文献速递关节外科

非骨水泥型围磷灰石涂层与骨水泥型全膝关节置换术的固定与临床结局:采用放射立体测量分析(RSA)的随机对照试验五年随访

Fixation and clinical outcome of uncemented peri-apatite-coated versus cemented total knee arthroplasty : five-year follow-up of a randomised controlled trial using radiostereometric analysis (RSA).
PubMed 文献 · Bone Joint J · 2017-01-01

该随机对照试验将60例全膝关节置换术患者分为围磷灰石(PA)涂层非骨水泥型组与骨水泥型组,各30例,采用放射立体测量分析(RSA)评估胫骨组件迁移。五年随访时,PA涂层组总体迁移显著大于骨水泥组(p=0.003),但术后3个月至5年间骨水泥组迁移显著更大(p=0.02);临床结局两组无显著差异。

要点

  • 五年随访时,PA涂层组胫骨组件平均最大总点运动(MTPM)为0.97 mm(95%CI 0.81至1.15),骨水泥组为0.62 mm(95%CI 0.49至0.76),PA涂层组总体迁移显著更大(p=0.003)。
  • 术后3个月至5年间,骨水泥组MTPM为0.27 mm(95%CI 0.19至0.36),PA涂层组为0.13 mm(95%CI 0.01至0.25),骨水泥组迁移显著更大(p=0.02)。
  • 两组临床结局无显著差异;每组各有一枚假体因五年随访期间持续迁移被认为存在无菌性松动风险。

核心结论

  • PA涂层非骨水泥型胫骨组件总体迁移大于骨水泥型胫骨组件,但事后分析显示该差异源于PA涂层组件在术后前3个月迁移较高,之后迁移模式稳定。
  • 临床结局两组无显著差异。

研究设计与样本

  • 随机对照试验,患者随机分配至PA涂层非骨水泥型或骨水泥型全膝关节置换术组。
  • 共60例患者(每组30例),以胫骨组件迁移的放射立体测量分析(RSA)为主要结局,评估时间点为基线、术后3个月及术后1年、2年、5年。
  • 采用线性混合效应模型分析重复测量数据。

主要发现

  • 五年随访时,骨水泥组胫骨组件平均MTPM为0.62 mm(95%CI 0.49至0.76),PA涂层组为0.97 mm(95%CI 0.81至1.15),PA涂层组总体迁移显著更大(p=0.003)。
  • 术后3个月至5年间,骨水泥组MTPM为0.27 mm(95%CI 0.19至0.36),PA涂层组为0.13 mm(95%CI 0.01至0.25),骨水泥组迁移显著更大(p=0.02)。
  • 五年随访期间,骨水泥组有1枚组件因韧带不稳而翻修。
  • 每组各有1枚假体因五年随访期间持续迁移被认为存在无菌性松动风险,但两组迁移模式不同:PA涂层组件初始迁移较高但随时间减小,骨水泥组件迁移逐渐增加。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The optimal method of tibial component fixation remains uncertain in total knee arthroplasty (TKA). Hydroxyapatite coatings have been applied to improve bone ingrowth in uncemented designs, but may only coat the directly accessible surface. As peri-apatite (PA) is solution deposited, this may increase the coverage of the implant surface and thereby fixation. We assessed the tibial component fixation of uncemented PA-coated TKAs versus cemented TKAs. PATIENTS AND METHODS: Patients were randomised to PA-coated or cemented TKAs. In 60 patients (30 in each group), radiostereometric analysis of tibial component migration was evaluated as the primary outcome at baseline, three months post-operatively and at one, two and five years. A linear mixed-effects model was used to analyse the repeated measurements. RESULTS: After five years of follow-up, one (cemented) component was revised due to ligament instability. Overall, uncemented PA-coated tibial components migrated significantly more (p = 0.003), with the mean maximum total point motion (MTPM) at five years being 0.62 mm (95% confidence intervals (CI) 0.49 to 0.76) for cemented tibial components and 0.97 mm (95% CI 0.81 to 1.15) for PA-coated tibial components in TKA. However, between three months and five years the cemented TKAs migrated significantly more (p = 0.02), displaying a MTPM of 0.27 mm (95% CI, 0.19 to 0.36) versus 0.13 mm (95% CI, 0.01 to 0.25) for PA-coated tibial components. One implant in each group was considered at risk for aseptic loosening due to continuous migration after five years of follow-up, albeit with different migration patterns for each group (i.e. higher initial migration but diminishing over time for the PA-coated component versus gradually increasing migration for the cemented component). CONCLUSION: The tibial components of PA-coated TKAs showed more overall migration compared with the tibial components of cemented TKAs. However, post hoc analysis showed that this difference was caused by higher migration of PA-coated components in the first three months, after which a stable migration pattern was observed. Clinically, there was no significant difference in outcome between the groups. Cite this article: Bone Joint J 2017;99-B:1467-76.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. van Hamersveld KT, Marang-van de Mheen PJ, Tsonaka R, et al. Fixation and clinical outcome of uncemented peri-apatite-coated versus cemented total knee arthroplasty : five-year follow-up of a randomised controlled trial using radiostereometric analysis (RSA). Bone Joint J. 2017. PMID: 29092985. doi:10.1302/0301-620X.99B11.BJJ-2016-1347.R3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。