采用新型髋臼植入物联合打压植骨与骨水泥杯行髋关节翻修术的2至16年临床随访
回顾性分析170例髋臼翻修术,采用打压植骨联合 graft-compressing 钛壳植入物,随访7年(标准差2.8)。5例(3%)因机械性松动再手术,10年生存率92%,Merle d'Aubigne-Postel评分从术前10.8升至末次随访16.4,临床与影像学结果优良。
要点
- 170例髋臼翻修中,5例(3%)因机械性松动再手术,1例无症状松动未翻修。
- 10年以任何原因再手术为终点的生存率为92%。
- Merle d'Aubigne-Postel评分从术前10.8提高至随访时16.4。
核心结论
- 打压植骨联合 graft-compressing 钛壳植入物在这一复杂病例中获得了优良结果。
研究设计与样本
- 回顾性分析170例髋臼翻修术,随访7年(标准差2.8),采用打压植骨联合 graft-compressing 钛壳植入物。
- 170例中74例为腔隙性骨缺损,93例为节段合并腔隙性骨缺损,3例为骨盆分离。
- 3例失访,33例死亡病例查阅病历以了解再手术情况。
主要发现
- 5例(3%)因机械性松动再手术,另1例评估为松动但无症状且未计划翻修。
- 3例因复发性脱位再手术,2例因深部感染再手术,1例因技术错误再手术。
- 以任何原因再手术为终点,10年生存率为92%。
- Merle d'Aubigne-Postel髋关节评分从术前10.8提高至随访时16.4。
- 临床与影像学结果优良,并评估了植骨整合及髋关节旋转中心矫正情况。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Treatment of acetabular bone loss with impaction bone grafting (IBG) at revision total hip arthroplasty is highly dependent on mechanical stability and graft compression for clinical success. Here, we describe a new technique to further compress and stabilize the acetabular graft bed with a thin, perforated titanium shell. METHODS: We retrospectively analyzed 170 cases of acetabular revision arthroplasty 7 years (standard deviation 2.8) after IBG combined with a graft-compressing titanium shell implant. The patients were reviewed by clinical score and radiography. Three patients were lost to follow-up. The medical journals of the 33 deceased cases were reviewed for any reoperation. Of the 170 cases, 74 had a cavitary acetabular bone defect, 93 had combined segmental and cavitary bone defects, and 3 had a pelvic dissociation. Bone graft incorporation was assessed and correction of the hip center of rotation was calculated. RESULTS: Five cases (3%) were reoperated for mechanical loosening. One more was assessed as loose but asymptomatic and was not planned for revision. There were 3 reoperations for recurrent dislocation, 2 for deep infection and 1 for technical error. Reoperation for any reason, as the end point of survivorship, showed a survival rate of 92% after 10 years. Hip score according to Merle, d'Aubigne, and Postel increased from 10.8 (preoperatively) to 16.4 at follow-up. The clinical and radiological results were excellent. CONCLUSION: IBG combined with the compressing shell results in excellent results for this challenging condition.
引用
- Stigbrand H, Gustafsson O, Ullmark G, et al. A 2- to 16-Year Clinical Follow-Up of Revision Total Hip Arthroplasty Using a New Acetabular Implant Combined With Impacted Bone Allografts and a Cemented Cup. J Arthroplasty. 2017. PMID: 29153632. doi:10.1016/j.arth.2017.10.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。