文献速递关节外科小儿骨科

Crowe III型发育性髋关节发育不良患者骨量的计算机断层扫描评估:对高位髋中心技术指导髋臼假体放置的意义

Computed Tomographic Evaluation of Bone Stock in Patients With Crowe Type III Developmental Dysplasia of the Hip: Implications for Guiding Acetabular Component Placement Using the High Hip Center Technique.
PubMed 文献 · J Arthroplasty · 2017-10-24

本研究利用髋关节CT和图像处理软件对20例Crowe III型发育性髋关节发育不良髋进行数字重建,模拟假体在不同前倾角(0°、5°、10°)下从解剖髋中心垂直上移,计算髋臼假体覆盖率和边缘接触率。结果显示覆盖率与前倾角组别在原生旋转中心分别为65.87%、67.77%、68.98%,上移25 mm时增至86.45%、85.85%、84.71%;边缘接触率分别为49.17%、50.25%、51.92%,上移22.5 mm时增至86.87%、86.39%、84.94%。覆盖率和边缘接触率正相关(r=0.687、0.683、0.645,P<.001)。结论认为CT分析和计算机模拟表明在Crowe III型髋中使用高位髋中心技术是可行的。

要点

  • 模拟假体从解剖髋中心垂直上移,覆盖率在25 mm处达86.45%、85.85%、84.71%(前倾角0°、5°、10°组)。
  • 边缘接触率在22.5 mm处达86.87%、86.39%、84.94%(前倾角0°、5°、10°组)。
  • 覆盖率和边缘接触率正相关(r=0.687、0.683、0.645,P<.001)。

核心结论

  • CT分析和计算机模拟表明在Crowe III型髋中使用高位髋中心技术是可行的。

研究设计与样本

  • 利用髋关节CT和图像处理软件对20例Crowe III型发育性髋关节发育不良髋进行数字重建。
  • 模拟假体分别以0°(I组)、5°(II组)、10°(III组)前倾角放置,每组先从解剖髋中心开始,再以2.5 mm为步长垂直上移至40 mm。

主要发现

  • 在原生旋转中心,覆盖率在I组、II组、III组分别为65.87%、67.77%、68.98%,上移25 mm时增至86.45%、85.85%、84.71%。
  • 在原生旋转中心,边缘接触率在I组、II组、III组分别为49.17%、50.25%、51.92%,上移22.5 mm时增至86.87%、86.39%、84.94%。
  • 覆盖率和边缘接触率正相关(0°时r=0.687,5°时r=0.683,10°时r=0.645;P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We evaluated acetabular cup coverage (CC) and rim contact (RC) to evaluate the bone stock above the acetabulum for guiding acetabular component placement using the high hip center technique in patients with Crowe type III developmental dysplasia of the hip. METHODS: Using hip computed tomography and image processing software, pelvises were reconstructed digitally in 20 hips with Crowe type III developmental dysplasia of the hip. Mimicked cup was placed with anteversion angles of 0° (group I), 5° (group II), and 10° (group III) respectively. In each group, the cup was placed at the anatomical hip center at first, and then the cup was moved up to 40 mm vertically about the native rotation center with an increment of 2.5 mm at each step. CC and RC were calculated and documented with each movement. RESULTS: CC was 65.87%, 67.77%, and 68.98% for group I, group II, and group III at the native rotation center, and increased progressively to 86.45%, 85.85%, and 84.71% at 25 mm above. RC was 49.17%, 50.25%, and 51.92% for group I, group II, and group III at the native rotation center, and increased progressively to 86.87%, 86.39%, and 84.94% at 22.5 mm above. CC and RC were positively correlated, despite the different anteversion angles (r = 0.687 at 0°, 0.683 at 5°, and 0.645 at 10°; P < .001). CONCLUSION: Computed tomography analysis and computer stimulation demonstrate that it is feasible to use high hip center technique in Crowe type III hips.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Liu B, Gao YH, Ding L, et al. Computed Tomographic Evaluation of Bone Stock in Patients With Crowe Type III Developmental Dysplasia of the Hip: Implications for Guiding Acetabular Component Placement Using the High Hip Center Technique. J Arthroplasty. 2017. PMID: 29129617. doi:10.1016/j.arth.2017.10.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。