二硫苏糖醇治疗是否比超声振荡更有效地诊断假体周围关节感染?
这项随机研究纳入232例接受膝关节或髋关节置换翻修术的患者,比较二硫苏糖醇(DTT)处理与超声振荡对假体周围关节感染(PJI)的诊断效能。结果显示,超声振荡和DTT液体培养的敏感性(分别为89%和91%)均高于标准组织培养(79%;p < 0.001)。在术前未怀疑感染的患者中,DTT的敏感性高于超声振荡和组织培养(100% vs 70%和50%;p < 0.001);在术前怀疑感染的患者中,DTT和超声振荡的敏感性均不高于标准培养(89%和94% vs 86%)。
要点
- 超声振荡和DTT液体培养诊断PJI的敏感性均高于标准组织培养。
- 术前未怀疑感染时,DTT敏感性高于超声振荡和组织培养。
- 术前怀疑感染时,DTT和超声振荡敏感性均不高于标准培养。
核心结论
- 在这项随机研究中,DTT与超声振荡检测PJI的敏感性无差异,且两者均比标准组织培养更敏感。
- 因此,超声振荡或DTT液体培养应被视为标准培养之外定义PJI的重要附加工具,并应与其他标准结合考虑,尤其是在翻修术前未怀疑感染的情况下。
研究设计与样本
- 前瞻性随机研究,纳入232例接受膝关节或髋关节置换翻修术的患者。
- 每例患者取5份组织样本进行培养,并随机分配至超声振荡组(117例)或DTT组(115例)进行假体处理液体培养。
- 以美国肌肉骨骼感染学会(Musculoskeletal Infection Society)的PJI定义为参考标准。
主要发现
- 超声振荡液体培养敏感性为89%,DTT液体培养敏感性为91%,均高于标准组织培养的79%(p < 0.001)。
- 术前未怀疑感染的患者中,DTT敏感性为100%,高于超声振荡的70%和组织培养的50%(p < 0.001)。
- 术前怀疑感染的患者中,DTT敏感性为89%,超声振荡为94%,均不高于标准培养的86%。
关键数值与推荐
- 以美国肌肉骨骼感染学会(Musculoskeletal Infection Society)的PJI定义作为参考标准。
- 证据等级为Level I,诊断性研究。
临床怎么用
- 作者认为,超声振荡或DTT液体培养应被视为标准培养之外定义PJI的重要附加工具,并应与其他标准结合考虑,尤其是在翻修术前未怀疑感染的情况下。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prosthetic joint infection (PJI) is among the most-severe complications of a total joint arthroplasty. Identification of the causal organism is of paramount importance for successful treatment, and sonication of implants may aid in this identification. Dithiothreitol (DTT) treatment has been proposed as an alternative to sonication to improve diagnosis, reduce costs, and improve reliability of the procedure, but its efficacy remains poorly characterized. QUESTIONS/PURPOSES: (1) Are DTT and sonication more sensitive and/or more specific than standard cultures of tissue samples for the diagnosis of PJI? (2) Which test (DTT or sonication) is more sensitive when the clinician does not suspect infection before surgery? (3) Which test (DTT or sonication) is more sensitive when the clinician suspects infection before surgery? METHODS: Two hundred thirty-two patients undergoing revision of a knee or hip arthroplasty were prospectively evaluated in this randomized study. Cultures were performed on five tissue samples from each patient and on fluid obtained by prosthesis treatment in patients randomly assigned to sonication (117 patients) or DTT (115 patients). The reference standard against which cultures (on tissue samples and on fluids from sonication or DTT) were compared was the Musculoskeletal Infection Society definition of PJI. RESULTS: Cultures on sonication and DTT fluids provided higher sensitivity (89% and 91%, respectively) than those on standard cultures of tissue samples (79%; p < 0.001). Among patients in whom infection was not suspected before surgery, the sensitivity of DTT was greater than that for sonication and cultures on tissue samples (100% versus 70% and 50%; p < 0.001). Among patients in whom infection was suspected before surgery, the sensitivity of DTT and sonication were not greater than that for standard cultures (89% and 94% versus 86%). CONCLUSIONS: In this randomized study, we found no difference in sensitivity between DTT and sonication for the detection of PJI, and both of those tests were more sensitive than standard tissue cultures. Thus, cultures of sonication or DTT fluid should be considered important additional tools to standard cultures for definition of PJI and should be considered together with other criteria, especially in settings where infection is not suspected before revision surgery.Level of Evidence Level I, diagnostic study.
引用
- Sambri A, Cadossi M, Giannini S, et al. Is Treatment With Dithiothreitol More Effective Than Sonication for the Diagnosis of Prosthetic Joint Infection? Clin Orthop Relat Res. 2018. PMID: 29389758. doi:10.1007/s11999.0000000000000060
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。