脊柱侧凸手术中导航与徒手技术相比增加辐射但未提高椎弓根螺钉准确性
本研究比较了49例特发性脊柱侧凸患者后路脊柱融合术中,术中三维影像导航与徒手技术置入椎弓根螺钉的准确性和辐射剂量。导航组27例451枚螺钉,徒手组22例384枚螺钉,两组螺钉正确置位比例均为96%(p=0.518),但导航组患者平均辐射剂量更高(1071±447 mGy-cm vs 391±53 mGy-cm,p<0.001)。
要点
- 导航组与徒手组螺钉正确置位比例均为96%,差异无统计学意义(p=0.518)。
- 导航组平均辐射剂量1071±447 mGy-cm,徒手组391±53 mGy-cm,导航组更高(p<0.001)。
- 3级椎弓根螺钉穿破仅见于徒手组,且均位于上胸椎。
核心结论
- 在中度特发性脊柱侧凸初次手术患者中,未观察到基于CT的导航置入椎弓根螺钉的获益,但患者接受的辐射更多。
研究设计与样本
- 2014年至2016年间,49例特发性脊柱侧凸患者由两位外科医生行后路脊柱融合全椎弓根螺钉固定,交替使用徒手技术和导航技术置入螺钉,形成导航组27例451枚螺钉和徒手组22例384枚螺钉。
- 两组在年龄、性别或畸形程度上无差异。
- 由未参与治疗的两位观察者评估螺钉位置,根据术中获得的3-D O-arm扫描进行分级:0级为无椎弓根壁破坏;1级为穿孔≤2 mm;2级为2至4 mm;3级为穿孔>4 mm;0级和1级视为位置正确,2级和3级视为位置错误。
- 证据等级为III级,治疗性研究。
主要发现
- 导航组和徒手组螺钉正确置位的比例均为96%(p=0.518)。
- 3级椎弓根螺钉仅见于徒手组,且均位于上胸椎。
- 导航组患者接受的辐射剂量高于徒手组(1071±447 mGy-cm vs 391±53 mGy-cm;平均差680 mGy-cm;95%CI 217-2053 mGy-cm;p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The clinical value of pedicle screws in spinal deformity surgery is well known; however, screw insertion is demanding and sometimes associated with complications. Navigation systems based on intraoperatively obtained three-dimensional (3-D) images were developed to minimize pedicle screw misplacements. However, there is a lack of data confirming superiority of navigation above other techniques. There are also concerns regarding increased radiation used during the procedure. QUESTIONS/PURPOSES: The purposes of this study were (1) to compare accuracy of the two methods of pedicle screws placement: intraoperative 3-D image navigation versus a freehand technique in patients with idiopathic scoliosis; and (2) to assess the radiation dose received by patients with both methods. METHODS: Between 2014 and 2016, 49 patients underwent posterior spinal fusion with all pedicle screw constructs for idiopathic scoliosis performed by two surgeons. The study design involved alternating the use of the freehand technique and navigation to position pedicle screws in consecutive patients, forming groups of 27 patients with 451 navigated screws and 22 patients with 384 screws positioned freehand. The two groups did not differ in age, sex, or magnitude of deformity. Two observers not involved in the treatment evaluated the position of the screws. The pedicle breach was assessed on intraoperatively obtained 3-D O-arm® scans according to a grading system: Grade 0 = no pedicle wall violation; Grade 1 = perforation ≤ 2 mm; Grade 2 = 2 to 4 mm; and Grade 3 = perforation > 4 mm. Grades 0 and 1 were considered properly positioned and Grades 2 and 3 represented malposition. RESULTS: In terms of accuracy, we found no differences, with the numbers available, between the freehand and navigated groups in terms of the proportion of screws that were properly positioned (96% freehand and 96% in the navigation group, respectively; p = 0.518). Grade 3 pedicle screws were observed only in the freehand group and were all located in the upper thoracic spine. Patients undergoing navigated pedicle screw placement received a greater mean radiation dose than those whose screws were placed freehand (1071 ± 447 mGy-cm versus 391 ± 53 mGy-cm; mean difference, 680 mGy-cm; 95% confidence interval, 217-2053 mGy-cm; p < 0.001). CONCLUSIONS: In patients with moderate idiopathic scoliosis undergoing primary surgery, we did not observe benefits of pedicle screw placement with CT-based navigation, but the patients experienced greater exposure to radiation. LEVEL OF EVIDENCE: Level III, therapeutic study.
引用
- Urbanski W, Jurasz W, Wolanczyk M, et al. Increased Radiation but No Benefits in Pedicle Screw Accuracy With Navigation versus a Freehand Technique in Scoliosis Surgery. Clin Orthop Relat Res. 2018. PMID: 29432262. doi:10.1007/s11999.0000000000000204
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。