文献速递关节外科

α-防御素检测在金属对金属轴承失败或头颈交界腐蚀继发不良局部组织反应中诊断假体周围关节感染的准确性

The Alpha-Defensin Test for Diagnosing Periprosthetic Joint Infection in the Setting of an Adverse Local Tissue Reaction Secondary to a Failed Metal-on-Metal Bearing or Corrosion at the Head-Neck Junction.
PubMed 文献 · J Arthroplasty · 2018-01-16

这项多中心回顾性研究纳入26例因金属对金属轴承失败或头颈交界腐蚀继发不良局部组织反应(ALTR)的患者,评估滑液α-防御素检测诊断假体周围关节感染(PJI)的准确性。26例中仅1例符合肌肉骨骼感染学会(MSIS)PJI标准,但9例α-防御素阳性,其中8例为假阳性(31%)。作者认为α-防御素检测在ALTR情况下易出现假阳性,推荐在翻修术前对所有ALTR髋关节行常规穿刺液检查以综合判断。

要点

  • 26例ALTR患者中仅1例符合MSIS的PJI标准,α-防御素阳性9例中8例为假阳性(31%)。
  • 8例假阳性均同时Synovasure阳性,其中5例报告提示滑液C反应蛋白低可能导致假阳性。
  • 作者推荐ALTR患者翻修术前常规行关节穿刺,综合滑液白细胞计数、分类、培养及α-防御素等辅助检查排除PJI。

核心结论

  • 与滑液白细胞计数类似,α-防御素检测在ALTR情况下易出现假阳性结果。
  • 作者推荐对ALTR髋关节在翻修术前常规行关节穿刺,综合滑液白细胞计数、分类、培养及α-防御素等辅助检查以在术前准确诊断PJI。

研究设计与样本

  • 多中心回顾性研究,回顾3个中心26例ALTR患者的病历,所有患者均行α-防御素检测。
  • 采用肌肉骨骼感染学会(MSIS)标准评估PJI。
  • 26例中13例为金属对金属全髋关节置换,9例为头颈交界腐蚀继发ALTR,4例为金属对金属髋关节表面置换。

主要发现

  • 26例中仅1例符合MSIS的PJI标准。
  • 9例髋关节α-防御素阳性,包括1例真阳性和8例假阳性(31%)。
  • 8例假阳性均同时Synovasure阳性,其中5例附带警告称滑液C反应蛋白值低可能导致假阳性。

关键数值与推荐

  • 26例ALTR患者中仅1例符合MSIS的PJI标准。
  • α-防御素阳性9例,其中假阳性8例(31%)。
  • 8例假阳性均Synovasure阳性,5例附带滑液C反应蛋白低可能导致假阳性的警告。

临床怎么用

  • 作者推荐对ALTR髋关节在翻修术前常规行关节穿刺,综合滑液白细胞计数、分类、培养及α-防御素等辅助检查以在术前准确诊断PJI。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In patients with adverse local tissue reaction (ALTR) secondary to a failed metal-on-metal (MoM) bearing or corrosion at the head-neck junction in a metal-on-polyethylene bearing, ruling in or out periprosthetic joint infection (PJI) can be challenging. Alpha-defensin has emerged as an accurate test for PJI. The purpose of this multicenter, retrospective study was to evaluate the accuracy of the alpha-defensin synovial fluid test in detecting PJI in patients with ALTR. METHODS: We reviewed medical records of 26 patients from 3 centers with ALTR that had an alpha-defensin test performed. Patients were assessed for PJI using the Musculoskeletal Infection Society criteria. Thirteen of these subjects had MoM total hip arthroplasty, 9 had ALTR secondary to head-neck corrosion, and 4 had MoM hip resurfacing. RESULTS: Only 1 of the 26 patients met Musculoskeletal Infection Society criteria for infection. However, 9 hips were alpha-defensin positive, including 1 true positive and 8 that were falsely positive (31%). All 8 of the false positives were also Synovasure positive, although 5 of 8 had an accompanying warning stating the results may be falsely positive due to a low synovial C-reactive protein value. CONCLUSION: Similar to synovial fluid white blood cell count, alpha-defensin testing is prone to false-positive results in the setting of ALTR. Therefore, we recommend an aggressive approach to ruling out PJI including routine aspiration of all hips with ALTR before revision surgery to integrate the synovial fluid blood cell count, differential, cultures and adjunctive tests like alpha-defensin to allow for accurate diagnosis preoperatively.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Okroj KT, Calkins TE, Kayupov E, et al. The Alpha-Defensin Test for Diagnosing Periprosthetic Joint Infection in the Setting of an Adverse Local Tissue Reaction Secondary to a Failed Metal-on-Metal Bearing or Corrosion at the Head-Neck Junction. J Arthroplasty. 2018. PMID: 29452973. doi:10.1016/j.arth.2018.01.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。