文献速递关节外科创伤骨科

非骨水泥锥形楔形柄长度影响直接前入路全髋关节置换术假体周围股骨骨折风险

Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-10-06

该回顾性研究评估了686例(851髋)经直接前入路行初次全髋关节置换术并使用同款非骨水泥锥形楔形柄(短柄或标准柄)的患者,发现假体周围股骨骨折发生率为2.0%,其中术中骨折1.2%、术后早期骨折0.8%。短柄的骨折发生率显著高于标准柄,多因素logistic回归显示仅柄长度与假体周围骨折显著相关。

要点

  • 短柄非骨水泥锥形楔形柄的假体周围股骨骨折发生率显著高于标准柄。
  • 多因素logistic回归显示,仅柄长度是假体周围股骨骨折的独立预测因素。
  • 总体假体周围股骨骨折发生率为2.0%,其中术中1.2%、术后0.8%。

核心结论

  • 结果表明柄设计影响假体周围股骨骨折风险。

研究设计与样本

  • 回顾性评估686例(851髋)经直接前入路行初次全髋关节置换术并使用同款非骨水泥锥形楔形柄(短柄或标准柄)患者的病历资料。
  • 所有髋均采用标准手术台上的直接前入路。
  • 采用多因素logistic回归分析识别术中及术后早期假体周围骨折的独立预测因素。

主要发现

  • 共观察到17例假体周围股骨骨折(2.0%),包括10例术中骨折(1.2%)和7例术后骨折(0.8%)。
  • 短柄的骨折发生率显著高于标准柄。
  • 多因素logistic回归分析显示,仅柄长度与假体周围骨折显著相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although the popularity of the direct anterior approach for total hip arthroplasty has increased, the femoral procedure in this approach is considered technically challenging, and one of the most frequent complications reported was periprosthetic femoral fractures. The present study aimed to identify factors for predicting the risk of periprosthetic femoral fractures after using stems with a cementless tapered-wedge design through the direct anterior approach. METHODS: We retrospectively assessed the medical records of 686 patients (851 hips) who underwent primary total hip arthroplasty using a single stem with a cementless tapered-wedge design having a short or standard length option. The direct anterior approach on a standard operating table was used for all hips. Multivariate logistic regression analysis was performed to identify the independent predictors of intraoperative and early postoperative periprosthetic fractures. RESULTS: Seventeen periprosthetic femoral fractures (2.0%) were observed, including 10 intraoperative (1.2%) and 7 postoperative (0.8%) fractures. The occurrence rate of fractures using short stems was significantly higher compared with that using standard stems. The multivariate logistic regression analysis revealed that only stem length was significantly associated with periprosthetic fractures. CONCLUSION: Our results indicate that the stem design affects the risk of periprosthetic femoral fractures.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tamaki T, Jonishi K, Miura Y, et al. Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 29107490. doi:10.1016/j.arth.2017.09.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。