文献速递关节外科

新型内侧保留间隙技术下后交叉韧带保留型与后稳定型全膝关节置换术的术中软组织平衡比较

Comparison of Intraoperative Soft Tissue Balance Between Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty Performed by a Newly Developed Medial Preserving Gap Technique.
PubMed 文献 · J Arthroplasty · 2017-10-12

本研究比较了采用新型内侧保留间隙技术行后交叉韧带保留型(CR)与后稳定型(PS)全膝关节置换术(TKA)的术中软组织平衡。70例CR-TKA与70例PS-TKA在内翻型骨关节炎患者中实施,测量0°至135°各屈膝角度的关节组件间隙及内/外侧间室间隙。结果显示CR-TKA与PS-TKA的内侧间室间隙无显著差异,PS-TKA在屈膝30°至60°时外侧间室间隙显著大于CR-TKA(P < .05),内侧关节松弛度无显著差异且各角度均在1 mm以内。结论认为PS-TKA采用该技术可获得与CR-TKA相当的内侧稳定性。

要点

  • CR-TKA与PS-TKA从伸直至深度屈膝的内侧间室间隙无显著差异。
  • PS-TKA在屈膝30°至60°时外侧间室间隙显著大于CR-TKA(P < .05)。
  • 内侧关节松弛度两组无显著差异,各屈膝角度均在1 mm以内。

核心结论

  • PS-TKA采用内侧保留间隙技术可获得与CR-TKA相当的内侧稳定性。

研究设计与样本

  • 研究纳入70例CR-TKA与70例PS-TKA,均为内翻型骨关节炎患者,采用新型内侧保留间隙技术并在张力器测量引导下手术。
  • 术中在股骨试模组件就位、髌股关节复位状态下,使用Offset Repo-Tensor在40 lbs关节牵张力下测量0°(完全伸直)、10°(伸直)、30°、45°、60°、90°(屈曲)、120°和135°(深度屈曲)的关节组件间隙及内翻/外翻韧带平衡(内翻角度)。
  • 根据测量的关节组件间隙和内翻韧带平衡计算各屈膝角度的内侧间室间隙(MCG)、外侧间室间隙及内侧关节松弛度(MCG减去聚乙烯衬垫厚度),并比较CR-TKA与PS-TKA。

主要发现

  • 从伸直至深度屈曲,CR-TKA与PS-TKA的内侧间室间隙无显著差异。
  • PS-TKA在屈膝30°至60°时的外侧间室间隙显著大于CR-TKA(P < .05)。
  • 内侧关节松弛度在CR-TKA与PS-TKA之间无显著差异,从伸直至屈曲各角度均在1 mm以内。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Medial stability of the knee is considered to be associated with good clinical results after total knee arthroplasty (TKA). This study aimed to compare intraoperative soft tissue balance between cruciate-retaining (CR) and posterior-stabilized (PS) TKA performed by a newly developed medial preserving gap technique, which aimed at preserving medial stability throughout the range of motion. METHODS: Seventy CR-TKAs and 70 PS-TKAs were performed in patients with varus type osteoarthritis with the novel technique guided by tensor measurements. Final intraoperative soft tissue balance with femoral trial component in place and patellofemoral joint reduced, including the joint component gap and varus/valgus ligament balance (varus angle), with the knee at 0° (full extension), 10° (extension), 30°, 45°, 60°, 90° (flexion), 120°, and 135° (deep flexion), was measured with Offset Repo-Tensor under 40 lbs of joint distraction force. The medial compartment gap (MCG), lateral compartment gap, and medial joint looseness (MCG-polyethylene insert thickness) at each flexion angle were calculated from the measured joint component gap and varus ligament balance, and compared between CR-TKA and PS-TKA. RESULTS: The MCGs from extension to deep flexion of the knee showed no significant differences between CR-TKA and PS-TKA. The lateral compartment gaps in PS-TKA from 30° to 60° of knee flexion was significantly larger than those in CR-TKA (P < .05). Medial joint looseness showed no significant differences between CR-TKA and PS-TKA which is consistent within 1 mm from extension to flexion of the knee. CONCLUSION: PS-TKA similarly achieved medial stability comparable to CR-TKA using the medial preserving gap technique.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tsubosaka M, Muratsu H, Takayama K, et al. Comparison of Intraoperative Soft Tissue Balance Between Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty Performed by a Newly Developed Medial Preserving Gap Technique. J Arthroplasty. 2017. PMID: 29103777. doi:10.1016/j.arth.2017.09.070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。