文献速递关节外科

初次全髋关节置换术的早期失败:手术入路是否为危险因素?

Early Failure of Primary Total Hip Arthroplasty: Is Surgical Approach a Risk Factor?
PubMed 文献 · J Arthroplasty · 2018-02-02

该回顾性研究纳入2007至2014年间某高流量中心连续完成的6894例初次全髋关节置换术(THA),按直接前入路(DAA)与后入路(PA)分层,比较5年内早期翻修率。结果显示DAA组与PA组总体翻修率无统计学差异(1.69% vs 1.39%,P=0.33),但DAA组因股骨假体松动翻修率更高(P=0.0003),PA组因不稳翻修率更高(P=0.04)。

要点

  • DAA组与PA组总体早期翻修率无统计学差异(1.69% vs 1.39%,P=0.33)。
  • DAA组因股骨假体松动翻修的比例高于PA组(35.7% vs 8%,P=0.0003)。
  • PA组因不稳翻修的发生率高于DAA组(P=0.04)。

核心结论

  • DAA组股骨松动发生率更高,PA组因不稳失败的比例更高,但两种入路的总体翻修率无统计学差异。

研究设计与样本

  • 回顾性综述,纳入2007至2014年某高流量中心连续完成的初次THA,仅纳入DAA与PA两种入路,主要结局为5年内早期翻修。

主要发现

  • 共纳入6894例初次THA,其中DAA组2431例、PA组4463例,总体翻修103例。
  • DAA组总体翻修率为1.69%,PA组为1.39%,两组无统计学差异(P=0.33)。
  • DAA组因股骨假体松动翻修的比例为35.7%,PA组为8%,差异有统计学意义(P=0.0003)。
  • DAA入路在Dorr A型骨中因股骨松动导致的早期失败更常见(P=0.03)。
  • PA组因不稳翻修的发生率更高(P=0.04)。

关键数值与推荐

  • 早期翻修定义为5年内翻修。
  • DAA组总体翻修率1.69% vs PA组1.39%(P=0.33)。
  • DAA组股骨松动翻修比例35.7% vs PA组8%(P=0.0003)。
  • DAA组Dorr A型骨因股骨松动早期失败更常见(P=0.03)。
  • PA组因不稳翻修发生率更高(P=0.04)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In an era of innovation in surgical approaches for total hip arthroplasty (THA), there is concern for increasing trends of early failure. The purpose of this study is to evaluate the incidence of early failure of primary THA stratified by surgical approach. METHODS: A retrospective review was performed on consecutive primary THAs completed from 2007 to 2014 at a high-volume center. THAs were stratified by surgical approach. Only the direct anterior (DAA) and posterior approaches (PA) were included. The primary outcome measure was early revision (<5 years). Descriptive statistics were performed using SAS software. RESULTS: In total, 6894 primary THAs performed between 2007 and 2014 were included. Across 2431 DAA THAs and 4463 PA THAs, there were 103 revisions overall. There was no difference in the overall revision rate for DAA THAs (1.69%) compared to PA THAs (1.39%) (P = .33). The DAA had a higher rate of early revisions for femoral component loosening compared to the PA (P = .0003). About 35.7% of DAA THAs were revised for femoral loosening compared to 8% for the PA (P = .0003). Early failure by femoral loosening occurred more often via the DAA in Dorr A bone (P = .03). The PA had a higher incidence of revision for instability (P = .04). There was no difference in modes of failure with regards to time to failure, acetabular loosening, early periprosthetic fracture, or infection. CONCLUSION: The DAA had a higher incidence of femoral loosening while PA had a higher mode of failure due to instability. Overall revision rates were not statistically different between approaches.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Angerame MR, Fehring TK, Masonis JL, et al. Early Failure of Primary Total Hip Arthroplasty: Is Surgical Approach a Risk Factor? J Arthroplasty. 2018. PMID: 29439894. doi:10.1016/j.arth.2018.01.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。