下一代测序能否在检测滑液病原体中发挥作用?
这项前瞻性单盲研究对86份髋或膝关节假体周围感染检查中获取的匿名滑液样本,在常规滑液检测(C反应蛋白、人中性粒细胞弹性蛋白酶、中性粒细胞总数、α-防御素及培养)后行下一代测序。结果显示下一代测序可识别培养阳性和培养阴性滑液样本中引起假体周围感染的病原体。
要点
- 86份滑液样本中,α-防御素阳性且培养阳性30份(I组),α-防御素阳性且培养阴性24份(II组),α-防御素阴性且培养阴性32份(III组)。
- I组中下一代测序与25份结果一致,其中4份检出培养未检出的抗生素耐药菌。
- 共10份样本下一代测序阳性而培养阴性,其中5份α-防御素阳性且炎症标志物水平高,另5份α-防御素阴性且炎症标志物水平低。
核心结论
- 下一代测序可识别培养阳性和培养阴性滑液样本中引起假体周围感染的病原体。
研究设计与样本
- 前瞻性单盲研究,纳入86份因假体周围感染检查行髋或膝关节穿刺获取的匿名滑液样本。
- 样本先行C反应蛋白、人中性粒细胞弹性蛋白酶、中性粒细胞总数、α-防御素及培养检测,再行下一代测序。
主要发现
- 86份样本中,I组(α-防御素阳性且培养阳性)30份,II组(α-防御素阳性且培养阴性)24份,III组(α-防御素阴性且培养阴性)32份。
- I组中下一代测序与25份结果一致,其中4份检出抗生素耐药菌而培养未检出。
- 另4份炎症标志物水平相对较低的样本培养阳性但下一代测序阴性。
- 共10份样本下一代测序阳性而培养阴性,其中5份α-防御素阳性且炎症标志物水平高,另5份α-防御素阴性且炎症标志物水平低。
- 多数感染概率较高的样本中下一代测序检出多种微生物但存在优势菌,而推测未感染的样本中检出多种微生物且无优势菌。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The diagnosis of periprosthetic joint infection can be difficult due to the high rate of culture-negative infections. The aim of this study was to assess the use of next-generation sequencing for detecting organisms in synovial fluid. MATERIALS AND METHODS: In this prospective, single-blinded study, 86 anonymized samples of synovial fluid were obtained from patients undergoing aspiration of the hip or knee as part of the investigation of a periprosthetic infection. A panel of synovial fluid tests, including levels of C-reactive protein, human neutrophil elastase, total neutrophil count, alpha-defensin, and culture were performed prior to next-generation sequencing. RESULTS: Of these 86 samples, 30 were alpha-defensin-positive and culture-positive (Group I), 24 were alpha-defensin-positive and culture-negative (Group II) and 32 were alpha-defensin-negative and culture-negative (Group III). Next-generation sequencing was concordant with 25 results for Group I. In four of these, it detected antibiotic resistant bacteria whereas culture did not. In another four samples with relatively low levels of inflammatory biomarkers, culture was positive but next-generation sequencing was negative. A total of ten samples had a positive next-generation sequencing result and a negative culture. In five of these, alpha-defensin was positive and the levels of inflammatory markers were high. In the other five, alpha-defensin was negative and the levels of inflammatory markers were low. While next-generation sequencing detected several organisms in each sample, in most samples with a higher probability of infection, there was a predominant organism present, while in those presumed not to be infected, many organisms were identified with no predominant organism. CONCLUSION: Pathogens causing periprosthetic infection in both culture-positive and culture-negative samples of synovial fluid could be identified by next-generation sequencing. Cite this article: Bone Joint J 2018;100-B:127-33.
引用
- Tarabichi M, Shohat N, Goswami K, et al. Can next generation sequencing play a role in detecting pathogens in synovial fluid? Bone Joint J. 2018. PMID: 29437053. doi:10.1302/0301-620X.100B2.BJJ-2017-0531.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。