手术室人员流动增加气溶胶颗粒并损害空气质量:一项模拟研究

Operating Room Traffic Increases Aerosolized Particles and Compromises the Air Quality: A Simulated Study.
PubMed 文献 · J Arthroplasty · 2017-10-16

这项模拟研究在关节置换单元空置手术室内,分别开启和关闭层流空气流(LAF)系统,测试9人每15分钟依次进入以及每分钟开门次数从0递增至4对空气中颗粒密度的影响。结果显示人员数和开门频率均与颗粒密度相关,开启LAF可显著削弱这两种关系。

要点

  • 手术室人员数和每分钟开门次数与空气颗粒密度相关。
  • 开启LAF后,每增加一人所致颗粒密度从211.19降至18.19颗粒/ft³(P < .001)。
  • 开启LAF后,每分钟开门所致颗粒密度从117.80降至1.90颗粒/ft³(P = .017)。

核心结论

  • 本研究证实手术室人员流动和开门是手术室空气颗粒的主要来源。
  • 控制人员流动对减少颗粒至关重要,可能是降低假体周围关节感染的关键预防策略。
  • LAF对人员数和开门带来的负面影响具有保护作用。

研究设计与样本

  • 模拟研究,在关节置换单元配备LAF系统的空置手术室内进行两组实验。
  • 第一组实验:9人每15分钟进入一人,用颗粒计数仪计数空气中颗粒数。
  • 第二组实验:开门频率从每分钟0次开始,以15分钟为增量递增至每分钟4次。
  • 两组实验均在LAF开启和关闭条件下各进行一次。

主要发现

  • 手术室人员数和每分钟开门次数均与颗粒密度相关。
  • 开启LAF后上述两种关系均显著减弱,相关系数<0.4。
  • LAF开启时,每增加一人所致颗粒密度从211.19降至18.19颗粒/ft³(P < .001)。
  • LAF开启时,每分钟开门所致颗粒密度从117.80降至1.90颗粒/ft³(P = .017)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Strategies to prevent bacterial fallout and reduce particle count in the operating room (OR) are key components of preventing periprosthetic joint infection. Although OR traffic control is an important factor, a quantitative study has not been performed to investigate the influence of personnel and door opening on OR air quality. This simulated study aimed to examine the influence of these 2 factors on particle density in OR with and without the laminar air flow (LAF). METHODS: Both experiments took place within an empty OR of an arthroplasty unit equipped with an LAF system. First, the number of particles in the air was counted using a particle counting apparatus while 9 persons entered the room, one every 15 minutes. Second, the door was opened and closed starting with zero door openings per minute and increasing to 4 in 15-minute increments. Both experiments were performed once with the LAF turned on and once without. RESULTS: The number of personnel in the OR and the number of door openings per minute correlate with the density of particles. Both relationships were significantly reduced by turning the LAF on (correlation coefficients <0.4). With the LAF being turned on, the particle density per person decreased from 211.19 to 18.19 particles/ft3 (P < .001) and the particle density per rate of door openings declined from 117.80 to 1.90 particles/ft3 (P = .017). CONCLUSION: This study confirms that personnel and door opening are a major source of particles in the OR air. Controlling traffic is critical for reduction of particles and is likely to be a key preventative strategy in reducing periprosthetic joint infection. LAF is protective against the negative influence of number of people and door openings.

来源:J Arthroplasty,查看原文。版权归原作者所有。