导航计算机辅助与传统全膝关节置换术的十二年随访:一项前瞻性随机对照试验
一项前瞻性随机试验比较100例传统全膝关节置换术(CONV组)与100例计算机辅助全膝关节置换术(NAV组)术后平均12年的结局。结果显示两组假体生存率无显著差异(CONV组91.5% vs NAV组98.2%,P=.181),影像学精度与临床评分亦无显著差异。
要点
- 术后12年假体生存率CONV组91.5% vs NAV组98.2%,差异无统计学意义(P=.181)。
- 术后5年随访以来两组均未再行翻修手术。
- 影像学精度与临床评分在两组间均无显著差异(P≥.068与P≥.204)。
核心结论
- 术后12年,传统TKA与导航计算机辅助TKA在长期生存率、植入精度、临床结局或评分结果方面均未发现差异。
研究设计与样本
- 前瞻性随机对照试验,纳入100例传统TKA(CONV组)与100例计算机辅助TKA(NAV组),术后平均随访12年。
主要发现
- 随访率至少75%,术后12年假体生存率CONV组91.5% vs NAV组98.2%(P=.181),差异无统计学意义。
- 自5年随访以来两组均未再行TKA翻修。
- CONV组下肢中立轴不准确度1.8°±1.4° vs NAV组1.6°±1.7°(P=.700),差异无统计学意义。
- 所有X线评估在两组间均无显著差异(P≥.068)。
- 临床检查评估无差异(P≥.204),所有收集的结局评分结果相似(P≥.222)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Navigated computer-assisted total knee arthroplasty (TKA) was introduced to expedite long-term survival based on improved postoperative implantation accuracy. However, long-term outcome data after 10 years or more are rare, even available meta-analyses show controversial study results. METHODS: In a prospective randomized trial, 100 conventional TKAs (group CONV) were compared with 100 computer-assisted TKAs (group NAV) after a mean follow-up of 12 years postoperatively. A long-leg weight-bearing X-ray was performed for measuring mechanical axis of the limb, lateral distal femoral angle, and medial proximal tibial angle. Tibial slope, patella alpha angle, and radiolucent lines were also observed. Clinical investigation included evaluation of 4 different scores: Insall Knee Score, Western Ontario and MacMaster University Index score, Hospital for Special Surgery Knee Score, and visual analog scale. RESULTS: Based on a follow-up rate of at least 75%, no difference in TKA survival was found 12 years postoperatively: 91.5% in group CONV vs 98.2% in group NAV (P = .181). Since 5-year follow-up, no additional TKA revision had been performed in both groups. Group CONV showed a nonsignificant higher inaccuracy of neutral lower limb axis (1.8° ± 1.4°) compared to group NAV (1.6° ± 1.7°, P = .700). All X-ray assessments were not significant different within both study groups (P ≥ .068). Clinical examination showed no differences in evaluations (P ≥ .204). All collected outcome score results were similar (P ≥ .222). CONCLUSION: Twelve years postoperatively, no differences were found in terms of long-term survival, implantation accuracy, clinical outcome or score results.
引用
- Cip J, Obwegeser F, Benesch T, et al. Twelve-Year Follow-Up of Navigated Computer-Assisted Versus Conventional Total Knee Arthroplasty: A Prospective Randomized Comparative Trial. J Arthroplasty. 2017. PMID: 29426792. doi:10.1016/j.arth.2017.12.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。