arthroplasty (THA). Different bearing surface materials have different surface properties and it has been suggested that the choice of bearing surface may influence the risk of PJI after THA. The objective of this meta-analysis was to compare the rate of PJI between metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and ceramic-on-ceramic (CoC) bearings. PATIENTS AND METHODS: Electronic databases (Medline, Embase, Cochrane library, Web of Science, and Cumulative Index of Nursing and Allied Health Literature) were searched for comparative randomized and observational studies that reported the incidence of PJI for different bearing surfaces. Two investigators independently reviewed studies for eligibility, evaluated risk of bias, and performed data extraction. Meta-analysis was performed using the Mantel-Haenzel method and random-effects model in accordance with methods of the Cochrane group. RESULTS: Our search strategy revealed 2272 studies, of which 17 met the inclusion criteria and were analyzed. These comprised 11 randomized controlled trials and six observational studies. The overall quality of included studies was high but the observational studies were at high risk of bias due to inadequate adjustment for confounding factors. The overall cumulative incidence of PJI across all studies was 0.78% (1514/193 378). For each bearing combination, the overall incidence was as follows: MoP 0.85% (1353/158 430); CoP 0.38% (67/17 489); and CoC 0.53% (94/17 459). The meta-analysis showed no significant difference between the three bearing combinations in terms of risk of PJI. CONCLUSION: On the basis of the clinical studies available, there is no evidence that bearing choice influences the risk of PJI. Future research, including basic science studies and large, adequately controlled registry studies, may be helpful in determining whether implant materials play a role in determining the risk of PJI following arthroplasty surgery. Cite this article: Bone Joint J 2018;100-B:134-42.
引用
- Hexter AT, Hislop SM, Blunn GW, et al. The effect of bearing surface on risk of periprosthetic joint infection in total hip arthroplasty: a systematic review and meta-analysis. Bone Joint J. 2018. PMID: 29437054. doi:10.1302/0301-620X.100B2.BJJ-2017-0575.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。